Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Journal of Clinical Hepatology ; (12): 2811-2814, 2020.
Article in Chinese | WPRIM | ID: wpr-837654

ABSTRACT

A large number of studies in recent years have shown that long non-coding RNAs (lncRNAs) play an important regulatory role in the progression of liver fibrosis. This article briefly describes the definition, classification, and biological functions of lncRNAs and summarizes recent reports on the regulatory role of lncRNAs in liver fibrosis by acting as competitive endogenous RNA, including downregulated maternally expressed gene 3, growth arrest-specific transcript 5, and long intergenic non-coding RNA-p21 and upregulated lung adenocarcinoma-associated transcript 1, lncRNA-activated by transforming growth factor beta, plasmacytoma variant translocation 1, homeobox transcript antisense RNA, lncRNA-H19, and small nuclear RNA host gene 7, so as to provide insights into the diagnosis of liver fibrosis, the screening of therapeutic targets, and the development of clinical treatment regimens for the reversal of liver fibrosis.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 434-438, 2018.
Article in Chinese | WPRIM | ID: wpr-708083

ABSTRACT

Objective To evaluate the incidental irradiation to the axillary levels Ⅰ,Ⅱ and Ⅲduring the whole breast radiotherapy after breast conserving surgery(BCS)without axillary lymph node dissection(ALND)in breast cancer(BC)patients.Methods A retrospective analysis was performed on the consecutive 42 cases of T1-2N0M0stage BC patients with sentinel lymphnode biopsy(SLNB)and BCS but without ALND.The axillary lymph nodes of Ⅰ,Ⅱ and Ⅲ were delineated according to RTOG atlas guideline.Three radiotherapy plans including conventional tangential field(CTF),three-dimensional conformal radiotherapy(3D-CRT)and forward-planned intensity-modulated radiotherapy(IMRT)for whole breast irradiation were devised for each case.The Prescription dose was 50 Gy per 25 fractions.Doses to axillary levels(Ⅰ-Ⅲ)were evaluated.Results The mean doses delivered to axillary by the three techniques(CTF,3D-CRT and IMRT)were(40.1 ±6.8),(35.4 ±8.3),(32.9 ±7.0)Gy for level Ⅰ(F=10.269,P<0.05),(33.2 ±7.1),(30.6 ±6.7),(30.4 ±7.0)Gy for level Ⅱ(P>0.05)and(9.6 ±6.8),(6.4 ±4.5),(5.2 ±3.7)Gy for level Ⅲ(F =8.377,P <0.05),respectively.V50(volume receiving 50 Gy)for the three techniques were 21.3%,27.6%,9.6%for level Ⅰ(F=13.161,P<0.05),12.9%,15.9%,8.3%for level Ⅱ(F=2.750,P<0.05)and 0.4%,0.1%and 0%for level Ⅲ(P>0.05),respectively.Conclusions The doses coverage to axillary levelsⅠ-Ⅲwere all limited in the three techniques.Therefore,it is necessary to assess the risk of axillary lymph node metastasis adequately to develop individualized radiotherapy plans.

SELECTION OF CITATIONS
SEARCH DETAIL