Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Rev. méd. Chile ; 143(4): 415-423, abr. 2015. ilus, tab
Article in Spanish | LILACS | ID: lil-747546

ABSTRACT

Background: Intracoronary delivery of autologous bone marrow mononuclear cells is an interesting therapeutic promise for patients with heart failure of different etiologies. Aim: To evaluate the long-term safety and efficacy of this therapy in patients with dilated cardiomyopathy of different etiologies under optimal medical treatment. Patients and Methods: Prospective, open-label, controlled clinical trial. Of 23 consecutive patients, 12 were assigned to autologous bone marrow mononuclear cell intracoronary transplantation, receiving a mean dose of 8.19 ± 4.43 x 10(6) CD34+ cells. Mortality, cardiovascular readmissions and cancer incidence rate, changes in functional capacity, quality of life questionnaires and echocardiographic measures from baseline, were assessed at long-term follow-up (37.7 ± 9.7 months) in patients receiving or not the cells. Results: No significant differences were observed in mortality, cardiovascular readmissions or cancer incidence rate amongst groups. An improvement in functional class and quality of life questionnaires in the transplanted group was observed (p < 0.01). The treated group showed a non-significant increase in left ventricular ejection fraction at long-term follow-up (from 26.75 ± 4.85% to 34.90 ± 8.57%, p = 0.059 compared to baseline). There were no changes in left ventricular volumes. We observed no improvement of these variables in the control group. Conclusions: Intracoronary transplantation of autologous bone marrow mononuclear cells is feasible and safe in patients with dilated cardiomyopathy of diverse etiologies. This therapy was associated to persistent improvements in functional class and quality of life. There was also a non-significant long-term improvement of left ventricular function.


Subject(s)
Female , Humans , Male , Middle Aged , Bone Marrow Transplantation/methods , Cardiomyopathy, Dilated/surgery , Bone Marrow Transplantation/mortality , Cardiac Volume/physiology , Cardiomyopathy, Dilated/mortality , Cardiomyopathy, Dilated , Follow-Up Studies , Patient Readmission/statistics & numerical data , Prospective Studies , Quality of Life , Stroke Volume/physiology , Surveys and Questionnaires , Time Factors , Transplantation, Autologous , Treatment Outcome , Ventricular Function/physiology
2.
Rev. chil. cardiol ; 32(1): 11-20, 2013. ilus, tab
Article in Spanish | LILACS | ID: lil-678036

ABSTRACT

Introducción: Estudios recientes indican que el trasplante intracoronario de células mononucleares de médula ósea (BMCs) autólogas, mejoran la fracción de eyección (FEVI) y otros marcadores clínicos en pacientes con insuficiencia cardíaca (IC). Objetivo: Evaluar la seguridad y eficacia de la administración intracoronaria de BMCs autólogas, en pacientes con insuficiencia cardíaca (IC) en fase dilatada, de diferente etiología y en óptimas condiciones de tratamiento médico. Método: De 23 pacientes consecutivos que cumplieron con los criterios de inclusión, 12 fueron asignados a trasplante intracoronario de BMCs autólogas, recibiendo una dosis media de 8.19+/-4.43 x 10(6) células CD34+ (Grupo trasplantado). Los pacientes restantes sólo recibieron terapia estándar (Grupo control). Todos los pacientes fueron evaluados mediante Electrocardiograma, Ecocardiografía, Holter ECG, RMN Cardíaca, Test de esfuerzo, Potenciales Ventriculares Tardíos, Variabilidad de Frecuencia Cardíaca y evaluación clínica a los 0, 3, 6 y 12 meses. La capacidad funcional (CF) fue evaluada clínicamente y por cuestionarios de calidad de vida. Elanálisis estadístico fue realizado mediante Test Anova, y test de Bonferroni. Resultados: El grupo trasplantado presentó un aumento significativo de la FEVI a los 6 meses (26.75+/-4.85 vs 37.82+/-6.97 por ciento, p=0.001) mejoría que se mantuvo a los 12 meses (26.75+/-4.85 vs 37.27+/-7.51 por ciento, p=0.002). Hubo una mejora significativa de la CF en el grupo trasplantado a los 6 y 12 meses (p<0.001). No hubo cambios significativos en los volúmenes de ventrículo izquierdo, así como en las restantes variables estudiadas. En el grupo control no observamos cambios de estas variables. No hubo complicaciones en relación al trasplante de BMCs. Conclusión: En pacientes con IC severa y baja FEVI, el trasplante intracoronario de células BMCs au-tólogas, se asoció a una mejoría significativa de la FEVI y la CF, a los 6 y 12 meses. Adicionalmente, no observamos ...


Background: Recent studies indicate that intra-coronary delivery of autologous bone marrow mono-nuclear cells (BMCs) improves the ejection fraction (LVEF) and other clinical markers in patients with heart failure (HF). Aim: To evaluate the safety and efficacy of intraco-ronary delivery of autologous BMCs in patients with HF in dilated phase under optimal medical treatment. Method: Of 23 consecutive patients who met the inclusion criteria, 12 were assigned to autologous BMCs intracoronary transplantation, receiving a mean dose of 8.19+/-4.43 x 106 CD34+ cells (BMCs group). The remaining patients received only standard therapy (control group). All patients were evaluated by Electrocardiogram, Echocardiography, Holter Monitoring, Cardiac Magnetic Resonance Imaging, Stress Testing, Ventricular Late potetials, Heart Rate Variability, and regular clinical examination at baseline and at follow-up (3, 6 and 12 months). Repeated measures ANOVA and Bonferroni testing were used for statistic analysis. Results: The BMCs group presented a significant increase in EF at sixth months (26.75+/-4.85 vs. 37.82+/-6.97 per cent, p=0.001) and 12 months post-transplant (26.75+/-4.85 vs. 37.27+/-7.51 per cent, p=0.002). There was a significant improvement in functional (NYHA) in the transplanted group at 6 and 12 months (p<0.001). There were no significant changes concerning left ventricular volumes, heart rate variability and exercise stress testing. We observed no improvement of these variables in the control group. There were no complications related to the BMCs transplant. Conclusions: Intracoronary infusion of auto-logous BMCs, in addition to standard therapy, was associated with significant improvement of left ventricular function at 12 months in patients with HF. We observed no complications relative to the procedure.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Bone Marrow Transplantation , Heart Failure/therapy , Ventricular Function , Analysis of Variance , Cardiomyopathy, Dilated/physiopathology , Follow-Up Studies , Single-Blind Method
3.
Rev. chil. cardiol ; 14(4): 209-13, oct.-dic. 1995. graf
Article in Spanish | LILACS | ID: lil-175058

ABSTRACT

En la estenosis aórtica severa (EAS), con función ventricular conservada, se ha sospechado una disfunción autonómica, pero no encontramos en la literatura datos clínicos que la sustenten, pudiendo ser esta condición importante en la generación de arritmias y en la progresión de la cardiopatía de base. La función autonómica fue evaluada por análisis de la variabilidad de la frecuencia cardiaca (VFC) en el dominio tiempo (desviación estándar de la frecuencia cardiaca, DSFC) y en el dominio frecuencia (análisis espectral de la frecuencia cardiaca por análisis de Fourier). Estos resultados se analizaron en un equipo Del Mar Avionics Accu Plus 360. El análisis espectral se dividió en bandas de extrema baja frecuencia (EBF: 0,017 -0,05 Hz), muy baja frecuencia (MBF: 0,05 -0,15 Hz), baja frecuencia (BF: 0,15 -0,35 Hz) y alta frecuencia (AF: 0,35 -0,50 Hz). se estudiaron 7 pacientes con EAS. Edad: 63 ñ 13 años; porcentaje de acortamiento: 30 ñ 11; pared posterior: 12 ñ 2 mm; séptum: 14 ñ 3 mm; gradiente de presión aórtico: 84 ñ 14 mmHg. Todos estaban en ritmo sinusal sin antirrítmicos ni beta bloqueadores. Se compararon con un grupo control de 7 individuos sanos, edad 66 ñ 4 años. Se realizó un ECG continuo de 24 horas, evaluándose respuestas de VFC dominio tiempo y frecuencia en ventanas de 5' tomadas en el momento de máxima frecuencia cardíaca entre las 6-8 AM, 14-16 y 2- AM. En la EAS existió una disminución significativa de la VFC en el dominio del tiempo: DSFC= 53 ñ 6, vs 84 ñ 12 en los controles (p= 0,05). En el dominio frecuencia se observó que en la ventana de tiempo entre las 6 y 8 de la mañana las ondas de extrema y muy baja frecuencia fueron significativamente menores en los pacientes con estenosis aórtica que en el grupo control: 290 ñ 96 vs 22851 ñ 625 (msec²/Hz) para extrema baja frecuencia (P< 0,01) y 192 ñ 51 vs 1296 ñ 967 (msec²/Hz) para muy baja frecuencia (P< 0,05). No se observaron cambios significativos en las ondas de baja y alta frecuencia, como tampoco en las otras ventanas de tiempo. Estos resultados sugieren una disfunción autonómica en la estenosis aórtica que se hace evidente al amanecer y que puede corresponder a una modulaciób autonómica alterada


Subject(s)
Humans , Male , Female , Middle Aged , Aortic Valve Stenosis/physiopathology , Heart Rate/physiology , Case-Control Studies , Circadian Rhythm/physiology , Electrocardiography , Ventricular Function, Left/physiology , Monitoring, Physiologic , Autonomic Nervous System/physiopathology , Spectrum Analysis
SELECTION OF CITATIONS
SEARCH DETAIL