Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Braz. dent. sci ; 19(4): 32-41, 2016. ilus, tab
Article in English | LILACS, BBO | ID: biblio-850485

ABSTRACT

Objetivo: O objetivo deste estudo foi avaliar a adesão (RU) de sistemas autocondicionantes à dentina afetada por cárie (CAD) e dentina normal (ND), após diferentes técnicas de remoção de tecido cariado. Materiais e Métodos: Foram utilizados vinte e quatro molares humanos extraídos, com lesão de cárie oclusal. A amostra foi aleatoriamente dividida em 5 grupos, de acordo com o método de remoção do tecido cariado: G1 - controle negativo (sem remoção); G2 - disco abrasivo; G3 – broca de aço de baixa velocidade; G4 - laser Nd:YAG (21,2 J/cm2 ); G5 - laser Er:YAG (80,24 J/cm2 ). Dentinas normais e afetados / infectados foram tratadas com o sistema adesivo (Clearfil SE Bond) e coroas de resina foram construídas. Resultados: ANOVA um fator mostrou diferença estatisticamente significante entre os grupos experimentais (p < 0,001), com um valor menor para a dentina infectada (G1), quando comparado com todos os grupos experimentais. Maior RU foi observada para ND irradiada com laser Er:YAG, quando comparado a CAD. Para os espécimes tratados com broca e laser Nd:YAG, a RU em ND e CAD foi semelhante. Conclusão: a dentina infectada não é um substrato adequado para a adesão; laser de Nd:YAG e brocas de aço mostraram-se adequados como ferramenta de tratamento das dentinas normal e afetada prévio à instalação de restaurações adesivas. Contudo, ambas as dentinas tratadas pelos laser de Er:YAG, não interagiram adequadamente com o sistema auto-condicionante resultando em fraca adesão


Objective: The aim of this study was to evaluate the adhesion of a self-etching system to cariesaffected dentin (CAD) and sound dentin (SD) after different caries removal techniques by using microtensile bond strength test (μTBS). Materials and Methods: Twenty-four extracted human molars with coronal carious lesions were used. The samples were randomly divided into 5 groups, according to caries removal method: G1 - negative control (no removal); G2 abrasive disc; G3 – slow speed steel bur; G4 - Nd:YAG laser (energy density 21.2 J/cm2 ); G5 - Er:YAG laser (energy density 80.24J/cm2 ). SD and CAD/ infected dentin substrates were tested. Self-etch system (Clearfil SE Bond) was applied and resin crowns were built up. Results: One-way ANOVA showed statistically significant difference between experimental groups (p < 0.001), with significantly lower results for infected dentin (G1), when compared to all other experimental groups. A statistically significant higher bond strength value was observed for SD irradiated with Er:YAG laser when compared to CAD. For bur and Nd:YAG laser specimens, SD and CAD showed the same bonding performance. Conclusion: infected dentin is not an adequate substrate for bonding; Nd:YAG laser and steel burs showed the same bonding performance for both SD and CAD; while both dentins, when irradiated by Er:YAG laser, did not adequately interact with self-etching system resulting in poor adhesion


Subject(s)
Dentin , Lasers, Solid-State
2.
São Paulo; s.n; 2015. 105 p. ilus, tab. (BR).
Thesis in Portuguese | LILACS, BBO | ID: biblio-871116

ABSTRACT

Este estudo longitudinal investigou a influência de tratamentos de superfície com o laser de Er:YAG com 50?s de largura de pulso sobre a adesão de dois sistemas adesivos autocondicionantes (SA) em dentina hígida (DH) e dentina afetada por cárie (DAC) através dos teste de resistência de união (RU) de microcisalhamento (?SBS), teste de ultramicrodureza da camada de adesivo (NdA) e da camada híbrida (NdCH), além de análise da interface adesiva com microscopia eletrônica de varredura (MEV). A análise qualitativa dos tratamentos de superfície realizados foi executada através de MEV e microscopia eletrônica de transmissão (MET). A dentina oclusal planificada de 215 molares humanos foi protegida com verniz ácido resistente, exceto em janela de 4x5mm para produção de DAC artificial após 7 dias de desafio cariogênico com biofilme de S. mutans, permitindo dados pareados por substrato. Os espécimes foram divididos nos grupos experimentais de acordo com: tratamento de superfície [controle-sem tratamento-(G1); Laser 80-80mJ, 2 Hz, 12.58J/cm2-(G2); Laser 50-50mJ, 10 Hz, 9.4J/cm2-(G3)]; sistema adesivo [Clearfil SE Bond(CF) e Single Bond Universal(SB)]; substrato [DH(h) ou DAC(a)] e tempo de armazenamento em saliva artificial [24 horas (24) ou 1 ano (1)], compondo 24 grupos experimentais: CFG1h24; CFG1h1; CFG1a24; CFG1a1; CFG2h24; CFG2h1; CFG2a24; CFG2a1; CFG3h24; CFG3h1; CFG3a24; CFG3a1; SBG1h24; SBG1h1; SBG1a24; SBG1a1; SBG2h24; SBG2h1; SBG2a24; SBG2a1; SBG3h24; SBG3h1; SBG3a24; SBG3a1. Nos grupos tratados com laser a largura temporal de pulso foi ajustada em 50?s. A resina composta Z350XT foi utilizada para a confecção dos corpos de prova. Os sistemas adesivos foram aplicados de acordo com as instruções do fabricante. As análises de MEV e MET de superfície avaliaram somente o efeito dos tratamentos em ambos os substratos testados. Os valores de RU e de nanodureza foram analisados através do teste de ANOVA (três fatores) e do teste de comparações múltiplas de Tukey (?=0,05). Para o teste de ?SBS, para ambos os SA, e todos tratamentos de superfície, a DAC apresentou valores de RU menores comparados à DH; a influência do armazenamento em saliva artificial foi substrato dependente: corpos de prova obtidos com DAC apresentaram queda nos valores de RU após 1 ano de armazenamento, enquanto nenhuma diferença entre os grupos experimentais foi observada em dentina hígida. NdA revelou que apenas os corpos de prova construídos com CF apresentaram redução dos valores após 1 ano. A NdCH obtida com CF e SB, resultou em menores valores em DAC comparada à DH, após 1 ano de armazenamento ambos os substratos apresentaram redução da NdCH, para todos tratamentos de superfície. A MEV revelou que todas as interfaces adesivas, especialmente aquelas obtidas em DAC, sofreram degradação intensa após 1 ano. Os tratamentos com Laser 80 e Laser 50 promovem alteração superficial característica de ablação em DAC e DH, conforme observado em MEV de superfície, e alterações de fibrilas colágenas observadas em MET. Independentemente dos SA, a adesão e nanodureza em DAC é menor que em DH. Todas as interfaces adesivas obtidas foram sensíveis ao armazenamento em saliva artificial por 1 ano. A adesão não foi influenciada pelo tratamento com o laser Er:YAG com 50?s de largura de pulso.


This longitudinal study investigated the influence of super short pulse Er:YAG laser treatment on microshear bond strength (?SBS), adhesive and hybrid layer nanohardness test and qualitative interface scanning electron microscopy (SEM) of two self-etch adhesive systems to sound (SD) and caries-affected like dentin (CAD). Additionally, qualitative investigation of surface treatments by SEM and transmission electron microscopy (TEM) were performed. CAD lesions (4x5mm) were produced by 7 days S. mutans biofilm cariogenic challenge in 215 human ground flat human dentin specimens, enabling paired data by substrate. Specimen were divided in groups according to surface treatment [control-no treatment-(G1); Laser 80-80mJ, 2Hz, 12.58J/cm2-(G2); Laser 50-50mJ, 10Hz, 9.4J/cm2-(G3)]; self-etching adhesive system [Clearfil SE Bond(CF) and Single Bond Universal(SB)]; substrate [SD(h) or CAD(a)] and artificial saliva storage [24 hours(24) or 1 year(1)]: CFG1h24; CFG1h1; CFG1a24; CFG1a1; CFG2h24; CFG2h1; CFG2a24; CFG2a1; CFG3h24; CFG3h1; CFG3a24; CFG3a1; SBG1h24; SBG1h1; SBG1a24; SBG1a1; SBG2h24; SBG2h1; SBG2a24; SBG2a1; SBG3h24; SBG3h1; SBG3a24; SBG3a1. Pulse duration was set in 50?s for laser groups. ?SBS, nanohardness and interface SEM specimen preparation was constructed with Z350XT composite resin. Adhesive systems were applied according to manufacturer's instructions. Surface SEM and TEM specimen only evaluated treatment effects on distinct substrates. The ?SBS and nanohardness means were analysed using three-way ANOVA and Tukey´s multiples comparisons test (?=0.05). For ?SBS test, for both adhesive systems, and all surface treatments, CAD revealed lower ?SBS values compared to SD; the influence of artificial saliva storage was substrate dependent. CAD specimens resulted in lower ?SBS values after 1 year, while no difference among experimental groups was observed in SD. The adhesive layer (AL) nanohardness statistical evaluation revealed that only CF specimens decreased the AL nanohardness after 1 year of storage. The hybrid layer (HL) produced with CF and SB, resulted in lower nanohardness values for CAD than SD, which reduces after 1 year storage, for all surface treatments. Interface SEM analysis revealed that all adhesive interfaces, especially those in CAD, have experienced degradation after 1 year of storage. Laser 80 and Laser 50 promotes surface ablation characteristics in...


Subject(s)
Humans , Male , Female , Dentin/physiology , Microscopy, Electron, Scanning/methods , Microscopy, Electron, Scanning
3.
São Paulo; s.n; 2015. 105 p. ilus, tab. (BR).
Thesis in Portuguese | LILACS, BBO | ID: biblio-867719

ABSTRACT

Este estudo longitudinal investigou a influência de tratamentos de superfície com o laser de Er:YAG com 50?s de largura de pulso sobre a adesão de dois sistemas adesivos autocondicionantes (SA) em dentina hígida (DH) e dentina afetada por cárie (DAC) através dos teste de resistência de união (RU) de microcisalhamento (?SBS), teste de ultramicrodureza da camada de adesivo (NdA) e da camada híbrida (NdCH), além de análise da interface adesiva com microscopia eletrônica de varredura (MEV). A análise qualitativa dos tratamentos de superfície realizados foi executada através de MEV e microscopia eletrônica de transmissão (MET). A dentina oclusal planificada de 215 molares humanos foi protegida com verniz ácido resistente, exceto em janela de 4x5mm para produção de DAC artificial após 7 dias de desafio cariogênico com biofilme de S. mutans, permitindo dados pareados por substrato. Os espécimes foram divididos nos grupos experimentais de acordo com: tratamento de superfície [controle-sem tratamento-(G1); Laser 80-80mJ, 2 Hz, 12.58J/cm2-(G2); Laser 50-50mJ, 10 Hz, 9.4J/cm2-(G3)]; sistema adesivo [Clearfil SE Bond(CF) e Single Bond Universal(SB)]; substrato [DH(h) ou DAC(a)] e tempo de armazenamento em saliva artificial [24 horas (24) ou 1 ano (1)], compondo 24 grupos experimentais: CFG1h24; CFG1h1; CFG1a24; CFG1a1; CFG2h24; CFG2h1; CFG2a24; CFG2a1; CFG3h24; CFG3h1; CFG3a24; CFG3a1; SBG1h24; SBG1h1; SBG1a24; SBG1a1; SBG2h24; SBG2h1; SBG2a24; SBG2a1; SBG3h24; SBG3h1; SBG3a24; SBG3a1.


Nos grupos tratados com laser a largura temporal de pulso foi ajustada em 50?s. A resina composta Z350XT foi utilizada para a confecção dos corpos de prova. Os sistemas adesivos foram aplicados de acordo com as instruções do fabricante. As análises de MEV e MET de superfície avaliaram somente o efeito dos tratamentos em ambos os substratos testados. Os valores de RU e de nanodureza foram analisados através do teste de ANOVA (três fatores) e do teste de comparações múltiplas de Tukey (?=0,05). Para o teste de ?SBS, para ambos os SA, e todos tratamentos de superfície, a DAC apresentou valores de RU menores comparados à DH; a influência do armazenamento em saliva artificial foi substrato dependente: corpos de prova obtidos com DAC apresentaram queda nos valores de RU após 1 ano de armazenamento, enquanto nenhuma diferença entre os grupos experimentais foi observada em dentina hígida. NdA revelou que apenas os corpos de prova construídos com CF apresentaram redução dos valores após 1 ano. A NdCH obtida com CF e SB, resultou em menores valores em DAC comparada à DH, após 1 ano de armazenamento ambos os substratos apresentaram redução da NdCH, para todos tratamentos de superfície. A MEV revelou que todas as interfaces adesivas, especialmente aquelas obtidas em DAC, sofreram degradação intensa após 1 ano. Os tratamentos com Laser 80 e Laser 50 promovem alteração superficial característica de ablação em DAC e DH, conforme observado em MEV de superfície, e alterações de fibrilas colágenas observadas em MET. Independentemente dos SA, a adesão e nanodureza em DAC é menor que em DH. Todas as interfaces adesivas obtidas foram sensíveis ao armazenamento em saliva artificial por 1 ano. A adesão não foi influenciada pelo tratamento com o laser Er:YAG com 50?s de largura de pulso.


This longitudinal study investigated the influence of super short pulse Er:YAG laser treatment on microshear bond strength (?SBS), adhesive and hybrid layer nanohardness test and qualitative interface scanning electron microscopy (SEM) of two self-etch adhesive systems to sound (SD) and caries-affected like dentin (CAD). Additionally, qualitative investigation of surface treatments by SEM and transmission electron microscopy (TEM) were performed. CAD lesions (4x5mm) were produced by 7 days S. mutans biofilm cariogenic challenge in 215 human ground flat human dentin specimens, enabling paired data by substrate. Specimen were divided in groups according to surface treatment [control-no treatment-(G1); Laser 80-80mJ, 2Hz, 12.58J/cm2-(G2); Laser 50-50mJ, 10Hz, 9.4J/cm2-(G3)]; self-etching adhesive system [Clearfil SE Bond(CF) and Single Bond Universal(SB)]; substrate [SD(h) or CAD(a)] and artificial saliva storage [24 hours(24) or 1 year(1)]: CFG1h24; CFG1h1; CFG1a24; CFG1a1; CFG2h24; CFG2h1; CFG2a24; CFG2a1; CFG3h24; CFG3h1; CFG3a24; CFG3a1; SBG1h24; SBG1h1; SBG1a24; SBG1a1; SBG2h24; SBG2h1; SBG2a24; SBG2a1; SBG3h24; SBG3h1; SBG3a24; SBG3a1. Pulse duration was set in 50?s for laser groups. ?SBS, nanohardness and interface SEM specimen preparation was constructed with Z350XT composite resin. Adhesive systems were applied according to manufacturer's instructions.


Surface SEM and TEM specimen only evaluated treatment effects on distinct substrates. The ?SBS and nanohardness means were analysed using three-way ANOVA and Tukey´s multiples comparisons test (?=0.05). For ?SBS test, for both adhesive systems, and all surface treatments, CAD revealed lower ?SBS values compared to SD; the influence of artificial saliva storage was substrate dependent. CAD specimens resulted in lower ?SBS values after 1 year, while no difference among experimental groups was observed in SD. The adhesive layer (AL) nanohardness statistical evaluation revealed that only CF specimens decreased the AL nanohardness after 1 year of storage. The hybrid layer (HL) produced with CF and SB, resulted in lower nanohardness values for CAD than SD, which reduces after 1 year storage, for all surface treatments. Interface SEM analysis revealed that all adhesive interfaces, especially those in CAD, have experienced degradation after 1 year of storage. Laser 80 and Laser 50 promotes surface ablation characteristics in...


Subject(s)
Humans , Male , Female , Dentin/physiology , Microscopy, Electron, Scanning/methods , Microscopy, Electron, Scanning
4.
Braz. dent. sci ; 17(1): 39-44, 2014. tab
Article in English | LILACS, BBO | ID: lil-728107

ABSTRACT

Objective: The aim of this study was to detect the influence of application mode of cleansing agents, on enamel and dentin during the adhesion process of a one-step self-etching adhesive system. Materials & Methods: 24 human molars were sectioned into halves along the long axis for enamel and dentin tests. The cleansing agents used were 3% hydrogen peroxide (group HP), anionic detergent (group AD), and antiseptic solution (group AS). In the experiment, these agents were applied with (active) and without friction (passive) on enamel and dentin surfaces. A one-step self-etching adhesive system (Clearfil S3 Bond) was applied on dental surface and composite resin cylinders were built using Tygon tubing molds. After 24 h, μSBS (microshear) test (1 mm/ min) and fracture analysis were performed. Results: There was no statistically significant difference in bond strength values regarding the application mode of cleansing agents for enamel and dentin (p ≥ 0.05). The use of antiseptic solution on enamel resulted in bond strength results significantly higher when compared with HP and AD (p = 0.014). Conclusions: Regarding bond strength to enamel and dentin using one-step self-etching adhesive system, application mode of the cleansing agents used in this study presented the same behavior. Antiseptic solution applied on enamel before the application of a one-step adhesive system increased bond strength performance


Objetivo: O objetivo deste estudo foi detectar a influência do modo de aplicação de agentes de limpeza, em esmalte e dentina durante o processo de adesão de um sistema adesivo auto-condicionante de passo único. Materiais e Métodos: 24 molares humanos foram seccionados em duas metades ao longo do eixo para testes de esmalte e dentina. Os agentes de limpeza utilizados foram: peróxido de hidrogênio 3% (grupo HP), detergente aniônico (grupo AD) e solução anti-séptica (grupo AS). No experimento, esses agentes foram aplicados com fricção (ativa) e sem fricção (passiva) em superfícies de esmalte e dentina. O sistema adesivo autocondicionante de um passo (Clearfil S3 Bond) foi aplicado na superfície dental e cilindros de resina composta foram construídas usando moldes (Tubos Tygon). Após 24 h, o teste de microcisalhamento (1 mm / min) e análise de fratura foram executados. Resultados: Não houve diferença estatisticamente significante nos valores de resistência de união em relação ao modo de aplicação de agentes de limpeza para esmalte e dentina (p ≥ 0,05). O uso de solução anti-séptica no esmalte resultou em resultados de resistência de união significativamente maior quando comparada com HP e AD (p = 0,014). Conclusões: Em relação à resistência de união ao esmalte e dentina utilizando sistema adesivo autocondicionante de passo único, o modo de aplicação dos agentes de limpeza utilizados neste estudo apresentaram o mesmo comportamento. A aplicação da solução anti-séptica aplicada sobre o esmalte antes da aplicação de um sistema adesivo de passo único apresentou melhor desempenho de resistência de união.


Subject(s)
Humans , Dental Cements , Hydrogen Peroxide
5.
Braz. j. oral sci ; 12(2): 119-124, Apr.-June 2013. ilus
Article in English | LILACS, BBO | ID: lil-694430

ABSTRACT

Aim: To evaluate the leakage on Er,Cr:YSGG laser- and bur- prepared Class V cavities restoredwith a silorane-based composite resin using different insertion techniques Methods: 40 cavitieswere outlined according to: the type of instrument [Er,Cr:YSGG laser (3.0 W power, energy perpulse of 150 mJ, fluence of 53.57J/cm2, pulse duration of 140-200 μs, 20 Hz repetition rate and55/65% air/water spray) or diamond bur]; and the type of filling technique (bulk increment orincremental). Four experimental groups were obtained (n=10): G1- diamond bur (DB) andincremental (I); G2- DB and bulk increment (BI); G3- Er,Cr:YSGG and I; and G4- Er,Cr:YSGGand BI. Specimens were restored with a silorane-based composite resin (Filtek P90, 3M/ESPE),subjected to 500 thermal cycles, sealed, infiltrated with 2% (w/v) methylene blue and sectioned inhalves. Specimen analysis was scored based on a scale. Statistical analyses were done usingthe Kruskal-Wallis and Student Newman-Keuls tests (α=0.05). Results: Statistically significantdifferences were observed between G2 and G4 (p=0.003) and between G1 and G2 (p=0.028).The filling technique did not influence the pattern of dye leakage in the cavity walls (p=0.151).Conclusions: Less leakage was observed when Er,Cr:YSGG cavities were restored withsilorane-based composite resin, using the bulk increment technique. Nevertheless, cavities doneusing diamond bur have less leakage only when incrementally restored.


Subject(s)
Composite Resins , Dental Leakage , Lasers , Polymerization , Tooth Preparation
6.
Article in Portuguese | LILACS, BBO | ID: lil-676119

ABSTRACT

Atualmente, a fim de se avaliar a resistência de união entre substrato e material restaurador, o teste mais utilizado é o ensaio por microtração. Todavia, na literatura encontram-se diversas maneiras de se realizar esse teste, desde a seleção da amostra até a análise dos resultados obtidos. Nesta revisão de literatura serão apresentados os principais métodos para realização do teste de microtração, bem como os fatores que podem afetar nos resultados obtidos por este ensaio


Currently, in order to evaluate the bond strength between the dental substrate and the restorative material, microtensile bond strength is the most used test. The purpose of this review is to describe all of the various modifications of the microtensile bond test in one paper. In the literature there are several ways to perform this test, since the selection of the sample to the analysis of the results. In this literature review will be presented the main methods for microtensile testing, as well as factors that may affect the results obtained by this test. The microtensile test methods offer versatility that cannot be achieved by conventional methods, It is up to the researcher to choose the test characteristics that best suits your needs


Subject(s)
Tensile Strength , Dental Enamel , Dentin
7.
Braz. dent. sci ; 16(4): 105-112, 2013. ilus
Article in English | LILACS, BBO | ID: lil-728088

ABSTRACT

Objective: Pulp calcification can compromise tooth color and negatively affect esthetics. Definitive treatment for discolored anterior teeth with calcification is usually provided by endodontic treatment with the use of internal and external bleaching agents, as necessary. This article presents the conservative management of a vital tooth with an obliterated pulp chamber that led to changes in tooth color. The benefits and limitations of the use of in-office and home supervised bleaching techniques are discussed


Objetivo: Uma calcificação pulpar pode comprometer a cor dos dentes e afetar negativamente a estética dental. O tratamento de escolha para um dente anterior escurecido e com calcificação pulpar é geralmente o tratamento endodôntico seguido de clareamento interno e externo, se necessário. Esse artigo relata um caso clínico de um tratamento conservador de um dente vital com câmera pulpar obliterada que ocasionou alteração de cor do elemento dental. Os benefícios e as limitações do uso das diferentes técnicas de clareamento dental utilizadas também foram discutidos.


Subject(s)
Humans , Dental Pulp Calcification , Tooth Bleaching
8.
São Paulo; s.n; 2012. 80 p. ilus, tab, graf. (BR).
Thesis in Portuguese | LILACS, BBO | ID: biblio-866132

ABSTRACT

Este estudo se propôs a validar um protocolo para obtenção de dentina afetada por cárie, através do processo in vitro de desmineralização de dentina humana induzida por biofilme de Streptoccocus mutans (método microbiológico). A validação do protocolo foi realizada através de diferentes métodos diagnósticos: inspeção visual, radiografia digital, fluorescência a laser e sistema de tomografia por coerência óptica (OCT). Foram utilizados 48 molares humanos (24 erupcionados e 24 inclusos), que foram lixados na sua face oclusal para remoção do esmalte com exposição da dentina oclusal superficial, obtendo uma superfície plana. As raízes dos dentes foram removidas e os espécimes foram cortados no sentido vestibulo-lingual obtendo-se dois fragmentos que foram distribuídos aleatoriamente nos grupos experimentais. Os espécimes foram protegidos com verniz ácido resistente na metade da face oclusal (controle) e na outra metade foi produzida a lesão de cárie. Os grupos experimentais foram compostos a partir de 2 fatores de variação: tempo de desafio cariogênico (7, 14 e 21 dias) e tipo de dentina (proveniente de dentes inclusos ou erupcionados). Assim, formaram-se 6 grupos experimentais: com dentina proveniente de dentes erupcionados G1 (7 dias de desafio cariogênico), G2 (14 dias), G3 (21 dias); e com dentina proveniente de dentes inclusos G4 (7 dias), G5 (14 dias) e G6 (21 dias). Após os diferentes tempos de desafio cariogênico, os espécimes foram avaliados nas suas porções sadia e afetada por cárie utilizando diferentes métodos de diagnóstico e os resultados comparados. Através da inspeção visual comprovou-se a formação de dentina afetada por cárie uma vez que características do tecido como coloração amarelada, perda de brilho superficial e consistência borrachóide foram observadas. A radiografia digital foi capaz de detectar a presença de imagem sugestiva de lesão de cárie através de imagem radiolúcida.


Três examinadores calibrados visualizaram todas as imagens obtidas através da inspeção visual e da radiografia digital e foram capazes de distinguir o tecido hígido do afetado por cárie. Foi aplicado o teste estatístico Exato de Fischer com nível de significância de 5% que confirmou não haver diferença entre os grupos tanto na inspeção visual (G1 e G4 - p=0,6, G2 e G5 - p=1 e G3 e G6 - p=1)como para a radiografia digital (G1 e G4 - p=1, G2 e G5 - p=1 e G3 e G6 - p=1). Tanto os valores de fluorescência a laser quanto os de profundidade de desmineralização (OCT) foram submetidos ao teste estatístico Análise de Variância (ANOVA) (p<0,05). Em relação aos valores obtidos via fluorescência a laser, pode-se observar que houve diferença estatisticamente significante para o fator tipo de substrato (p=0.001), sendo que os espécimes provenientes de dentes erupcionados apresentaram maior valor de fluorescência em relação aos espécimes provenientes de dentes inclusos. Quanto ao OCT, pode-se observar que não houve diferença estatisticamente significante para o fator tipo de substrato (p=0,163), para o fator tempo de desafio cariogênico (p=0,512) e para a interação entre os fatores (p=0,148). Por fim, eletromicrografias foram obtidas através de Microscopia Eletrônica de Varredura que confirmaram a presença do tecido afetado por cárie produzido artificialmente em todos os tempos de desmineralização testados, no entanto observou-se desmineralização superficial mais uniforme em dentina afetada por cárie proveniente de dentes inclusos. Assim, podemos concluir que 7 dias de desafio cariogênico é suficiente para obtenção de dentina afetada padronizada a ser utilizada em ensaios laboratoriais e que dentes inclusos forneceram um substrato dentinário mais adequado para utilização no protocolo proposto.


The aim of this in vitro study was to validate a protocol for obtaining standard caries affected-dentine by dentine demineralization process induced by Streptoccocus mutans biofilm (microbiological approach). Validation methods performed were optical coherence tomography (OCT), visual inspection, laser fluorescence and digital radiography. As all methods were nondestructive, all analysis were performed in the same specimens. A total of 48 human molars (24 erupted and 24 unerupted) were grounded in the occlusal surface to remove enamel and obtain a flat dentin surface. The roots of the teeth were removed and the specimens were cut in the bucco-lingual direction yielding two fragments that were randomized into experimental groups. The dental fragments were protected with acid resistant varnish in half of the occlusal surface (control) and in the other half was produced carious lesions. The experimental groups were composed from two variation factors: period of cariogenic challenge (7, 14 and 21 days) and type of dentin (from erupted or unerupted teeth). Thus six experimental groups were formed: with dentin from erupted teeth - G1 (7 days of cariogenic challenge), G2 (14 days), G3 (21 days), and with dentin from unerupted teeth - G4 (7 days), G5 (14 days) and G6 (21 days). After different periods of cariogenic challenge, the specimens were evaluated on their healthy and caries-affected portions using different diagnostic methods and the results were compared. Visual inspection proved the formation of caries affected dentin as characteristics of the tissue as yellowing, loss of surface gloss and consistency elastic were observed. The digital radiography was able to detect the presence of radiolucent image, suggesting caries...


Subject(s)
Humans , Male , Female , Dental Caries/diagnosis , Dentin/physiology , Tooth Demineralization/diagnosis
9.
Braz. oral res ; 25(5): 407-413, Sept.-Oct. 2011. ilus, tab
Article in English | LILACS | ID: lil-601879

ABSTRACT

The purpose of this study was to evaluate the degree of demineralization of artificially induced caries-affected human dentin by an in vitro microbiological method. The occlusal surfaces of 6 human molar teeth were abraded until a flat surface was obtained, and the enamel was removed to expose the occlusal dentin surface. These teeth were sectioned in 12 halves in the vestibular-lingual direction and divided into 3 groups according to the period length of the microbiological essay (n = 4): G1, 7 days; G2, 14 days; and G3, 21 days. The surfaces of all specimens were protected by an acid-resistant nail varnish, except for a window where the caries lesion was induced by a Streptoccocus mutans biofilm in a batch-culture model supplemented with 5 percent sucrose. The specimens were then analyzed by optical coherence tomography (OCT) with a super-luminescent light diode (Λ = 930 nm) with 6.0-µm lateral and longitudinal resolution (in the air). Qualitative and quantitative results (images and average dentin demineralization, respectively) were obtained. The mean demineralization depths were (µm) 235 ± 31.4, 279 ± 14, and 271 ± 8.3 in groups 1, 2, and 3, respectively. In addition, no significant change was observed in the lesion mean depth from 7 days of cariogenic challenge on. In conclusion, OCT was shown to be an efficient and non-invasive method to detect the depths of lesions caused by demineralization. Further, a seven-day demineralization time was considered sufficient for caries-affected dentin to be obtained.


Subject(s)
Humans , Dental Caries Activity Tests/methods , Dental Caries/diagnosis , Dentin/ultrastructure , In Vitro Techniques , Tomography, Optical Coherence/methods , Biofilms , Dentin/chemistry , Surface Properties , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL