Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Braz. oral res ; 22(2): 151-157, 2008. ilus
Article in English | LILACS | ID: lil-485955

ABSTRACT

This study aimed to present a wireless mandibular motion tracking device and optoelectronic data acquisition system developed to analyze the real-time spatial motion of the entire mandible during mouth opening and closing with no restriction of any movement. The procedures were divided into three phases: confection of a kinematic arch, dynamic digital video image acquisition, and image processing and analysis by using graphic computation. Four sequences of jaw opening/closing movements were recorded in lateral view: two from the maximum intercuspation (MIC) and the other two from a forced mandibular retruded position. Jaw motion was recorded by a digital video camera and processed as spatial coordinates corresponding to the position variation of the markers in the kinematic arch. The results showed that the method was capable of recording and processing the dynamics of the mandibular movements during jaw opening/closing using pixel-magnitude points. The mandible showed points with less displacement located near the temporomandibular joint during the opening/closing movements from the mandibular retruded position. When the jaw movements were recorded from MIC, these points were located near the mandibular foramen.


Subject(s)
Humans , Jaw Relation Record/instrumentation , Jaw/physiology , Mandible/physiology , Temporomandibular Joint Disorders/physiopathology , Temporomandibular Joint/physiopathology , Equipment Design , Image Interpretation, Computer-Assisted , Movement , Orthodontic Appliances
2.
Braz. oral res ; 21(3): 253-258, 2007. tab
Article in English | LILACS | ID: lil-458599

ABSTRACT

There are situations in which intraradicular retainers have to be removed and replaced. The objective of this research was to evaluate the apical seal after the removal of a custom cast post and core with a carbide bur or with an ultrasound apparatus. Twenty five roots of extracted human incisors were used. They were endodontically treated and prepared to receive the posts. The posts and cores were cast with 2 types of dental alloys, CuAlZn and PdAg, and were cemented with zinc phosphate cement. After 24 hours, they were removed using the two above mentioned techniques. Then, the roots had their external surface made impermeable by two layers of cyanoacrylate adhesive, leaving only the cervical area for dye penetration. The teeth were immersed in rhodamine for 24 hours. They were then cut and observed under an optical microscope and analyzed with appropriate software (Imagelab). The results were submitted to ANOVA, and they evidenced that, regarding the alloy factor, PdAg posts presented a larger mean infiltration value (2.23 ± 0.48 mm) as compared to the posts made of CuAlZn (1.39 ± 0.48 mm) (p = 0.025). Regarding the technique factor, there was no significant difference (p = 0.9) between the removal of the intraradicular retainer using ultrasound (1.99 ± 0.62 mm) or using a rotating cutting instrument (1.62 ± 0.62 mm). Under these experimental conditions, it was possible to conclude that the degree of apical leakage was directly related to the alloy type, and it was present in both techniques used.


Há situações que exigem a remoção ou substituição de retentores intra-radiculares. O objetivo deste trabalho foi avaliar o selamento apical do material obturador após a remoção de pino intra-radicular metálico fundido com instrumento cortante rotatório ou com aparelho de ultra-som. Utilizaram-se 25 raízes de incisivos humanos extraídos, que foram endodonticamente tratadas e preparadas para receberem os pinos. Os retentores intra-radiculares foram fundidos com 2 tipos de ligas odontológicas, CuAlZn e PdAg, e foram cimentados com cimento de fosfato de zinco. Após 24 horas, foram removidos com as 2 técnicas citadas. Em seguida, os dentes foram impermeabilizados com cianoacrilato de etila, permitindo a entrada do corante apenas por via cervical. Os dentes foram imersos em rodamina por 24 horas, depois foram clivados e observados em microscópio óptico de luz e analisados em "software" próprio (Imagelab). Os resultados foram submetidos à análise de variância e mostraram que, para o fator liga, os pinos de PdAg geraram uma média de infiltração maior (2,23 ± 0,48 mm) do que os pinos de CuAlZn (1,39 ± 0,48 mm), com p = 0,025; para o fator técnica, não houve diferença significante, com p = 0,9, entre a remoção com ultra-som (1,99 ± 0,62 mm) e a remoção com instrumento cortante rotatório (1,62 ± 0,62 mm). Nestas condições experimentais, foi possível concluir que o grau de infiltração apical está relacionado com o tipo de liga, e a infiltração esteve presente em ambas as técnicas utilizadas.


Subject(s)
Humans , Dental Instruments , Dental Alloys/chemistry , Dental Leakage/etiology , Device Removal/instrumentation , Post and Core Technique/instrumentation , Root Canal Preparation/standards , Analysis of Variance , Post and Core Technique/adverse effects , Root Canal Filling Materials/chemistry , Root Canal Therapy/standards , Tooth Fractures/etiology , Ultrasonics
3.
Ciênc. odontol. bras ; 8(4): 13-17, out.-dez. 2005. ilus, tab
Article in English | LILACS, BBO | ID: biblio-850676

ABSTRACT

Os dentes endodonticamente tratados podem ser restaurados com coroas protéticas cimentadas sobre retentores intra-radiculares metálicos fundidos (RIMF) ou sobre preenchimento retido por pinos pré-fabricados. Clinicamente, verifica-se que, ao longo do tempo, ocorre com freqüência desprendimento da coroa, quando cimentada sobre preenchimento de resina composta. Uma das causas poderia ser a infiltração marginal que as coroas sofrem conforme a variação dos materiais que constituem o núcleo. Dessa forma, determinaram-se três condições experimentais: sete dentes com RIMF, sete dentes totalmente preenchidos com resina composta fotopolimerizável (RC) sobre pino pré-fabricado e sete com remanescente dentinário e preenchimento parcial com a mesma resina composta. Os preparos foram padronizados e moldados. As coroas foram fundidas em NiCr. Após a cimentação com cimento de fosfato de zinco, os corpos de prova foram submetidos à ciclagem térmica e à fadiga mecânica. Em seguida, foram imersos em fuccina básica a 0,05% por 8 horas. Após o seccionamento das coroas, três examinadores aferidos avaliaram visualmente, com lupa de aumento, o grau de infiltração, segundo uma escala de valores. Os dados obtidos foram submetidos à análise de intervalos de confiança, sob nível de 90% de confiança. Concluiu-se que os núcleos de metal fundido comportaram-se de forma semelhante aos núcleos parciais (dentina/RC) com infiltração ao nível cervical e os núcleos totalmente em resina apresentaram maior infiltração, chegando a alcançar o terço médio da parede axial.


Subject(s)
Humans , Male , Female , Composite Resins , Dental Leakage , Post and Core Technique
4.
São Paulo; s.n; 2003. 98 p. ilus, tab. (BR).
Thesis in Portuguese | LILACS, BBO | ID: lil-388500

ABSTRACT

Uma das desvantagens da porcelana dental, além de sua relativa fragilidade, é o seu poder de provocar desgaste excessivo aos dentes naturais ou aos materiais restauradores antagonistas, fato observado clinicamente. Esta propriedade já levou muitos clínicos a contra-indicarem restaurações protéticas utilizando porcelanas. Sabe-se que a qualidade das superfícies das porcelanas dentais nas áreas de contato oclusais é muito importante para reduzir os riscos de agressão aos antagonistas. Para verificar a influência do glazeamento e polimento das porcelanas Ceramco II, Noritake e Finesse na sua abrasividade, este estudo empregou o método radiométrico para medir o desgaste provocado ao esmalte dental humano. As rugosidade média (Ra), dureza Knoop e módulo de elasticidade das porcelanas foram medidas para verificar correlação com o desgaste. Foram utilizadas 5 amostras de esmalte dental e 10 amostras de cada porcelana, sendo 5 glazeadas e 5 polidas. Para uso do método radiométrico, o esmalte dental foi planificado, irradiado com nêutrons do reator nuclear IEA-R1m (IPEN/CNEN) e foi desgastado pelo deslizamento das porcelanas em sua superfície, durante 2500 ciclos para cada porcelana, tendo sido medido o resíduo de esmalte que foi desprendido pelo dente, para cada material antagonista. Os resultados mostraram que não houve diferença estatística ( =0,05) entre os desgastes de esmalte causados por porcelanas glazeadas ou polidas. Verificou-se correlação média da rugosidade superficial e do módulo de elasticidade das porcelanas dentais com a capacidade de desgastar o esmalte dental, e correlação fraca entre a dureza e o desgaste. A análise qualitativa da rugosidade antes e após o desgaste mostrou diferenças entre as superfícies das porcelanas, embora não houvesse diferença estatística entre as médias de Ra inicial e final. Os resultados sugerem que o acabamento superficial adequado depende do tipo de porcelana utilizado


Subject(s)
Dental Enamel , Dental Porcelain , Dental Prosthesis , Radiometry
SELECTION OF CITATIONS
SEARCH DETAIL