Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Main subject
Year range
1.
Repert. med. cir ; 33(2): 178-185, 2024. tab, graf
Article in Spanish | LILACS, COLNAL | ID: biblio-1561074

ABSTRACT

Introducción: el reto de líquidos es una prueba que consiste en administrarlos y medir la respuesta hemodinámica mediante el cambio del gasto cardíaco (GC), aunque solo medir el GC resulta insuficiente. El acople ventrículo-arterial (AVA) (elastancia arterial efectiva/ elastancia telesistólica: Eae/Ets) aparece como una variable que evalúa el estado cardiocirculatorio en forma integral. Objetivo: evaluar el AVA en un biomodelo de choque endotóxico y durante retos de líquidos. Materiales y métodos: biomodelo de choque endotóxico (9 porcinos). Se midieron variables hemodinámicas cada hora desde un tiempo 0 (T0) hasta T6. Se realizaron 5 retos de líquidos entre T0 y T4. El tiempo de hipotensión se denominó TH0. Se calcularon diferencias de medianas de variables entre T0-T4. Se clasificaron los retos en dos grupos según el delta del AVA (AVA posreto-AVA prerreto), en ΔAVA≤0 o >0, se midieron variables antes y después de cada reto. Se determinó la relación lactato/piruvato (L/P) en T0, T3 y T6, se establecieron correlaciones entre la diferencia LP T6-T0 y de variables hemodinámicas. Resultados: el AVA aumentó (1.58 a 2,02, p=0.042) por incremento en la Eae (1.74 a 2,55; p=0.017). El grupo ΔAVA≤0 elevó el GC (4.32 a 5,46, p=0.032) y el poder cardíaco (PC) (0.61 a 0,77, p=0,028). El Δ L/P se correlacionó con el Δ del índice de choque sistólico y diastólico (r=0.73), pero no con el del AVA. Conclusión: durante el choque endotóxico el AVA aumentó de manera significativa. Durante el reto de líquidos el grupo Δ AVA≤0, elevó el GC y PC. El Δ L/P no se correlacionó con variables del AVA.


Introduction: fluid challenges (FCs) consist of measuring hemodynamic response through changes in cardiac output (CO) after fluid administration, although only measuring CO proves insufficient. Ventriculo-arterial coupling (V-A) (effective arterial elastance / tele-systolic elastance: E(a)/Ets) are variables used for a comprehensive cardiac and circulatory status appraisal. Objective: to evaluate V-A in an endotoxic shock bio-model by FCs. Materials and methods: an endotoxic shock bio-model (9 pigs). Hemodynamic variables were measured every hour from time 0 (T0) to T6. Five FCs were performed between T0 and T4. Hypotension time was referred to as HT. The median differences in variables between T0-T4 were calculated. Challenges were classified into two groups according to V-A delta (post-challenge V-A - pre-challenge V-A). In ΔV-A≤0 o>0, variables were measured before and after each FC. The lactate to pyruvate (L/P) ratio was determined at T0, T3 and T6. Correlations between the LP T6-T0 difference and hemodynamic variables, were established. Results: V-A increased (1.58 to 2,02, p=0.042) as Eae increased (1.74 to 2.55; p=0.017). CO (4.32 to 5.46, p=0.032) and cardiac power (CP) (0.61 to 0.77, p=0,028) increased, in the ΔV-AC≤0 group. The ΔLP correlated with the systolic and diastolic shock index (r=0.73), but not with V-A. Conclusion: V-A increased significantly during endotoxic shock. The ΔAVA≤0 group, showed elevated CO and CP during FC. ΔLP did not correlate with any of the V-A variables.


Subject(s)
Humans , Sepsis , Endotoxemia
2.
Rev. colomb. anestesiol ; 43(3): 214-218, July-Sept. 2015.
Article in English | LILACS, COLNAL | ID: lil-757257

ABSTRACT

Introduction: The passive leg raising test (PLR) allows physicians to determine which patients require treatment with intravenous fluids. Objectives: It is important to be aware of tools that help us to determine the response to the passive leg raising test, as well as understanding in which clinical situations it can be performed. Materials and methods: Non-systematic review. Medline and PubMed databases were consulted in search of relevant articles. Results: Through echocardiography, pulse pressure and capnography can be determined as a response to leg raising. Conclusions: This article explores the tools that are useful in determining the response to this maneuver, and the clinical conditions in which it is indicated.


Introducción: la prueba de elevación de piernas pasivas permite determinar en qué paciente se requiere manejo con líquidos endovenosos. Objetivos: es importante conocer las herramientas que ayudan a determinar la respuesta a la prueba de elevación de piernas pasiva, además conocer en qué situaciones clínicas se puede realizar. Materiales y métodos: revisión no sistemática. Se consultaron las siguientes bases de datos Medline y Pubmed, en búsqueda de artículos relevantes. Resultados: mediante ecocardiografía, presión de pulso y capnografía se puede determinar la respuesta a la elevación de piernas. Conclusiones: el presente artículo explora las herramientas que son útiles para determinar la respuesta a esta maniobra y las condiciones clínicas donde se indica.


Subject(s)
Humans
SELECTION OF CITATIONS
SEARCH DETAIL