Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Braz. dent. sci ; 26(1): 1-15, 2023. ilus
Article in English | LILACS, BBO | ID: biblio-1411456

ABSTRACT

The rehabilitation of patients with dental implant-supported restorations is an ideal treatment option in contemporary dentistry. The aim of this review was to compile and to demonstrate the mechanical response during loading condition, on the stress distributions of implant-supported prostheses. The findings show that the majority of stresses were concentrated in the cervical region of the implant/abutment interface and that they can be affected by several clinical parameters and loading conditions. Finally, the final prosthetic design should combine superior mechanical response, long-term survival rate and allow patient satisfaction. (AU)


A reabilitação de pacientes com restaurações implanto-suportadas é uma opção de tratamento ideal na odontologia contemporânea. O objetivo desta revisão foi compilar e demonstrar a resposta mecânica durante a aplicação de carga, na distribuição de tensão de próteses implanto-suportadas. Os achados mostram que a maioria das tensões se concentram na região cervical da interface implante/pilar e pode ser afetada por diversos parâmetros clínicos e condições de carregamento. Por fim, o desenho protético final deve combinar uma melhor resposta mecânica, taxa de sobrevida a longo prazo e permitir a satisfação do paciente. (AU)


Subject(s)
Prostheses and Implants , Dental Implants , Finite Element Analysis , Biomechanical Phenomena , Review
2.
São José dos Campos; s.n; 2020. 80 p. il., graf, tab..
Thesis in Portuguese, French | LILACS, BBO | ID: biblio-1224543

ABSTRACT

Este estudo avaliou a eficiência da pré-carga antes e após fadiga, desajuste vertical, carga para fratura e a concentração de tensões em restaurações de zircônia cimentadas ou acopladas a uma base de titânio (TB). Para isto, quarenta implantes foram incluídos em cilindros de polióxido de metileno (POM-DelrinDupont) e separados em dois grupos: restauração de zircônia cimentada em um TB ou acoplada em um TB experimental. Os corpos de prova tiveram o torque e o desajuste vertical avaliados antes e após a fadiga cíclica (200 N / 2 Hz / 2 x 106 ciclos / 37 °C). A carga até a fratura foi calculada em uma máquina universal de ensaios (1 mm / min, 1000 kgf) e as falhas foram avaliadas por estereomicroscopia e microscopia eletrônica de varredura. Modelos tridimensionais foram criados baseados na geometria dos espécimes laboratoriais e a concentração de tensão calculada pelo método dos elementos finitos. Os dados dos testes in vitro foram submetidos à análise de variância dois fatores e teste de Tukey (α = 0,5). As restaurações cimentadas apresentaram menor perda de torque (19,79 N.cm), menor desajuste vertical (3,77 µm), menor concentração de tensão na restauração (88,2 MPa) e maior carga de fratura (451,3 N) do que as restaurações acopladas (15,95 N.cm, 10,51 µm, 99,8 MPa e 390,8 N, respectivamente). Conclusão: A presença de uma camada de cimento entre a restauração e a base de titânio reduziu a suscetibilidade ao afrouxamento do parafuso do pilar, melhorou a resistência à carga compressiva e reduziu a concentração de tensão na restauração(AU)


The goal of this study was to evaluate the torque and vertical misfit before and after fatigue, the load to failure and the stress concentration of zirconia restorations cemented or notched to a titanium base (TB). Forty implants were included in Acetal Polyoxymethylene (POM-Delrin-Dupont) cylinders and divided in two groups: zirconia restoration cemented on a TB and zirconia restoration notched on an experimental TB. The specimens had their torque loosening and vertical misfit evaluated before and after cyclic fatigue (200 N / 2 Hz/ 2 x 106 cycles /37 °C). Load to failure was calculated in an universal testing machine (1 mm/min, 1000 kgf) and failures were evaluated by optical microscopy and scanning electron microscopy. Three-dimensional models were created based in the in vitro geometries and the stress concentration calculated using the finite element method. Data from the in vitro tests were submitted to two-way analysis of variance and Tukey test (α = 0.5). The cemented restorations presented less torque loosening (19.79 N.cm), lower vertical misfit (3.77 µm), lower stress concentration in the restoration (88.2 MPa) and higher fracture load (451.3 N) than notched restorations (15.95 N.cm, 10.51 µm, 99.8 MPa and 390.8 N, respectively). Conclusion: The presence of a cement layer between restoration and titanium base reduced the susceptibility to abutment screw loosening, improved the resistance to compressive load and reduced the stress concentration in the restoration(AU)


Subject(s)
Dental Implants , Dental Restoration Repair/adverse effects
3.
Rev. Assoc. Paul. Cir. Dent ; 52(3): 206-11, maio-jun. 1998. ilus
Article in Portuguese | LILACS, BBO | ID: lil-222792

ABSTRACT

Säo apresentadas as etapas clínicas e laboratoriais da utilizaçäo das porcelanas hidrotérmicas de baixa fusäo (LFC) na construçäo dos restaurados cerâmicos com uma maior qualidade estética


Subject(s)
Ceramics/analysis , Dental Restoration, Permanent , Dental Porcelain/analysis , Dentin-Bonding Agents/analysis , Dental Materials , Esthetics, Dental
SELECTION OF CITATIONS
SEARCH DETAIL