Arq. bras. cardiol ; 120(6): e20220594, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1439363

ABSTRACT

Resumo Fundamento O padrão-ouro atual dos stents farmacológicos (SF) coronários consiste em ligas metálicas com hastes mais finas e polímeros bioabsorvíveis. Objetivos Nosso objetivo foi comparar um stent eluidor de sirolimus de hastes ultrafinas (Inspiron®) com outras plataformas de SF de terceira geração em pacientes com infarto do miocárdio com supradesnivelamento do segmento ST (IAMCSST) submetidos à intervenção coronária percutânea (ICP) primária. Métodos Analisamos dados de um registro multicêntrico de IAMCSST de centros de referência da Região Sul do Brasil. Todos os pacientes foram submetidos à ICP primária, seja com Inspiron® ou outro SF de segunda ou terceira geração. Foi calculado pareamento por escore de propensão (PEP) para gerar grupos semelhantes (Inspiron® versus outros stents) em relação às características clínicas e do procedimento. Todos os testes de hipótese tiveram um nível de significância bilateral de 0,05. Resultados De janeiro de 2017 a janeiro de 2021, 1.711 pacientes foram submetidos à ICP primária, e 1.417 pacientes preencheram nossos critérios de inclusão (709 pacientes no grupo Inspiron® e 708 pacientes no grupo dos outros SF de segunda ou terceira geração). Após PEP, a amostra do estudo foi composta por 706 pacientes (353 pacientes no grupo Inspiron® e 353 pacientes no grupo dos demais SF de segunda ou terceira geração). As taxas de revascularização do vaso alvo (odds ratio [OR] 0,52; intervalo de confiança [IC] 0,21 a 1,34; p = 0,173), trombose de stent (OR 1,00; IC 0,29 a 3,48;p = 1,000), mortalidade (hazard ratio 0,724; IC 0,41 a 1,27; p = 0,257) e os desfechos cardiovasculares maiores (OR 1,170; IC 0,77 a 1,77; p = 0,526) foram semelhantes entre os grupos após um acompanhamento mediano de 17 meses. Conclusão Nossos achados mostram que o stent Inspiron® foi eficaz e seguro quando comparado a outros SF de segunda ou terceira geração em uma coorte contemporânea do mundo real de pacientes com IAMCSST submetidos à ICP primária.


Abstract Background The current gold standard of coronary drug-eluting stents (DES) consists of metal alloys with thinner struts and bioresorbable polymers. Objectives Our aim was to compare an ultrathin strut, sirolimus-eluting stent (Inspiron®) with other third-generation DES platforms in patients with ST-elevation myocardial infarction (STEMI) submitted to primary percutaneous coronary intervention (PCI). Methods We analyzed data from a STEMI multicenter registry from reference centers in the South Region of Brazil. All patients were submitted to primary PCI, either with Inspiron® or other second- or third-generation DES. Propensity score matching (PSM) was computed to generate similar groups (Inspiron® versus other stents) in relation to clinical and procedural characteristics. All hypothesis tests had a two-sided significance level of 0.05. Results From January 2017 to January 2021, 1711 patients underwent primary PCI, and 1417 patients met our entry criteria (709 patients in the Inspiron® group and 708 patients in the other second- or third-generation DES group). After PSM, the study sample was comprised of 706 patients (353 patients in the Inspiron® group and 353 patients in the other the other second- or third-generation DES group). The rates of target vessel revascularization (OR 0.52, CI 0.21 - 1.34, p = 0.173), stent thrombosis (OR 1.00, CI 0.29 - 3.48, p = 1.000), mortality (HR 0.724, CI 0.41 - 1.27, p = 0.257), and major cardiovascular outcomes (OR 1.170, CI 0.77 - 1.77, p = 0.526) were similar between groups after a median follow-up of 17 months. Conclusion Our findings show that Inspiron® was effective and safe when compared to other second- or third-generation DES in a contemporary cohort of real-world STEMI patients submitted to primary PCI.

2.
J. bras. nefrol ; 39(1): 91-94, Jan.-Mar. 2017. graf
Article in English | LILACS | ID: biblio-841197

ABSTRACT

Abstract Introduction: Patients with chronic kidney disease (CKD) are at increased risk for thrombotic complications. The use of central venous catheters as dialysis vascular access additionally increases this risk. We describe the first case of Budd-Chiari syndrome (BCS) secondary to central venous catheter misplacement in a patient with CKD. Case report: A 30-year-old female patient with HIV/AIDS and CKD on hemodialysis was admitted to the emergency room for complaints of fever, prostration, and headache in the last six days. She had a tunneled dialysis catheter placed at the left jugular vein. The diagnosis of BCS was established by abdominal computed tomography that showed a partial thrombus within the inferior vena cava which extended from the right atrium to medium hepatic vein, and continuing along the left hepatic vein. Patient was treated with anticoagulants and discharged asymptomatic. Discussion: Budd-Chiari syndrome is a rare medical condition caused by hepatic veins thrombosis. It can involve one, two, or all three of the major hepatic veins. It is usually related to myeloproliferative disorders, malignancy and hypercoagulable states. This case calls attention for inadvertent catheter tip placement into hepatic vein leading to this rare complication. Conclusion: Assessment of catheter dialysis tip location with radiological image seems to be a prudent measure after each procedure even if the tunneled dialysis catheter has been introduced with fluoroscopy image.


Resumo Introdução: Pacientes com doença renal crônica (DRC) apresentam risco aumentado de complicações trombóticas e o uso de cateter venoso central para realização de hemodiálise aumenta este risco. Nós descrevemos um caso de síndrome de Budd-Chiari (SBC) causado pelo mal posicionamento de um cateter de diálise em um paciente com DRC e, para nosso conhecimento, este é o primeiro caso relatado na literatura. Caso clínico: Paciente feminina, 30 anos, com diagnóstico de HIV/SIDA e DRC em hemodiálise foi admitida na emergência com queixas de febre, prostração e cefaleia há 6 dias. Ela apresentava um cateter de diálise tunelizado implantado 7 dias antes na veia jugular esquerda. O diagnóstico de SBC foi realizado por tomografia computadorizada abdominal que mostrava um trombo no interior da veia cava inferior o qual estendia-se desde o átrio direito até a veia hepática esquerda. O cateter foi removido e a paciente foi anticoagulada. A paciente estava assintomática no momento da alta hospitalar. Discussão: SBC é uma condição clínica rara causada por trombose das veias hepáticas, podendo envolver desde uma até todas as três principais veias. Esta síndrome é em geral associada a desordens mieloproliferativas, a malignidades e a situações de hipercoagulabilidade. Este caso demonstra que o mal posicionamento da ponta do cateter no interior da veia hepática causou esta rara complicação. Conclusão: Realização de exame radiológico para avaliar localização da ponta do cateter de diálise é uma medida prudente após cada procedimento, mesmo nos casos de implante de cateter de diálise tunelizados com fluoroscopia.