Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Ann Card Anaesth ; 2022 Jun; 25(2): 164-170
Article | IMSEAR | ID: sea-219199

ABSTRACT

Background:Pulmonary regurgitation is imminent after transannular patch (TAP). We analyze the long?term performance of untreated autologous pericardium (UAP) as valve substitute at pulmonary position in patients requiring TAP. Material and Methods: This cross?sectional study include patients operated between 2007 and 2012 (n = 92). A sample of 19 patients was selected for this study which had a follow?up of more than 3 years. This includes patients with no TAP (n = 4) and with TAP and valve substitute, a monocusp (n = 11) or a tricuspid valve (n = 4) at neopulmonary annulus. Patients underwent echocardiography for assessment of right ventricle function and 18 fluoro?deoxyglucose PET CT scan for measurements of valve substitute at neopulmonary annulus. The target to blood ratio (TBR) of uptake of glucose by monocusp was measured at the cooptation edge of the neopulmonary valve. Results: The median age of the patients is 14 (9 – 37). RV function is preserved (TAPSE 18.9 (10.6 – 22.8)) at a mean follow?up of 4 years (3?9). The measurements of monocusp shows a shrinkage in height of the cusp by 35.5% (70% – 1.0%) and length by 7% (?44% ? +104%). There was less shrinkage observed in patients below 15 years of age. The TBR of monocusp was 0.945 (0.17 – 3.35) with a strong correlation between the TBR values of aortic valve leaflet and monocusp leaflet of same patient. Conclusion: The UAP is functional and successful as a valve substitute at neo pulmonary annulus at long?term follow?up. It has resisted calcification and has shown uptake of glucose in physiological limits.

2.
Ann Card Anaesth ; 2019 Jul; 22(3): 273-277
Article | IMSEAR | ID: sea-185846

ABSTRACT

Introduction: Tetralogy of Fallot requiring transannular repair of the right ventricular outflow tract (RVOT) are exposed to free pulmonary insufficiency and hence inevitable right ventricular dysfunction. This study analyzes the function and structure of untreated autologous pericardium monocusp used to create a competent pulmonary valve. Materials and Methods: This is a retrospective analysis of 52 cases operated between December 2006 and December 2012. Untreated autologous pericardium was used for creating a competent pulmonary valve following a transannular patch. They are followed for functional and structural assessment of the pulmonary valve by echocardiography. Positron emission tomography (PET) with 18 fluorodeoxyglucose was performed in two cases for profiling the pulmonary valve. Results: Median age was 10.5 years (1–38). The follow-up was complete for 42 (80.76%) patients for 3 years and 25 (48.07%) patients for 5 years. The RVOT gradient was 42 mmHg (16–96) in the year of surgery, which reduced to 26 mmHg (10–58) and pulmonary insufficiency that was present in 8.3% of patients in 1st year was witnessed in 22.7% in the 5th year of follow-up. The monocusp patch was successful in creating a competent valve while maintaining its structure at 3 years; however, it became distorted and retracted at 5 years of follow-up. There was no calcification in any of the patients. PET-computed tomography confirmed the uptake of glucose by monocusp at 1 year of follow-up. Conclusion: The untreated autologous pericardium functioned well when it was used to create a competent pulmonary valve at short term and midterm. Although it changed in its structure; there was no calcification at 5 years of follow-up.

SELECTION OF CITATIONS
SEARCH DETAIL