Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Fisioter. mov ; 27(4): 565-572, Oct-Dec/2014. tab
Article in English | LILACS | ID: lil-732492

ABSTRACT

Introduction Knees osteoarthritis (OA) is a complex degenerative disease with intra-articular changes affecting the amplitude of the quadriceps angle (Q). To measure this variable, it is necessary to use reliable protocols aiming at methodological reproducibility. The objective was to evaluate the intra-examiner and inter-examiner reliability of clinical and radiographic measures of the Q angle and to investigate the relationship between the degree of OA and the magnitude of this angle in the elderly. Materials and methods 23 volunteers had the Q angle measured by two evaluators at 48-h interval. Clinical measurements were collected by using the universal goniometer in the same position adopted in the radiographic examination. Results The intra-examiner reliability was good (0.722 to 0.763) for radiographic measurements and low (0.518 to 0.574) for clinical assessment, while inter-examiner reliability was moderate (0.634) for radiographic measurements and low (0.499) to the clinics. The correlation analysis between the radiographic values with the OA classification showed no correlation between them (p = 0.824 and r = -0.024). Conclusion Clinically, it is suggested that the radiographic examination is preferable to evaluate the Q angle of elderly women with knee osteoarthritis. Moreover, the magnitude of this angle did not correlate with the degree of impairment of OA in this population.


Introdução A osteoartrite (OA) de joelhos é uma doença degenerativa complexa com alterações intra-articulares que comprometem a amplitude do ângulo do quadríceps (Q). Para mensuração dessa variável, é necessária a utilização de protocolos que apresentem confiabilidade, visando reprodutibilidade metodológica. Objetivo Avaliar a confiabilidade intra e interexaminadores das medidas clínicas e radiográficas do ângulo Q e verificar se existe relação entre o grau de OA e a magnitude deste ângulo em idosas. Materiais e métodos 23 voluntárias, tiveram o ângulo Q mensurado por 2 avaliadores, com intervalo de 48 horas. As medidas clínicas foram coletadas por meio do goniômetro universal na mesma posição adotada no exame radiográfico. Resultados A confiabilidade intraexaminador foi boa (0,722–0,763) nas medidas radiográficas e baixa (0,518–0,574) nas medidas clínicas, enquanto a confiabilidade interexaminadores foi moderada (0,634) nas medidas radiográficas e baixa (0,499) nas clínicas. A análise da correlação entre os valores radiográficos com a classificação da OA não demonstrou correlação entre os mesmos (p = 0,824 e r = -0,024). Conclusão Clinicamente, sugere-se que o exame radiográfico seja preferível para avaliação do ângulo Q de idosas com OA de joelhos. Além disto, a magnitude deste ângulo não se relacionou com o grau de acometimento da OA nesta população.

2.
Acta fisiátrica ; 18(1): 16-20, mar. 2011.
Article in Portuguese | LILACS | ID: lil-663371

ABSTRACT

O limiar de lactato (LL) é utilizado como um marcador da acidose metabólica e representa o momento durante o exercício em que o lactato sanguíneo começa aumentar de forma exponencial. Este LL tem sido utilizado como medidor de condicionamento físico, indicador sensível do estado do treinamento aeróbico em sujeitos saudáveis e doentes, além disso, auxilia na identificação do estímulo de treinamento ideal e na prescrição da intensidade de treinamento. O objetivo do presente estudo foi avaliar a confiabilidade intra e interexaminadores das medidas do LL obtidas através do método de detecção visual. Para isso, 31 voluntárias do sexo feminino (67,50 ± 4,41 anos; 1,52 ± 0,07 m; 64,55 ± 11,46 kg), aparentemente saudáveis e no período pós-menopausa, participaram do estudo. O LL foi determinado a partir de um teste realizado na esteira ergométrica até a fadiga, que consistiu de estágios com carga progressiva (variação da velocidade e/ou inclinação). Amostras de sangue foram coletadas por meio de uma punção na polpa digital do dedo médio a cada 3 minutos durante o teste. Em seguida, foram construídos os gráficos do método de detecção visual (software Prisma5) a partir da concentração de lactato sanguíneo coletado a cada estágio do exercício (intervalo de 3 minutos) em função da taxa de trabalho correspondente ao consumo de oxigênio (VO2) estimado durante o teste na esteira. A análise estatística foi realizada através do Coeficiente de Correlação Intraclasse (CCI). A confiabilidade intraexaminador foi excelente (0,950 - 0,952) e a confiabilidade interexaminadores foi boa (0,789 - 0,770). Dessa forma,sugere-se que o método de detecção visual é uma forma segura e confiável para detectar o LL na prática clínica e em pesquisas.


The lactate threshold (LT) is used as a marker for metabolic acidosis and represents the time during the exercise in which blood lactate begins to increase exponentially. LT has been used as a measurer of physical capacity,a sensitive indicator of the state of aerobic training in healthy and sickpatients, in addition, assists in identifying the optimal training stimulus and the prescription of training intensity. The aim of this study was to evaluate the reliability, intra and interrater, of the LT obtained by a visual detection method. For this, 31 female volunteers (67.50 ± 4.41 years, 1.52± 0.07 m, 64.55 ± 11.46 kg), apparently healthy and postmenopausal, participated in the study. The LT was determined from a test performed on a treadmill, which consisted of stages with progressive workload(variation of speed and/or incline), until the patient experienced fatigue. Blood samples were collected from a finger prick of the middle finger every 3 minutes during the test. Next, the visual detection method graphics were constructed (software Prisma5) from the blood lactate concentration collected at each stage of exercise (3 minute intervals) depending on the work rate corresponding to oxygen consumption (VO2) estimated during the treadmill test. Statistical analysis was performed by the intraclass correlation coefficient (ICC). Intrarater reliability was excellent (0.950- 0.952) and interrater reliability was good (0.789 - 0.770). Thus, it has been determined that the visual detection method is a safe and reliable way to detect the LT in clinical practice and research.


Subject(s)
Humans , Female , Exercise/physiology , Anaerobic Threshold/physiology , Reproducibility of Results , Exercise Test , Vision, Ocular , Lactic Acid/blood , Data Interpretation, Statistical
3.
Rev. Ter. Man ; 7(31): 168-172, maio-jun. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-537999

ABSTRACT

A articulação talocrural é essencial para o desenvolvimento da marcha, adaptando-se aos diversos tipos de superfícies, estando diretamente relacionada com o equilíbrio e estabilidade. Técnicas de manipulação osteopática têm sido usadas para tratar distúrbios e restaurar a mecânica articular, e podem influenciar diretamente o sistema de controle postural. O objetivo do estudo foi analisar as alterações na estabilidade unipodal de tornozelo geradas por meio da aplicação de uma técnica de thrust. Participaram deste estudo 20 homens com idade 22±2 anos, divididos em dois grupos: G1 (n=10) grupo que recebeu a técnica manipulativa e G2 (n=10) controle. A técnica utilizada foi a manipulação talocrural no membro inferior dominante. Os valores estabilométricos foram obtidos pela plataforma Cibex Reactor antes e cinco minutos após a aplicação da técnica em G1. Os voluntários de G2 foram submetidos ao mesmo protocolo de avaliação, porém sem receber a técnica thrust. Foram obtidos os seguintes resultados: Em G1, observou-se diferenças estatisticamente signifi cantes após a manipulação talocrural (p<0,05), antes os voluntários apresentaram valores estabilométricos de 8.169 pontos. Após a intervenção experimental houve uma queda de 14,35% (6.996 pontos), indicando que houve uma alteração na estabilidade quando comparado ao grupo controle, o qual não obteve diferenças nos resultados. Assim, sugere-se que a manipulação pode ser eficaz na melhora do equilíbrio e estabilidade unipodal de tornozelo.


The talocrural joint is essential for the gait development. It adapts itself to the various areas and types of terrain where you walk and is directly related to balance and stability. Manipulative techniques were used to treat disorders and restore the joint movements, and may influence the postural control system. The study’s goal was to evaluate the immediate changes in stability generated by the application of thrust technique. Twenty men, 22±2 years old, were separated into two groups: G1 (n=10) manipulated group, and G2 (n=10) control group. The technique used was the talocrural thrust in the dominant leg. The data was collected by the stabilometric platform Cibex Reactor before and five minutes after the application of the technique in G1. The group G2 performed only the stabilometric test at the same time, without receiving the thrust. The values obtained were statistically signifi cant for G1 after the manipulation (P<0,05), the stabilometric values before the technique was 8.169 points, and after was a decline of 14.35% (6,996 points), indicating that there was a change in the stability when compared to the control group, which there were no differences between the results. The results of this study suggest that the manipulation can be effective in improving balance and stability.


Subject(s)
Humans , Male , Adult , Tarsal Joints , Osteopathic Medicine , Ankle
SELECTION OF CITATIONS
SEARCH DETAIL