Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
J. appl. oral sci ; 28: e20200343, 2020. graf
Article in English | LILACS, BBO | ID: biblio-1143144

ABSTRACT

Abstract An important factor affecting the biomechanical behavior of implant-supported reconstructions is the implant-abutment misfit. Objective: This study evaluated the misfit between Ti-Base abutments and implants by means of polyvinyl siloxane replica technique using microcomputed tomography (μCT). Methodology: Volumetric and linear (central and marginal) gaps of four Ti-base abutments (n=10/group): (i) Odontofix LTDA (OD), (ii) Singular Implants (SING), (iii) EFF Dental Components (EFF), and (iv) Control Group (S.I.N implants) compatible with an implant system (Strong SW, S.I.N Implants) were measured using μCT reconstructed polyvinyl siloxane replicas. Results: The results showed significantly lower volume gap for Control S.I.N (0.67±0.29 mm3) and SING (0.69±0.28 mm3) Ti-base abutments relative to OD (1.42±0.28 mm3) and EFF groups (1.04±0.28 mm3) (p<0.033), without significant difference between them (p=0.936). While gap values were homogenous in the central region, EFF presented a significantly higher marginal gap. Accordingly, the Control S.I.N and Singular Ti-base abutments showed improved volumetric and marginal fit relative to Odontofix and EFF. Conclusion: The method of manufacturing abutments influenced the misfit at the implant-abutment interface.


Subject(s)
Dental Implants , Dental Abutments , Titanium , Replica Techniques , X-Ray Microtomography , Dental Implant-Abutment Design
2.
J. appl. oral sci ; 25(3): 282-289, May-June 2017. tab, graf
Article in English | LILACS, BBO | ID: biblio-893629

ABSTRACT

Abstract Zirconia-reinforced lithium silicate (ZLS) is a ceramic that promises to have better mechanical properties than other materials with the same indications as well as improved adaptation and fracture strength. Objective In this study, marginal and internal misfit and fracture load with and without thermal-mechanical aging (TMA) of monolithic ZLS and lithium disilicate (LDS) crowns were evaluated. Material and methods Crowns were milled using a computer-aided design/computer-aided manufacturing system. Marginal gaps (MGs), absolute marginal discrepancy (AMD), axial gaps, and occlusal gaps were measured by X-ray microtomography (n=8). For fracture load testing, crowns were cemented in a universal abutment, and divided into four groups: ZLS without TMA, ZLS with TMA, LDS without TMA, and LDS with TMA (n=10). TMA groups were subjected to 10,000 thermal cycles (5-55°C) and 1,000,000 mechanical cycles (200 N, 3.8 Hz). All groups were subjected to compressive strength testing in a universal testing machine at a crosshead speed of 1 mm/min until failure. Student's t-test was used to examine misfit, two-way analysis of variance was used to analyze fracture load, and Pearson's correlation coefficients for misfit and fracture load were calculated (α=0.05). The materials were analyzed according to Weibull distribution, with 95% confidence intervals. Results Average MG (p<0.001) and AMD (p=0.003) values were greater in ZLS than in LDS crowns. TMA did not affect the fracture load of either material. However, fracture loads of ZLS crowns were lower than those of LDS crowns (p<0.001). Fracture load was moderately correlated with MG (r=-0.553) and AMD (r=-0.497). ZLS with TMA was least reliable, according to Weibull probability. Conclusion Within the limitations of this study, ZLS crowns had lower fracture load values and greater marginal misfit than did LDS crowns, although these values were within acceptable limits.


Subject(s)
Organometallic Compounds/chemistry , Succinates/chemistry , Zirconium/chemistry , Dental Marginal Adaptation , Dental Prosthesis, Implant-Supported/methods , Dental Restoration Failure , Crowns , Reference Values , Surface Properties , Time Factors , Tooth Fractures , Materials Testing , Reproducibility of Results , Analysis of Variance , Dental Prosthesis Design , Computer-Aided Design , Statistics, Nonparametric , Compressive Strength , X-Ray Microtomography
3.
Dent. press implantol ; 9(1): 58-65, Jan.-Mar.2015. ilus, tab
Article in Portuguese | LILACS | ID: lil-777965

ABSTRACT

Com a finalidade de correção de defeitos ósseos, diversos materiais sintéticos têm sido utilizados, entre os quais está o sulfato de cálcio. Objetivo: o objetivo do presente estudo foi avaliar, in vitro, a bioatividade do sulfato de cálcio em fluido corpóreo simulado (SBF). Métodos: quatro corpos de prova foram preparados em matrizes de policloreto de vinila (PVC) circulares, misturando-se o sulfato de cálcio nas proporções de líquido/pó recomendadas pelo fabricante, com água destilada. As amostras ficaram imersas em 50ml de SBF, a 36,5ºC, por até 21 dias, sendo que a solução foi renovada a cada três dias. A bioatividade foi verificada por meio de Espectroscopia no Infravermelho por Transformada de Fourier (FTIR). Resultados: no teste de bioatividade in vitro, a análise por FTIR detectou a presença de apatita sobre o substrato de sulfato de cálcio, demonstrando tratar-se de um material bioativo. Além disso, foi observada uma redução expressiva do tamanho da amostra vinculada ao processo de reabsorção. Conclusão: dentro das limitações do estudo, pode-se concluir que o sulfato de cálcio é um material bioativo e rapidamente reabsorvido...


Several types of synthetic material have been used to correct bone defects, among which is calcium sulfate. Objective: the present in vitro study aimed at assessing the bioactivityof calcium sulfate in simulated body fluid (SBF). Methods: four specimens were prepared in polyvinyl chloride (PVC) circle matrices by mixing calcium sulfate with distilled water, as recommended by the manufacturer. Samples were immersed in 50 ml of SBF, at 36.5 ºC, for no longer than 21 days. The solutionwas renewed every three days. Bioactivity was assessed by means of Fourier transform infrared spectroscopy (FTIR). Results: The in vitro bioactivity test, carried out by means of FTIR analysis, revealed the presence of apatite formation over calcium sulfate substrate, thereby proving it to be a bioactive material. In addition, there was significant reduction in the size of the sample, which was associated with the process of resorption. Conclusion: within the limitations of the present study, it is reasonable to conclude that calcium sulfate is a bioactive material which is quickly absorbed...


Subject(s)
Bone Substitutes , Spectroscopy, Fourier Transform Infrared , Calcium Sulfate/therapeutic use , Biocompatible Materials , Materials Testing
4.
Braz. oral res. (Online) ; 29(1): 1-6, 2015. tab
Article in English | LILACS | ID: lil-777191

ABSTRACT

Current Brazilian law regarding water fluoridation classification is dichotomous with respect to the risks of and benefits for oral diseases, and fluoride (F) concentrations less than 0.6 or above 0.8 mg F/L are considered outside the normal limits. Thus, the law does not consider that both caries and fluorosis are dependent on the dosage and duration of fluoride exposure because they are both chronic diseases. Therefore, this study evaluated the quality of water fluoridation in Maringá, PR, Brazil, considering a new classification for the concentration of F in water the supply, based on the anticaries benefit and risk of fluorosis (CECOL/USP, 2011). Water samples (n = 325) were collected monthly over one year from 28 distribution water networks: 20 from treatment plants and 8 from artesian wells. F concentrations were determined using a specific ion electrode. The average F concentration was 0.77 mg F/L (ppm F), ranging from 0.44 to 1.22 mg F/L. Considering all of the water samples analyzed, 83.7% of them presented from 0.55 to 0.84 mg F/L, and according to the new classification used, they would provide maximum anticaries benefit with a low risk of fluorosis. This percentage was lower (75.4%) in the water samples supplied from artesian wells than from those distributed by the treatment plant (86%). In conclusion, based on the new classification of water F concentrations, the quality of water fluoridation in Maringá is adequate and is within the range of the best balance between risk and benefit.


Subject(s)
Humans , Dental Caries/prevention & control , Fluoridation , Fluorides/analysis , Fluorosis, Dental/prevention & control , Water/chemistry , Brazil , Cities , Public Health , Reference Standards , Risk Assessment , Time Factors
5.
Dent. press implantol ; 8(4): 16-26, Oct.-Dec. 2014. ilus
Article in Portuguese | LILACS, BBO | ID: lil-762303

ABSTRACT

Introdução: os problemas funcionais, estéticos e psicológicos decorrentes do edentulismo têm levado a uma busca crescente por reabilitação bucal com próteses sobre implantes. Esse tipo de reabilitação necessita de um planejamento meticuloso, especialmente para os casos de maxila edêntula com prótese fixa sobre implantes, em decorrência da anatomia dessa região. Objetivo: o objetivo do presente caso clínico é descrever a reabilitação de uma maxila edêntula com prótese total fixa implantossuportada, cuja infraestrutura recebeu elementos metalocerâmicos cimentados individualmente.


Introduction: Functional, aesthetic and psychological issues arising from edentulism have led to a growing search for oral rehabilitation with implant-supported prostheses. This type of rehabilitation requires detailed planning, especially for treating edentulous maxilla with implantsupported fixed prostheses due to the anatomy of this region. Objective: The aim of this case report is to describe the rehabilitation of an edentulous maxilla with implantsupported full fixed prosthesis of which framework received metal-ceramic elements individually cemented.


Subject(s)
Humans , Male , Jaw, Edentulous/rehabilitation , Clinical Protocols , Dental Prosthesis, Implant-Supported , Denture, Complete, Upper , Brazil , Cementation , Maxilla , Metal Ceramic Alloys
SELECTION OF CITATIONS
SEARCH DETAIL