1.
Journal of Medical Biomechanics ; (6): E849-E854, 2021.
Article in Chinese | WPRIM | ID: wpr-920693

ABSTRACT

Objective To study the effects of selecting different fixing segments on biomechanical characteristics of the spine during the treatment of early onset scoliosis(EOS) by growing rod technique. Methods By using finite element method, four spine models (C6-S1 segments) fixed by growing rod were established: preoperative model, T1-L4 fixed model, T2-L4 fixed model, T3-L4 fixed model. Then 7 N·m torque load and 1 rad angular displacement load were applied on superior surface of C6 segment to analyze biomechanical characteristics for adjacent structure of the fixed vertebral body. Results The whole spinal range of motion (ROM) decreased significantly after operation. When the T2-L4 segment was fixed, the spine activity was mostly restricted, the compensatory activity of adjacent vertebrae increased significantly, and the intervertebral disc stress increased significantly. Conclusions When T2 segment is selected as the upper instrumented segment, the risk of proximal junctional kyphosis and spinal degeneration is the highest, which should be avoided in clinical surgery.

2.
Journal of Medical Biomechanics ; (6): E320-E325, 2018.
Article in Chinese | WPRIM | ID: wpr-803714

ABSTRACT

Objective To study the effect of vibration environments on patients with posterior lumbar interbody fusion in daily life. Methods Finite element models of an intact lumbar spine and a postoperative model with fixed L4-5 segments were established. Subsequently, a 40-kg mass point was applied to the upper end plate of the L1 segment to perform a modal analysis. Results In comparison with an intact lumbar spine, the resonance frequency for each order of the whole lumbar spine was reduced after posterior lumbar interbody fusion, and the primary movement of the corresponding modes were also changed. The first two inherent frequencies of the modal in the fusion model were 2.94 Hz and 3.81 Hz, which were close to the vibration frequencies in daily life. In the first three order vibrations, the mode amplitudes of the posterior elements for the L2 and L3 segments increased in the fusion model, which could increase the risk of postoperative degeneration at such locations. In addition, the vibration amplitude of the intervertebral disc of the L3-4 segments clearly increased, particularly at the part of the disc near the L3 vertebral body, which could lead to increased stress and strain and further accelerate its degeneration. Conclusion sBased on the modal analysis of a lumbar spine after posterior lumbar interbody fusion, the investigation of the vibration characteristics of the postoperative lumbar spine will provide some theoretical guidance for the recovery and healthy life of the patients after the corresponding surgery.

3.
Chinese Journal of Surgery ; (12): 692-696, 2014.
Article in Chinese | WPRIM | ID: wpr-336695

ABSTRACT

<p><b>OBJECTIVE</b>To study the effect of length of cervical anterior fusion on adjacent levels by Biomechanical test.</p><p><b>METHODS</b>Six fresh-frozen human cervical specimens were used in this study. The specimens were tested in flexion, extension, bending and rotation on a spine 3D test system. The specimens were tested intact and then underwent a single-level anterior cervical discectomy and fusion (ACDF) at the C4-5 first, a double-level fusion at the C4-6, and finally extended to triple-level at the C4-7, Based on a hybrid test method. Changes in overall range of motion (ROM), segmental motion and facet joints pressure during flexion, extension, bending and rotation were measured and statistically analyzed.</p><p><b>RESULTS</b>The overall ROM of the entire spinal construct decreased progressively as the single-level fixation extending to 2-level and 3-level (P < 0.05). A progressive increase in ROM above (C3-4) the fused motion segment units (MSUs) was found during flexion, extension and bending (P < 0.05). In bending and extension, a same result was recorded on the average pressure and max pressure of C3-4 facet joints (P < 0.05).</p><p><b>CONCLUSIONS</b>This study has demonstrated that the biomechanics at adjacent levels to a cervical spine fusion are altered and that there was progressively increased adjacent segment motion and stress as a single-level ACDF extended to a 3-level fusion, which might lead to the acceleration of adjacent segment degeneration.</p>


Subject(s)
Humans , Biomechanical Phenomena , Cadaver , Cervical Vertebrae , General Surgery , Diskectomy , Methods , Range of Motion, Articular , Rotation , Spinal Fusion , Methods
4.
Chinese Journal of Medical Instrumentation ; (6): 44-48, 2013.
Article in Chinese | WPRIM | ID: wpr-342888

ABSTRACT

In view of the shortage of medical equipment road transportation simulation platform, we put forward a road transportation simulation method based on 6-DOF parallel robots. A 3D road spectrum model was built by the improvement of the harmonic superposition method. The simulation model was then compared with the standard model to verify its performance. Taking the road spectrum as the excitation, we could get the robot motion data to control the parallel robot through the S-shaped linear interpolation of the absolute position. It can simulate the movement of vehicles with different speed under various road conditions efficiently and accurately.


Subject(s)
Equipment Design , Motor Vehicles , Robotics , Transportation , Methods
5.
Chinese Journal of Medical Instrumentation ; (6): 50-52, 2011.
Article in Chinese | WPRIM | ID: wpr-330522

ABSTRACT

This paper designed a ventilator control system to control proportional valves and motors. It used LabVIEW to control the object mentioned above and design ,validate, evaluate arithmetic, and establish hardware in loop platform. There are two system' s hierarchies. The high layer was used to run non-real time program and the low layer was used to run real time program. The two layers communicated through TCP/IP net. The program can be divided into several modules, which can be expanded and maintained easily. And the harvest in the prototype designing can be seamlessly used to embedded products. From all above, this system was useful in employing OEM products.


Subject(s)
Man-Machine Systems , Software , Software Design , Ventilators, Mechanical