Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add filters








Year range
1.
Journal of Dentistry-Shiraz University of Medical Sciences. 2014; 15 (1): 6-14
in English | IMEMR | ID: emr-180884

ABSTRACT

Statement of Problem: Reattachment of the fractured tooth fragment should be considered as a conservative treatment and valid alternative to a composite restoration.


Purpose: This in vitro study was to evaluate the influence of different adhesives and composite resins on fracture resistance of dental fragment reattached to sectioned incisal edges


Materials and Method: 120 sound human maxillary central incisors were selected under standard conditions and randomly divided into 3 groups, 12 sound teeth were used as a control group and the remaining teeth were assigned to 3 groups [n=36] and each group into three subgroups [n=12]. The incisal third of samples was sectioned using a diamond disk and the respective fragments were then reattached utilizing different intermediate restorative materials, namely: i] adhesive materials alone [OptiBond S or OptiBond XTR or OptiBond All-in-One; ii] Premise flowable composite and iii] Point 4 composite in the one of mentioned adhesive interface. After storage for two weeks at 37°C and 100% humidity and then thermocycling; shear bond strength [SBS] was recorded in kilogram force [kgf] by applying a load in the middle incisal third with a Zwick Universal Testing Machine at a cross-head speed of 1 mm/min. Data was analyzed with one-way ANOVA and Tukey HSD [p< 0.05]


Results: The control group had a significantly higher SBS than other groups [p= 0.001]; the highest SBS values was obtained using the premise flowable composite and OptiBond S adhesive [112.44 +/- 30.46 Mpa]; and the lowest with OptiBond All-in-One alone [33.97 +/- 15.63 Mpa]


Conclusion: Although, none of the tested materials provided fracture resistance similar to that found with the intact maxillary central incisors; utilizing the premise flowable composite and OptiBond S adhesive improved the SBS of the reattached fragment than other materials

2.
Journal of Dentistry-Shiraz University of Medical Sciences. 2010; 11 (1): 28-34
in Persian | IMEMR | ID: emr-129465

ABSTRACT

Bonded restorations have a number of advantages over traditional, non-adhesive methods. Adhesion reduces the microleakage at the restoration-tooth interface. Prevention of microleakage, or the ingress of oral fluids and bacteria along the cavity wall, reduces the clinical problems such as postoperative sensitivity, marginal staining, and recurrent caries, all of which may jeopardize the clinical longevity of restorative efforts. The aim of this study was to evaluate the microleakage in class V composite restoration with total-etch and self-etch adhesive systems. In this in-vitro study, 48 standard class V cavities were prepared in the buccal surface of human extracted premolars so that the occlusal margins of the cavities were in the enamel and the gingival margins in the dentin [cementum]. The teeth were divided into two groups of 24. In the first group, the cavities were restored with total-etch system [Excite] and composite. The teeth in the second group were restored with self-etch system [Prompt L-Pop] and the same composite. The teeth were thermocycled 500 times between 5 - 55°C and then were covered with nail-polish and adhesive wax axcept for 1 mm around cavities, and all teeth were immersed into the 2% methylene blue for 10 hours. The samples were mounted in polyester blocks, sectioned longitudinally at the middle of the cavities, and evaluated for microleakage under a stereomicroscope at 40x magnification. Dye penetration was scored between 0-3. Data were analyzed with Mann Whitney and Wilcoxon tests. In the enamel and dentin margins, microleakage for the total-etch group was found to be less than the self-etch group [p < 0.05]. A significant difference in the microleakage mean rank of the enamel and dentin margins was observed [p< 0.05]. Microleakage in the enamel margins was less than that in the dentin margins. Total-etch adhesive system showed a significant difference on the microleakage of class V composite restorations especially in the enamel margin


Subject(s)
Dental Leakage , Dental Bonding
3.
Journal of Qazvin University of Medical Sciences and Health Services [The]. 2009; 13 (3): 23-28
in Persian | IMEMR | ID: emr-97250

ABSTRACT

Polymerization shrinkage is one of the most common causes of microleakage in packable composites. Various methods are recommended to reduce polymerization shrinkage and the application of flowable composites is one of these methods. The aim of the current study was to evaluate the effect of flowable composite on the microleakage of packable resin composite in class II cavities. This experimental study was performed at Dental School of Shahid Sadoughi University, Yazd [Iran] in 2006. On 32 recently extracted upper premolar teeth, the mesial and distal class II cavities with the same dimensions were created. The teeth were randomly assigned into two groups: the distal surfaces of the first group were restored with P60 while in the other group restoration was accomplished with Solitaire resin composite. The mesial aspects of the teeth were filled with Filtekflow flowable composite and other composites mentioned above. After thermocycling, the samples were soaked in 2% methylene blue solution followed by sectioning in mesiodistal direction. The degree of microleakage was evaluated by stereomicroscope with 25 X magnification. Data were subjected to the chi-square and Exact tests, statistically. The flowable composite failed to reduce the degree of microleakage in axial wall and gingival floors [p>0.05]. The application of flowable resin composite caused no effect on microleakage of class II packable resin composite restorations


Subject(s)
Polymers , Dental Caries
4.
Journal of Qazvin University of Medical Sciences and Health Services [The]. 2009; 12 (4): 56-62
in Persian | IMEMR | ID: emr-91856

ABSTRACT

Clinical longevity is a primary concern when selecting a restorative dental material. Clinical failure is the point at which the restoration is no longer useful and may pose sever risks if not replaced. The aim of this clinical study was to evaluate the failure in CL II amalgam restorations in operative department of dental school affiliated to Shahid Sadoughi University of Medical Sciences. This was an analytic-descriptive study performed on 69 patients who were previously treated at Yazd dental school and invited to be reexamined for treated teeth. All Patients [220 teeth] with problems in their amalgam restoration were thoroughly examined under appropriate light. Evaluation criteria were direct observation, probing by explorer, dental floss, and radiography. Patients were requested to fill a questionnaire regarding a number of subjective questions and oral hygiene. Objective observations were overhang 25.5%, secondary caries 15%, improper contact 7.3%, fracture 1.4%, improper anatomic form 3.6%, ditch 3.6%, gap 0.4%, and restoration avulsion 0.5%. Regarding the subjective criteria, problems such as food impaction 13.2%, sensitivity to cold 8.2%, sensitivity to heat 5.9%, sensitivity to pressure 3.2%, gingival discomfort 3.2%, spontaneous pain 2.3%, and poor oral hygiene 15.8% were revealed. Although he difference in failure of amalgam restoration among all study groups was shown to be insignificant however, more strict supervision by dental attending concerning the proper implementation of procedures for an ideal restoration is recommended


Subject(s)
Humans , Dental Amalgam , Treatment Outcome , Schools, Dental , Surveys and Questionnaires , Radiography, Dental , Dental Devices, Home Care , Oral Hygiene , Dental Restoration Failure
5.
Dental Journal-Shahid Beheshti University of Medical Sciences. 2008; 26 (1): 40-46
in Persian | IMEMR | ID: emr-86124

ABSTRACT

One of the most challenging procedures in restorative dentistry is fitting the color of the restoration to the tooth. The main purpose of this study was to determine the ability rate of color matching among the students of Yard faculty of dentistry in December 2004. In this descriptive study, 127 dental clinical students of Yard faculty were participated. Age, gender, wearing eyeglasses or lens and the year of starting the dental faculty were assessed as variable. Heliomolar composite with 16 colors was used to make the shade guide and 6 colors of the same composite were used as test group. The students were matched the shade guide with the test group in similar conditions. The data was analyzed by t, ANOVA and LSD test. Mean truth definition of all colors in 20-29 years old students were 3.86 and in 30-40 years old group were 3.38 and there was no significant differences between them. Mean truth definition in male group was 3.57 and was 3.91 in females. There was no significant differences between them. Mean truth definition in all of the colors by students without eyeglasses or contact lens were 3.98 and the other group was 3.55 which was significantly differences [P=0.023]. The difference between the entrance year for mean truth definition of all colors was significant [P=0.016]. In this study, the students whom specially wear photochoromic eyeglasses or contact lenses were lower truth color definition, but age and gender had no effect on truth color definition


Subject(s)
Humans , Male , Female , Analysis of Variance , Color , Tooth Discoloration , Dental Restoration, Permanent
6.
Journal of Dental Medicine-Tehran University of Medical Sciences. 2007; 19 (4): 32-39
in Persian, English | IMEMR | ID: emr-104687

ABSTRACT

With the introduction of different bondable restorative materials in dentistry, various methods have been suggested to enhance the polymerization and shear bond strength of these materials. The aim of this study was to determine the effects of different methods of enamel conditioning on bond strength of orthodontic brackets and on the bracket/ adhesive failure mode. In this experimental in vitro study, brackets were bonded to thirty-six bovine incisor teeth with different protocols according to the manufacturer's instructions as follows: Group 1: conventional multistep adhesive [n=12]; Group 2: self-etching primer system [n=12]; Group 3: acid+self-etching primer system [n=12]. Specimens were loaded in a universal testing machine [Instron, Canton and Mass] and the mode of failure was recorded. Data were analyzed by ANOVA and Kruskall-Wallis tests with p<0.05 as the limit of significance. The mean shear bond strength was 11.7 +/- 4.2, 10.5 +/- 4.4, and 10.9 +/- 4.8 MPa for group 1, 2, and 3 respectively. There was no significant difference in bond strength among the three groups [P=0.800]. No significant difference was observed among the three groups with respect to residual adhesive on the enamel surfaces [P=0.554]. Based on the results of the present study, the use of self-etching primers may be an alternative to conventional phosphoric acid pre-treatment in orthodontic bonding


Subject(s)
Animals , Dental Enamel , Dental Cements , Dental Bonding , Analysis of Variance , Polymethacrylic Acids , Phosphoric Acids , Dentin-Bonding Agents
7.
Journal of Islamic Dental Association of Iran [The]-JIDA. 2007; 19 (2): 14-21
in English, Persian | IMEMR | ID: emr-83435

ABSTRACT

Composite resin restorations are widely used in dentistry. Therefore, it is important to identify possible causes of failures in this regard. The purpose of this study was to investigate the microleakage of two microfiled and hybrid resin composites following the use of 10% carbamide peroxide. In this experimental study, Class V cavities were prepared on the buccal surfaces of 150 human anterior teeth. These teeth were randomly divided into six groups and filled with two microfilled [D-E] and hybrid resin composites [B-C]. The groups B and D were kept in contact with 10% carbamide peroxide for three weeks. Likewise, groups C and E were kept in contact with the same solution for four weeks. The specimens were rinsed and sectioned after being emmersed in 0.5% buffered fushin, and the microleakage was evaluated under stereomicroscope. Kruskal-Wallis and Mann-Whitney tests as well as Hotteling trace were used to determine the significant differences between the groups. In comparison with the control group, composite microleakage was observed in all groups after emerging the samples in 10% carbamide peroxide. Microleakage was lower in the three-week group, when compared with the four-week one. However, the difference was statistically significant in the microfilled group. The microfilled composite restorations should be changed after using carbamide peroxide


Subject(s)
Humans , Urea , Drug Combinations , Dental Leakage/drug therapy , Composite Resins , Tooth Bleaching , Tooth
8.
Journal of Mashhad Dental School. 2007; 31 (3): 189-194
in Persian | IMEMR | ID: emr-83457

ABSTRACT

The appearance of superficial and deep dentin differs and this may affect the bond strength of adhesive system. The aim of this study was to evaluate the shear bond strength of superficial and deep dentin using self-etch system. This in vitro and experimental study was done on 48 human extracted premolar teeth. After mechanical cleaning, they were disinfected with hypochlorite 5.25% and the roots mounted in acrylic resin. Teeth were divided into 4 groups: A, B, C, D. In A and B groups, buccal surface was reduced until dentino-enamel junction [DEJ]. In C and D groups, buccal surface was reduced 3 mm deeper than DEJ. We used 2 groups of setf-etch systems: Prompt-Lpop and Prime and Bond NT. Prompt-Lpop was used in A and C groups, and Prime and Bond NT was used in B and D, according to their manufacturers' instructions. Pieces of composite with 1.5 mm diameter and 2 mm height were bonded on treated buccal surface of teeth. Finally specimens were loaded to failure in a universal testing machine at a crosshead speed of 1mm/min. The two-way analysis of variance was used for comparing the shear bond strength among the various groups. The mean value of shear bond strength of Prompt-Lpop in superficial dentin was 26.42 +/- 3.40 MPa and in deep dentin was 11.83 +/- 2.62, and of Prime and Bond NT in superfacial dentin was 24.33 +/- 4.70 MPa and in deep dentin was 12.91 +/- 2.21. The mean value of shear bond strength of superficial dentin was 25.37 +/- 4.10 MPa and deep dentin was 12.35 +/- 2.42 Mpa. Statistical analysis of the data showed that there was not a significant difference in shear bond strength between Prompt-Lpop and Prime and Bond NT [P=0.613]. There was a statistically significant difference in shear bond strength between superficial and deep dentin in each self etch system separately. According to data analysis conservative cavity preparation with less depth is recommended for efficient restoration when using self etchant dentin adhesive systems


Subject(s)
Humans , Dentin , Dental Enamel , Organophosphorus Compounds
9.
Journal of Dentistry-Shiraz University of Medical Sciences. 2007; 8 (1): 10-18
in Persian | IMEMR | ID: emr-135182

ABSTRACT

For reducing light exposure time of tooth-colored restorations, and chair time reduction, different experiments have been conducted. The purpose of this study was to determine the effect of different light exposure times to adhesive layers [Excite and Prompt L-pop] on the shear bond strength of dentincomposite interface. In this in-vitro study, 72 human intact premolar teeth were mounted in acrylic casts and enamel buccal surfaces were removed. The bonding surfaces were equalized using a surface index. Teeth were divided into six equal groups each of 12 [A, B, C, D, E, and F]. According to the manufacturer instructions, Excite adhesive in groups A, B and C, and prompt L-pop in groups D, E and F was used. A and D groups were not exposed to light, but the exposure time in groups B, E and C, F was 20s, and 40s respectively. After one week of storage in 37 degree C water, synergy composite resin was applied and then was exposed to light. The specimens were loaded by shear force with 1 mm/min cross head speed. Data were analyzed by two-way analysis of variance [ANOVA]. The means shear bond strength of groups A,B,C,D,E, and F were 3.9, 13.45, 18.1, 8.3, 24.81, 24.99 Mpa, respectively. The differences between shear bond strength of groups A, B and C and between groups B, D were statistically significant [p=0.0001]. However, the differences between groups E, F were not statistically significant. In all exposure times, the bond strength of Prompt L-pop was significantly higher than that of Excite. According to the results of this study, increase in the light exposure led to the higher bond strengths in Excite groups. In Prompt L-pop groups, 20s exposure time was adequate and by increasing the light exposure time, shear bond strength was not affected. Without light exposure in both materials, the least bond strength for the composite resins was not attainable


Subject(s)
Humans , Shear Strength , Dental Cements , Dental Bonding , Composite Resins , Dentin , Bicuspid
10.
Journal of Shaheed Sadoughi University of Medical Sciences and Health Services. 2006; 14 (3): 62-68
in Persian | IMEMR | ID: emr-78174

ABSTRACT

In different investigations, the destructive effect of ultrasonic sealers on the margins of composites has been studied, but there are very few studies on the effects of ultrasonic sealers on the microleakage of poly-acid modified composite resin and resin modified glass ionomers. The main purpose of this study was to evaluate the marginal microleakage of class V preparations restored with resin modified glass ionomer and poly-acid modified composite resin before and after scaling with an ultrasonic sealer. This in vitro study was performed on 160 premolar teeth. Standard class V cavities were prepared on the buccal surfaces of the selected teeth. Occlusal and cervical margins were placed entirely in enamel and cementum, respectively. Teeth were randomly divided to two groups of eighty, each. For one half of each group, [40 teeth] resin modified glass ionomer and for the other half, polyacid modified composite resin was used. Each one of the binary groups was subdivided to two groups. First subgroup was restored with Fuji II Lc [Fuji Japan] and Vitremer [3M USA] and the second subgroup was restored with F[2000] compomer [3M USA] and Compoglass[Vivadent Germany]. For bonding to enamel, dentinte,cementum Singlebond [3M USA] and Adhese 2 [Vivadent Germany] were used and all of the restorations were done according to instructions of the manufacturers. In ten teeth of each group, ultrasonic scaling was done and in the other ten teeth, scaling was not done. After that, all of the teeth were thermocycled and immersed in fuschin. After cutting the microleakage was evaluated. The data was analyzed by Mann - Whitney, Kruskal - Wallis and Wilcoxon tests and significant border was 0.05. The results showed that the degree of microleakage in enamel margins of poly -acid modified resin composites was lower than resin modified glass ionomers and in all groups and subgroups, the microleakage in enamel and cementum after scaling was significantly more than the groups without scaling. Use of resin modified glass ionomers in class V restorations has no advantages over polyacid modified composite resins


Subject(s)
Dental Leakage , Compomers , Glass Ionomer Cements , Ultrasonics
11.
Journal of Dentistry-Shiraz University of Medical Sciences. 2006; 7 (3-4): 114-119
in Persian | IMEMR | ID: emr-128074

ABSTRACT

The electric pulp test [EPT] is an important diagnostic aid in evaluation of pulpal vitality. It was postulated that premedication with analgesics can decrease tooth sensitivity to electric stimulation. The purpose of this study was to evaluate the effect of premeditation with ibuprofen on the responses of vital central teeth to electric pulp tester. This clinical trial study was performed on 88 intact maxillary central and lateral incisors. After taking medical and dental histories and clinical examinations, electric pulp testing was done using tooth paste as conducting medium and the results were recorded. Afterwards, each subject received a 400mg ibuprofen tablet and one hour later, electric pulp testing was conducted again. The data were statistically analyzed using t-test to compare pre- and post-medication records. The mean EPT scale of teeth before ibuprofen administration was 2.5, whereas after drug administration the mean EPT scale of the teeth was 2.7. Statistical analysis showed significant differences. This investigation showed that, although ibuprofen decreased the tooth sensitivity to electrical stimulation, but with proper attention in using pulp tester, it could still be a valuable aid in clinical practice for patient's receiving Ibuprofen

SELECTION OF CITATIONS
SEARCH DETAIL