1.
Chinese Journal of Medical Imaging Technology ; (12): 462-467, 2017.
Article in Chinese | WPRIM | ID: wpr-608744

ABSTRACT

Objective To explore the feasibility of axial whole-liver one-stop examination with Revolution CT.Methods Totally 19 patients were underwent upper-abdominal enhanced examination with Revolution CT and acquired whole-liver CT perfusion (CTP),vein phase and balanced phase enhanced images.Two observers recorded the rank and peak CT value corresponding to time-density curve (TDC) of abdominal aorta and portal vein respectively on the CTP images.The perfusion parameters including blood flow (BF),blood volume (BV),hepatic arterial fraction (HAF),mean transit time (MTT),time to peak (TP) of left and right liver lobe were measured.The images of hepatic artery CTA and portal vein CTV were reconstructed and the arterial phase enhanced images were extracted using the images corresponding to abdominal aorta and portal vein peak TDC.And the radiation dose of CT perfusion and one-stop examination were recorded.The differences between perfusion parameters of left and right liver lobe were compared and the consistency of two observers were analyzed.Results The differences between BV and MTT of left and right liver lobe were statistical significance (both P<0.05).The subjective scores of hepatic artery CTA,portal vein CTV and arterial phase images were greater than 1 point.The two observers were in great consistence (Kappa>0.6).The effective radiation dose in perfusion phase and one-stop examination were 14.47 mSv and 21.29 mSv.Conclusion With low radiation dose,Revolution CT axial wholeliver perfusion one-stop examination can provide multiple quantitative parameters of liver CTP and clear hepatic artery CTA,portal vein CTV and 3 phase enhanced scan images,which has broadly prospective in clinical application.

2.
Chinese Journal of Radiology ; (12): 279-283, 2017.
Article in Chinese | WPRIM | ID: wpr-515268

ABSTRACT

Objective To assess the value of spectral CT imaging in distinguishing mass type colorectal adenocarcinoma from colorectal adenoma. Methods Forty patients underwent preoperative abdominal dual energy spectral CT scan were analyzed restrospectively, including 17 with colorectal adenomas and 23 with mass type colorectal adenocarcinomas proven by endoscopic and surgical pathology. All patients underwent plain and three-phase enhanced CT scanning. The conventional polychromatic CT value and its pre- and postcontrast CT values, monochromatic CT value of 40 to 100 keV, the slope of spectral curve and iodine(water) concentration were measured, and the maximum diameter of the lesion was recorded. The maximum diameters of the lesions and imaging parameter differences between the adenomas and adenocarcinomas in plain and three-phase enhanced scan were analyzed with independent sample t tests. The data of the parameters with significant differences were further analyzed by ROC curves. Results The maximum diameters of the adenomas and mass type adenocarcinomas were (1.97 ± 0.54), (2.32±0.53) cm respectively, and there was no statistically significant difference (t=-2.011, P=0.051). There was no statistically differences of the conventional polychromatic CT value and its pre-and postcontrast CT values between the two groups in 4 phases (P>0.05). However, in the arterial phase, the CT values of adenomas were significantly lower than those of adenocarcinomas at low (40, 50 keV) energy (P0.05). The slope of spectral curve and the iodine(water) concentration both showed significant differences in the arterial phase between the two groups (P0.05).The largest area under the ROC curve of the iodine(water) concentration in the arterial phase was 0.757 in differentiating adenomas and mass type adenocarcinomas, with sensitivity of 73.9%and specificity of 82.4%at the cut-off of 21.02 mg/cm3. Conclusion Spectral CT imaging is valuable in differentiating colorectal adenoma from mass type colorectal adenocarcinoma with the parameters of the arterial phase.

3.
Chinese Journal of Rehabilitation Theory and Practice ; (12): 1430-1433, 2016.
Article in Chinese | WPRIM | ID: wpr-506719

ABSTRACT

Objective To evaluate whether visual exploration therapy could lead to the recovery of cognitive function and activities of daily living (ADL) of stroke patients with unilateral neglect. Methods From January, 2012 to June, 2014, 24 stroke patients with unilateral neglect were randomly divided into control group (n=12) and observaton group (n=12). The control group received conventional rehabilita-tion therapy, and the observation group received visual exploration therapy additionally. They were evaluated with Mini-Mental State Exami-nation (MMSE), Montreal Cognitive Assessment (MoCA), modified Barthel index (MBI) and Chinese Behavioral Inattention Test-Hong Kong version (CBIT-HK). Results All the scores improved after treatment in both groups (t>5.375, P2.120, P0.05). Conclusion Visual exploration therapy could not only fa-cilitate the recovery of unilateral neglect in stroke patients, but also improve their cognitive function and activities of daily living.

4.
Journal of Practical Radiology ; (12): 1237-1241, 2016.
Article in Chinese | WPRIM | ID: wpr-495960

ABSTRACT

Objective To assess the utility of single source-dual energy CT for distinguishing bladder cancer from hematoma. Methods We retrospectively identified 14 patients with postoperative or follow-up bladder hematoma who had undergone dual energy protocol (40-140 keV)scanning by single source-dual energy CT.The subjective scoring of tumor detection and image quality,the optimal monochrome images and iodine-water images were evaluated by two radiologists who didn’t know the results.The consistency of two observers was analyzed by Kappa test.Mann-Whitney U test was used to compare the difference between the two kinds of diseases and ROC curve was used to analyze the diagnostic efficiency.The statistical differences of image quality scoring among different images were obtained by using Mann-Whitney U test.Results The consistency of the two observers about scoring of lesion detection was good for all groups.There were statistical differences between two groups in non-enhanced phase and arterial phase of mixed-energy images,non-enhanced phase,arterial phase and delayed phase of optimal monochromatic images,and all phase of iodine-water images. The AUC of iodine-water images in the four phases (0.985,1.000,0.955,0.924,respectively)were all higher than that of polychrome unenhanced and arterial phase images (0.909,0.909).The diagnostic efficiency of arterial phase on iodine-water images was the highest.Sensitivity and specificity were both 100% when score was greater than 2.5.There was no statistical difference between two kinds of diseases on non-enhanced phase,delayed phases of mixed-energy or monochromatic images(P >0.05).There were no statistical differences in image quality scoring among the three groups with the same phases (P>0.05).Conclusion Optimal monochromatic images and iodine-water images of single source-dual energy CT are more effective than conventional CT in distinguishing bladder cancer from hematoma.

5.
Chinese Journal of Medical Imaging ; (12): 517-522, 2015.
Article in Chinese | WPRIM | ID: wpr-468458

ABSTRACT

PurposeTo investigate the effects of the low concentration contrast medium combined with optimal single source spectral imaging on displaying feeding arteries of gastrointestinal tract malignant tumors.Materials and Methods Seventy-one patients of body mass index (BMI) >25 kg/m2 with gastrointestinal tract malignant tumors were prospectively studied. All the cases were randomly divided into two groups: high concentration group (33 cases with high concentration contrast medium of 350 mgI/ml in routine scan) and low concentration group (38 cases with low concentration contrast medium of 270 mgI/ml in optimal single source spectral imaging). The optimal single source images were generated automatically. The subjective image scores, CT value of the tumor feeding arteries, image noise, contrast-to-noise ratio (CNR) and CT dose index of volume (CTDIvol) of optimal single source spectral images in two groups were compared. Results The optimal single source of low concentration group were 51-60 keV. The subjective image score of low concentration group was higher than high concentration group (Z=-4.280,P0.05).Conclusion The low concentration contrast medium with optimal single source spectral imaging in patients with large BMI may improve CTA image quality of feeding arteries of gastrointestinal tract malignant tumors without increasing radiation dose.

6.
Chinese Journal of Digestive Surgery ; (12): 741-745, 2015.
Article in Chinese | WPRIM | ID: wpr-480197

ABSTRACT

Objective To explore the application value of optimal energy imaging technique of monoenergetic dual-energy computed tomography (DECT) in feeding arteries examination of rectal cancer.Methods The clinical data of 33 patients with rectal cancer who were admitted to the First Affiliated Hospital of Dalian Medical University from July 2012 to July 2014 were analyzed retrospectively.The polychromatic and monochromatic images of feeding arteries of tumors were reconstructed and evaluated using a subjective image quality score of 5-point scale by 2 observers.The consistency and scores of evaluation were analyzed by the κ test and MannWhitney U test.The CT value of feeding arteries of tumors and hip muscle,image noise and contrast to noise ratio (CNR) were measured and calculated by 2 observers,and were compared by the independent sample t test.The consistency of data between the 2 observers were measured by the intra-class correlation coefficients (ICC).Results Inferior mesenteric arteries were contributor of blood supply of tumors in all the 33 patients,including 4 cases with right inferior rectal artery as contributor of blood supply of tumors,2 cases with bilateral inferior rectal artery.Among patients with abnormal blood vessels,there were 8 patients with left colic artery and sigmoid artery having common trunk,4 patients with left colic artery originated from Inferior mesenteric artery,1 patient with absence of left colic artery.The 0-,1-,2-,3-,4-score polychromatic image quality of feeding arteries of tumors were detected in 0,13,13,5,2 patients and 0,11,14,6,2 patients by 2 observers,respectively.The 0-,1-,2-,3-,4-score monochromatic image quality of feeding arteries of tumors were detected in 0,0,7,7,19 patients and 0,0,6,9,18 patients by 2 observers,respectively.Good interobserver agreement was found for the evaluation of subjective scores (κ =0.864,0.897).The subjective scores of image quality of feeding arteries in the polychromatic images and in the monochromatic images were 1.9 ± 0.9 and 3.4 ± 0.8,with significant difference (Z =-5.21,P < 0.05).The latter was superior to the former.The ICC values of the CT values of feeding arteries of tumor,hip muscle,image noise and CNR were 0.953,0.907,0.839,0.964 and 0.966,0.933,0.952,0.962 from the 2 observers,with a good consistency.The CT values of feeding arteries of tumor,gluteal muscles,image noise and CNR in the polychromatic images and in the monochromatic images were (234 ± 52)HU and (412±83)HU,(57±9)HU and (71 ±15)HU,(21 ±3)HU and (31 ±6)HU,9 ±3 and 11 ±4,respectively,with significant differences (t =-18.65,-4.44,-14.14,-6.55,P < 0.05).The levels of monochromatic images of 33 patients were 51-61 keV,with a median of 55 keV.Conclusion The optimal energy imaging technique of monoenergetic DECT can improve the angiographic quality of feeding arteries in patients with rectal cancer.

7.
Chinese Journal of Physical Medicine and Rehabilitation ; (12): 680-682, 2015.
Article in Chinese | WPRIM | ID: wpr-479983

ABSTRACT

Objective To evaluate the effects of cranial electrotherapy stimulation therapy combined with psychological intervention for treating depression after cerebral infarction.Methods Eighty persons diagnosed with depression after cerebral infarction were divided randomly into a treatment group and a control group.Both groups were given routine rehabilitation training and psychological intervention, but the treatment group also received microcurrent transcranial electrical stimulation treatment.All the patients were evaluated with Hamilton's depression scale (HAMD) and the mini-mental state exam (MMSE) and given Barthel index (BI) scores before and after 4 weeks of treatment.Results There was no significant difference between the 2 groups in terms of any of the measures before treatment.After 4 weeks of treatment, both groups had improved significantly, but the improvements on all measures were significantly better in the treatment group.Conclusion Cranial electrotherapy combined with psychological intervention can significantly improve symptoms of depression and cognitive function in patients with post-stroke depression, and play an important role in improving their daily life.

8.
Clinical Medicine of China ; (12): 1190-1191, 2014.
Article in Chinese | WPRIM | ID: wpr-475098

ABSTRACT

Objective To investigate the value of application of stent in the treatment of colorectal malignant obstruction.Methods A total of 28 cases with colorectal malignant obstruction were treated with stents in endoscopic joint X line temporarily or palliatively in the Yanhua Hospital of Beijing from May 2007 to June 2013.Intestinal obstruction ease conditions and complications were observed.Results Twenty-eight cases received with stent,and only 1 case failed.Twenty-one patients,who showed the relief of obstructive symptoms,were performed one-stage operation after 7 to 10 d.The patients recovered very well without stents shifting and intestinal perforation.Conclusion The stent treatment by endoscopic on colorectal malignant obstruction is a temporary or palliative treatment which can avoid the colostomy and improve the quality of life.It is a safe and reliable method which is worthy to be popularized.

9.
Chinese Journal of Physical Medicine and Rehabilitation ; (12): 816-818, 2008.
Article in Chinese | WPRIM | ID: wpr-381439

ABSTRACT

Objective To investigate changes of surface electromyogr8phic(sEM G)signal of pelvic floor muscles in complete spinal cord injury(cSCI)patients with neurogenic bowel dysfunction.Methods Fifteen hospitalized patients with cSCI(observation group)and fifteen normal subjects(control group)were involved in this study.The root mean square(RMS)of sEMG signals were collected at pelvic floor muscles with rectal surface electrode when subjects'pelvic floor muscles were rest(10 s),fleetly contract(2 s×3),continually contract(10 s).Both groups'data of different contracting states of pelvic floor muscles were analyzed and compared.Results The max RMS and average RMS(16.61±2.83,13.52±2.22)at pelvic floor muscles'rest in observation group were higher than that in control group(8.41±5.55,3.45±1.53).There was statistical difference between two groups(P<0.01).In the subjects of observation group max RMS and average RMS(20.24±13.99,13.36±2.39)at continual contraction and average RMS(13.40±2.31)at fleet contraction were nearly the same as RMS value at pelvic floor muscles'rest.There was no statistical difference between these two states(P>0.05).Conclusion The sEMG could be a quantitative index in assessing function of pelvic floor muscles and the neurogenic bowel dysfunction after cSCI.It can supply some clinical value in framing the training of pelvic floor muscles and improving the bowel dysfunction.