Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. j. pharm. sci ; 51(3): 663-671, July-Sept. 2015. tab, graf
Article in English | LILACS | ID: lil-766313

ABSTRACT

The purpose of present study was aimed at developing self emulsifying drug delivery system in liquid and then in pellet form that would result in improved solubility, dissolution and permeability of the poorly water soluble drug carvedilol. Pellets were prepared using extrusion-spheronization technique incorporating liquid SEDDS (carvedilol, capmul MCM EP, cremophore EL, tween 20, propylene glycol), adsorbents ( and crospovidone), microcrystalline cellulose and binder (povidone K-30). Ternary phase diagram was constructed to identify different oil-surfactant-cosurfactant mixtures according to the proportion of each point in it. The optimal CAR-SEDDS pellets showed a quicker redispersion with a droplet size of the reconstituted microemulsion being 160.47 nm, which was almost unchanged after solidification. SEM analysis confirmed good spherical appearance of solid pellets; DSC and XRD analysis confirmed that there was no crystalline carvedilol in the pellets. Pellets were then capable of transferring lipophilic compounds into the aqueous phase and significantly enhancing its release with respect to pure drug.


O propósito do presente estudo foi desenvolver um sistema líquido de liberação de fármacos auto emulsificante e, então, na forma de pélete, que poderia resultar em aprimoramento da solubilidade, da dissolução e permeabilidade do fármaco carvedilol, pouco solúvel em água. Os péletes foram preparados utilizando-se a técnica de extrusão-esferonização, incorporando líquido SEDDS (carvedilol, capmul MCM EP, Cremofor EL, Tween 20, propileno glicol), adsorventes (e crospovidona), celulose microcristallina e ligante (povidona K-30). O diagrama de fase ternário foi construído para identificar as misturas diferentes de óleo-tensoativo-co-tensoativo, de acordo com a proporção em cada ponto delas. Os péletes CAR-SEDDS mostraram redispersão mais rápida, com tamanho de gota da microemulsão reconstituída de 160,47 nm, que se mostrou quase inalterada após a solidificação. A análise por SEM confirmou a aparência esférica dos péletes sólidos. Análise por DSC e XRD confirmou que não havia carvedilol cristalino nos péletes. Estes foram, então capazes de transferir os compostos lipofílicos para a fase aquosa, aumentando, significativamente, sua liberação em relação ao fármaco puro.


Subject(s)
Chemistry, Pharmaceutical , Drug Implants , Emulsifying Agents , Emulsifying Agents/analysis
2.
Braz. j. pharm. sci ; 51(3): 653-661, July-Sept. 2015. tab, graf
Article in English | LILACS | ID: lil-766319

ABSTRACT

The present work describes development and validation of a specific, sensitive, precise and stability-indicating high-performance liquid chromatographic method of analysis of atorvastatin calcium and celecoxib, both as a bulk drug and in niosomal formulation. The analysis has been performed by using Cosmosil-C18 column (4.6 mm´250 mm, 5 m) at 25 °C using acetonitrile: ammonium acetate buffer pH 5.0: methanol (50:25:25 v/v/v) as mobile phase. The detection was carried out at 277nm with a flow rate of 1.0mL/min. The retention times of Atorvastatin calcium and Celecoxib were 6.195 and 3.989min, respectively. The method was validated according to ICH guidelines, for specificity, precision, linearity, accuracy and robustness. Atorvastatin calcium and Celecoxib were subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. The degradation was observed in oxidation and acid hydrolysis. The linearity for atorvastatin calcium and celecoxib were in the range of 100-500 µg/mL. The recovery study of atorvastatin and celecoxib were found to be in the range of 98.96 - 99.92% and 98.90-100%, respectively. The proposed method was validated and successfully applied to the estimation of Atorvastatin calcium and Celecoxib in combined in-house niosomal formulation.


O presente trabalho descreve o desenvolvimento e a validação de método de análise por cromatografia de alta eficiência específico, sensível, preciso e indicador de estabilidade de atorvastatina cálcica e celecoxibe, ambos como fármaco e como formulação niosômica. A análise foi realizada utilizando coluna Cosmosil-C18 (4,6 mm´250 mm, 5 m) a 25 °C, e acetonitrila: tampão acetato de amônio pH 5,0: metanol (50:25:25 v/v/v) como fase móvel. A detecção foi realizada a 277 nm, com fluxo de 1,0 mL/min. Os tempos de retenção de atorvastatina cálcica e de celecoxibe foram 6,195 e 3,989 min, respectivamente. O método foi validado de acordo com as regras da ICH para especificidade, precisão, exatidão e robustez. A atorvastatina cálcica e o celecoxibe foram submetidos a condições de estresse por hidrólise, oxidação, fotólise e degradação térmica. A degradação foi observada por oxidação e hidrólise ácida. Observou-se a linearidade da atorvastatina cálcica e do celecoxibe na faixa de 100-500 µg/mL. A recuperação da atorvastatina e do celecoxibe foi observada na faixa de 98,96-99,92% e 98,90-100%, respectivamente. O método proposto foi validado e aplicado com sucesso para a determinação de atorvastatina cálcica e celecoxibe em formulação niosômica caseira combinada.


Subject(s)
Validation Study , Chromatography, Reverse-Phase , Celecoxib/analysis , Atorvastatin/analysis , Chemistry, Pharmaceutical/methods , Chromatography, Liquid
SELECTION OF CITATIONS
SEARCH DETAIL