Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Article in Spanish | LILACS, BINACIS | ID: biblio-1353998

ABSTRACT

En 2021, se cumplen 40 años de la publicación original que describió al implante "intracondilar con capacidad rotatoria Endo-Model", evolución del diseño precedente St. George, ahora capaz de proveer doble grado de libertad de movimiento y reducir la tensión en la interfase cemento-hueso. Condición singular es que dicha publicación no es referida en estudios bibliométricos, a pesar de lo cual su indicación electiva está aún vigente tras cuatro décadas. Un trabajo merece la calificación de "clásico" no exclusivamente por el volumen de citaciones, sino fundamentalmente por la confianza que inspira la aplicación de su contenido en el largo plazo. Contemporáneamente, todas las compañías de la industria de implantes que lideran el mercado internacional han incorporado en sus catálogos un modelo propio de implante a bisagra rotacional. La magnitud de constricción comparativa es un dilema y, por ende, materia de discusión. Contemporáneamente aplicando la tecnología de sensores inerciales se ha logrado resolver la cuestión: la bisagra rotacional ofrece menor constricción que el implante de constricción condilar. Nivel de Evidencia: V


The year 2021 marks the 40th anniversary of the original publication describing the "Endo-model intracondylar rotational" implant, the evolution of the previous St Georg design, now providing two-degree-of-freedom motion and reducing stress on the cement-bone interface. A unique condition is that the publication is not reported in bibliometric studies, although its elective indication still exists after four decades. A work deserves the qualification of "classic" not only for the volume of citations but fundamentally for the confidence that the application of its content inspires in the long term. Currently all the leading international companies in the implant industry have included in their catalogs their own rotating hinge implants. The scale of comparative constriction is a dilemma and thus a topic for discussion. Currently, the matter has been solved applying inertial sensors technology: the rotating hinge provides less constriction than the condylar constriction implant. Level of Evidence: V


Subject(s)
Orthopedics/history , Knee Prosthesis/history , Knee Prosthesis/trends
2.
Rev. Asoc. Argent. Ortop. Traumatol ; 86(5) (Nro Esp - AACM Asociación Argentina de Cirugía de la Mano): 711-711, 2021.
Article in Spanish | LILACS, BINACIS | ID: biblio-1353978
4.
5.
Rev. Asoc. Argent. Ortop. Traumatol ; 82(4): 342-343, dic. 2017.
Article in Spanish | LILACS | ID: biblio-908037
6.
Rev. Asoc. Argent. Ortop. Traumatol ; 82(4): 321-326, dic. 2017. []
Article in Spanish | LILACS, BINACIS | ID: biblio-896276

ABSTRACT

Introducción: Los efectos de las ondas de choque extracorpóreas se han investigado en osteoblastos humanos, focos fracturarios, seudoartrosis y células periósticas. Los mejores resultados del tratamiento de la seudoartrosis con ondas de choque extracorpóreas se han documentado para seudoartrosis hipertróficas. El objetivo de este estudio fue investigar el efecto de la terapia con ondas de choque extracorpóreas sobre un foco de seudoartrosis "atrófica" generado en tibia de conejo. Métodos: Se establecieron tres grupos: A, fracturados sometidos a ondas de choque extracorpóreas; B ("control"), fracturados no sometidos a ondas de choque y C, no fracturados (pierna derecha). Se trataron 37 conejos (cuniculus NV) blancos y esqueléticamente maduros de Nueva Zelanda. Se practicó la cauterización del periostio con electrobisturí bipolar en una extensión de 20 mm, en ambos muñones óseos (proximal y distal). Luego se aplicaron ondas de choque extracorpóreas en una sola sesión. Se realizaron tinciones con hematoxilina-eosina. Se efectuó el análisis biomecánico con un método de carga a "3 puntos". Se estudiaron la carga máxima aplicada y el módulo de elasticidad para cada grupo. Resultados: El estudio histológico permitió registrar signos de consolidación -callo fracturario perióstico y endostal- considerablemente mayores en las tibias de los animales del grupo A (tratado con ondas de choque extracorpóreas) que en las del grupo B "control". Conclusión: En un modelo experimental original de seudoartrosis atrófica generada por electrocauterización en tibia de conejos, se registraron cambios significativos radiográficos e histológicos luego de la intervención del foco mediante ondas de choque extracorpóreas. Nivel de Evidencia: II


Introduction: The effects of extracorporeal shock wave therapy (ESWT) have been investigated in human osteoblasts, fracture foci, nonunion and periosteum cells. The best results of nonunion treatment with ESWT have been documented for hypertrophic type. The objective of this study was to investigate the effects of ESWT in an atrophic nonunion focus generated in a rabbit tibia model. Methods: Three groups were included: A, fractures receiving ESWT; B ("control"), fractures not receiving ESWT, and C, no fractures (right leg). A total of 37 New Zealand white and skeletally mature rabbits (cuniculus NV) were treated. Periosteum was cauterized using bipolar electrocautery at 20 mm in both bone stumps (proximal and distal). Then ESWT was applied in one session. Staining with hematoxylin-eosin was used. A biomechanical analysis with a 3-point loading system was performed. Maximum load and elastic modulus were evaluated in each group. Results: Histological study evidenced signs of union (periosteal and endosteal fracture callus) which were considerably larger in tibias of Group A (treated with ESWT) as compared to the control group (Group B). Conclusion: In an experimental model of atrophic pseudarthrosis caused by electrocautery in tibias of rabbits, significant radiographic and histological changes were observed after focus intervention with the application of ESWT. Level of Evidence: II


Subject(s)
Animals , Pseudarthrosis/therapy , Tibial Fractures/physiopathology , High-Energy Shock Waves/therapeutic use , Disease Models, Animal , Rabbits
7.
Rev. Asoc. Argent. Ortop. Traumatol ; 81(3): 190-198, set. 2016. ilus, graf, tab
Article in Spanish | LILACS, BINACIS | ID: biblio-842491

ABSTRACT

Introducción: Se han logrado excelentes resultados con los tallos pulidos, cementados con tecnicas modernas, aun en pacientes jovenes, aunque su combinacion con superficie ceramica solo se ha comunicado en forma aislada. El objetivo de este estudio es analizar los resultados y las complicaciones de una serie de artroplastias de cadera con superficie ceramicaceramica, y tallos pulidos y conicos cementados con tecnicas de segunda y tercera generacion. Materiales y Métodos: Se evaluaron los resultados, las complicaciones relacionadas con el par de friccion y la supervivencia de 277 pacientes tratados con artroplastias de cadera con tallos pulidos y conicos cementados, en forma moderna, asociados a un par de friccion ceramica-ceramica. La edad promedio fue 56 anos; y el seguimiento minimo, de 6 anos. Resultados: No se detectaron aflojamientos radiologicos, migraciones, ni radiolucencias. La incidencia de infeccion fue del 1,3%. La incidencia de complicaciones por causas atribuibles a la cupla ceramica fue del 4%, y la de revision, del 1,4%. La supervivencia a siete anos, considerando revision por cualquier motivo fue del 95,8% (IC95% 94-99%), y considerando el aflojamiento aseptico, del 100%. Todos los casos de luxacion produjeron impregnacion metalica de la cabeza ceramica y esta fue la causa mas frecuente de revision. La incidencia de sonidos ha sido excepcionalmente baja comparada con las de otras series con fijacion no cementada. Conclusión: La asociacion de cementado moderno y tallos pulidos y conicos con superficies ceramicas ha demostrado ser una alternativa atractiva con una supervivencia a siete anos del 95%, sin aflojamientos asepticos. Nivel de Evidencia: IV


Introduction: Polished cemented stems with modern cementing techniques have shown excellent results even in young patients; nevertheless their results in combination with ceramic bearings are not known due to the lack of reports. We analyzed the results and complications of hip hybrid arthroplasties combining second- and third-generation cemented polished tapered stems and ceramic-ceramic bearings. Methods: Results, complications related to ceramic surfaces and survival rate of 277 patients treated with hip arthroplasties with polished stems cemented with modern techniques were evaluated. The mean age was 56 years and the minimum follow-up was 6 years. Results: No radiographic loosening, migration or radiolucencies were detected. The infection rate was 1.3%. The complication rate due to ceramic bearing was 4%, revision was required in 1.4%. Seven-year survival with revision for any reason as the endpoint was 95.8% (95%CI, 94-99%) whereas it reached 100% for aseptic loosening. Dislocation with metal impregnation was responsible of almost all revisions caused from complications related to bearing surfaces. The incidence of squeaking has been exceptionally low compared to other series with cementless fixation. Conclusion: The combination of modern cementing techniques of polished stems with ceramic on ceramic bearings has proven to be an attractive alternative with a 7-year survival of 95%, and no aseptic loosening. Level of Evidence: IV


Subject(s)
Adult , Middle Aged , Postoperative Complications , Cementation/methods , Arthroplasty, Replacement, Hip/adverse effects , Hip Joint/surgery , Follow-Up Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL