Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. j. phys. ther. (Impr.) ; 20(3): 223-230, tab, graf
Article in English | LILACS | ID: lil-787643

ABSTRACT

ABSTRACT Background The Glittre-ADL test (TGlittre) is a valid and reliable test for the evaluation of functional capacity and involves multiple physical activities of daily living (PADL), which are known to be troublesome to patients with Chronic Obstructive Pulmonary Disease (COPD). However, it is still unknown if this test is also able to reflect the functional performance of patients with COPD. Objective To investigate whether the TGlittre reflects the functional performance of COPD patients and whether the necessary time to complete the TGlittre and the PADL varies according to disease severity. Method Thirty-eight patients with COPD (age 65, SD=7 years; forced expiratory volume in the first second 41.3, SD=15.2% predicted) underwent anthropometric and lung function assessments and were submitted to the TGlittre and PADL measurement. Results TGlittre performance correlated significantly (p<0.05) with PADL variables, such as time sitting (r=0.50), walking (r=-0.46), number of steps taken (r=–0.53), walking movement intensity (r=–0.66), walking energy expenditure (r=-0.50), and total energy expenditure (r=–0.33). TGlittre performance was not significantly different in patients among the Global Initiative for COPD (GOLD) spirometric stages, but walking and sitting time were significantly lower and greater, respectively, in severe and very severe patients compared to those with moderate disease (p<0.05). Conclusion The performance on the TGlittre correlates with walking and sitting time and other real life PADL measurements. The severity of the disease is associated with the differences in the level of physical activity in daily life more than in functional capacity.


Subject(s)
Humans , Activities of Daily Living , Pulmonary Disease, Chronic Obstructive/physiopathology , Exercise Test , Walking
2.
Braz. j. phys. ther. (Impr.) ; 17(3): 227-235, jun. 2013. tab, graf
Article in English | LILACS | ID: lil-680657

ABSTRACT

BACKGROUND: the assessment of functional capacity in patients with chronic obstructive pulmonary disease (COPD) has been performed by simple and easy to apply methods that mimic everyday activities, such as the Chester step test (TChester). OBJECTIVES: to investigate whether TChester is able to differentiate functional capacity and the magnitude of cardiorespiratory response of patients with COPD from healthy subjects; and to compare it with the cardiorespiratory response induced by shuttle test (TShuttle) and six-minute walk test (6MWT). METHOD: 10 patients with COPD (64±10 years, and forced expiratory volume at the first second - FEV1 38.1±11.8% predicted) and 10 healthy subjects (63±7 years, and FEV1 of 95.8±18.0% predicted) underwent evaluation of pulmonary function, functional status and capacity (6MWT, TShuttle and TChester). RESULTS: COPD patients had worst performance in all tests, when compared to healthy subjects (TChester 2,1±0,9 vs. 4,1±1,1 completed levels; TC6min: 435±105,1 vs. 593±87,3 m; TShuttle 251±84,6 vs. 436±55,4 m; p<0.05). TChester correlated with TShuttle and 6MWT (r =0.67 and 0.83, respectively, p<0.05). There were no differences in heart rate and dyspnea in TChester levels between groups (p>0.05). SpO2 was lower in COPD patients since the first TChester level (p<0.05). CONCLUSION: TChester is valid in the assessment of functional capacity of COPD patients, being able to distinguish them from healthy subjects, inducing similar cardiovascular demand and greater desaturation in COPD patients. .


CONTEXTUALIZAÇÃO: A avaliação da capacidade funcional em pacientes com doença pulmonar obstrutiva crônica (DPOC) tem sido realizada por métodos simples, de fácil aplicação e que mimetizam as atividades cotidianas, como o teste step Chester (TChester). OBJETIVOS: Investigar se o TChester é capaz de diferenciar a capacidade funcional e a magnitude da resposta cardiorrespiratória de pacientes com DPOC e de indivíduos saudáveis e comparar com a resposta cardiorrespiratória induzida pelos testes de caminhada de seis minutos (TC6min) e Shuttle (TShuttle). MÉTODO: Participaram dez pacientes com DPOC (64±10 anos, volume expiratório forçado no primeiro segundo - VEF1 de 38,1±11,8% do predito) e dez saudáveis (63±7 anos, IMC de 24,5±3,1 e VEF1 de 95,8±18,0% do predito) que realizaram avaliação da função pulmonar, estado e capacidade funcional. RESULTADOS: O grupo DPOC obteve pior desempenho nos três testes, quando comparado ao controle (TChester 2,1±0,9 vs 4,1±1,1 níveis completos; TC6min: 435±105,1 vs 593±87,3 m; TShuttle 251±84,6 vs 436±55,4 m; p<0,05). O TChester correlacionou-se com o TShuttle e com o TC6min (r=0,67 e 0,83, respectivamente; p<0,05). Não se observaram diferenças na frequência cardíaca (FC) e dispneia nos níveis do TChester entre os grupos (p>0,05). A SpO2 apresentou-se mais reduzida no grupo DPOC já no primeiro nível do TChester (p<0,05). CONCLUSÃO: O TChester é válido na avaliação da capacidade funcional de pacientes com DPOC, sendo capaz de diferenciá-los de indivíduos saudáveis, induzindo similar demanda cardiovascular e maior dessaturação nos pacientes ...


Subject(s)
Female , Humans , Male , Middle Aged , Exercise Tolerance , Exercise Test/methods , Heart/physiopathology , Pulmonary Disease, Chronic Obstructive/physiopathology , Respiration
SELECTION OF CITATIONS
SEARCH DETAIL