Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
ABC., imagem cardiovasc ; 29(4): 132-135, out.-dez. 2016. tab, graf
Article in Portuguese | LILACS | ID: biblio-834208

ABSTRACT

Fundamento: O ecocardiograma é particularmente importante para a avaliação de pacientes instáveis hemodinamicamente. Apesar de sua realização à beira do leito eliminar o risco resultante do transporte, a obtenção de imagens pode ficar prejudicada; o posicionamento adequado poderia contribuir para uma melhor qualidade de imagem e consequentemente análise do exame. Objetivo: Avaliar se o posicionamento do paciente pela enfermagem poderia influenciar a qualidade das imagens ecocardiográficas obtidas no leito. Métodos: Foram estudados de maneira consecutiva os pacientes com solicitação de exame no leito. Durante a realização de ecocardiograma transtorácico foram adquiridos vídeos dos planos para esternal longitudinal (PEL) e apical 4-câmaras(Apical-4C) e a imagem estática do fluxo aórtico (FAo) em decúbito lateral esquerdo (DLE) e em decúbito dorsal (DD). As imagens digitalizadas foram analisadas cegamente por dois observadores em relação ao tipo de decúbito utilizado. A qualidade das imagens foi graduada como 1:boa/ótima; 2:inadequada/ruim; e comparadas com o teste de Kappa e correlação de Pearson. Resultados: Foram estudados 68 pacientes, com idade de 69 ± 24 anos, sendo 37 do sexo masculino e superfície corpórea 1,85 ± 0,09 m2. Em relação aos cortes, as imagens em DLE apresentam melhor qualidade (p < 0,001) quando comparadas ao DD tanto para os vídeos Apical-4C (Kappa 0,19) e PEL (Kappa 0,25) e FAo (Kappa 0,13); a concordância entre os avaliadores para a qualidade das imagens foi de 95%. Conclusão: O posicionamento adequado do paciente no leito em decúbito lateral esquerdo contribui significativamente para a aquisição de imagens de melhor qualidade.


Background: Echocardiography is particularly important for assessing hemodynamically unstable patients. Despite being carried out at the bedside to eliminate the risk resulting from patient’s transportation, the imaging maybe impaired. Proper patient’s positioning could contribute to enhancing both the image quality and analysis of the exam. Objective: To evaluate whether patient’s positioning by nurses could influence the quality of the echocardiographic images obtained at the bedside. Methods: Patients whose examinations were requested to be carried out at the bedside were studied in a consecutive manner. During transthoracic echocardiography, videos of the parasternal longitudinal view (PLV) and 4-chamber apical view (Apical-4C) were obtained, as well as the still image of the aortic flow (FAo), in the left lateral decubitus (LLD) and supine decubitus (SD). The scanned images were blindly analyzed by two observers comparing the type of decubitus used. The image quality was rated as 1: good/excellent quality; 2: inadequate/poor, and then submitted to Kappa agreement test and Pearson correlation. Results: 68 patients were studied, aged 69 ± 24 years, 37 males and body surface 1.85 ± 0.09 m2. When the distinct views were compared, LLD images showed better quality (p < 0.001) when compared to SD for both the Apical-4C videos (Kappa 0.19) and PLV (Kappa 0.25) and FAo (Kappa 0.13); interobserver agreement of the quality of the images was 95%. Conclusion: Patient’s proper positioning in bed in left lateral decubitus contributes significantly to the acquisition of better quality images.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Diagnostic Imaging/methods , Echocardiography/methods , Patients , Patient Positioning/adverse effects , Critical Care/standards , Nursing Care/methods , Beds/trends , Data Interpretation, Statistical
2.
Einstein (Säo Paulo) ; 8(1)jan.-mar. 2010. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-542631

ABSTRACT

Objective: The prognosis of patients with acute myocardial infarction depends on multiple features that can demonstrate myocardial injury degree (such as serum markers of cardiac necrosis), and also on adaptive mechanisms relative to the acute event. The aim of the study was to assess the relation between biochemical and echocardiographic findings from three-dimensional echocardiographic (3D Echo) analysis and echocardiographic two-dimensional (2D Echo) left ventricular ejection fraction in patients with ST-segment elevation acute myocardial infarction , submitted to primary percutaneous treatment. Methods: A prospective study with 2D Echo and 3D Echo of 23 patients (17 males, mean age of 57 ± 13 years) with ST-segment elevation acute myocardial infarction, primarily percutaneously treated (stent). Serum cardiac markers (creatine kinase MB, Troponin I and Myoglobin) and serum brain natriuretic peptide were compared to echocardiographic parameters (volumes, left ventricular ejection fraction and ventricular dyssynchrony index). The statistical analysis was performed using Pearson?s correlation coefficient, 95% CI, p < 0.05, linear regression equation and Bland & Altman test. Results: Pearsons correlation coefficient (r)relative to 3D left ventricular ejection fraction: 1- brain natriuretic peptide: r: - 0.7427, p < 0.0001; 2- creatine kinase MB: r: - 0.660, p = 0.001. Left ventricular ejection fraction 2D (r) : 1- brain natriuretic peptide: r: - 0.5478, p = 0.001; 2- creatine kinase MB: r: - 0.4800, p < 0.0277. Other associations were not significant. Conclusions: In this series, it was observed better correlation in regard to serum creatine kinase MB , brain natriuretic peptide and 3D Echo left ventricular ejection fraction, when compared to 2D Echo left ventricular ejection fraction.


Objetivo: O prognóstico dos pacientes portadores de infarto agudo do miocárdico depende de múltiplos aspectos que espelhem o grau de agressão ao miocárdio (como marcadores enzimáticos de necrose miocárdica), assim como dos mecanismos de adaptação ao evento agudo. O objetivo do estudo foi verificar a associação entre os achados bioquímicos e ecocardiográficos derivados da análise ecocardiográfica transtorácica tridimensional (ECO 3D) com a fração de ejeção do ventrículo esquerdo (ECO 2D) em pacientes acometidos por infarto agudo do miocárdio com supradesnivelamento do segmento ST, que tenham sido submetidos a tratamento primário percutâneo. Métodos: Estudo prospectivo com Eco 3D e 2D de 23 indivíduos (17 homens, 57 ± 13 anos), acometidos por infarto agudo do miocárdio com elevação do segmento ST, primariamente tratados com implante de stent coronariano. Foi feita a dosagem sérica de creatina cinase fração MB, Troponina I, Mioglobina e peptídeo atrial natriurético e comparada com os parâmetros ecocardiográficos (volumes, fração de ejeção do ventrículo esquerdo e índice de dissincronia ventricular). A análise estatística foi feita com a determinação do coeficiente de correlação (Pearson), IC = 95%, p < 0,05, com teste de regressão linear e teste de Bland & Altman. Resultados: Coeficiente de correlação (r) entre fração de ejeção do ventrículo esquerdo 3D: 1- peptídeo atrial natriurético: r: - 0,7427, p < 0,0001; 2- creatina cinase fração MB: r: -0,660, p = 0,001. fração de ejeção do ventrículo esquerdo 2D (r) : 1- peptídeo atrial natriurético: r: - 0,5478, p = 0,001; 2- creatina cinase fração MB: r: -0,4800, p < 0,0277. As demais associações entre os parâmetros ecocardiográficos e as dosagens séricas não foram significativas. Conclusões: Nesta série, foi observada correlação melhor entre a dosagem sérica de peptídeo atrial natriurético, de creatina cinase fração MB e a fração de ejeção do ventrículo esquerdo aferida por Eco 3D do que a correlação com a fração de ejeção do ventrículo esquerdo aferida por Eco 2D.

SELECTION OF CITATIONS
SEARCH DETAIL