Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Arq. bras. cardiol ; 103(6): 485-492, 12/2014. tab, graf
Article in English | LILACS | ID: lil-732164

ABSTRACT

Background: Left ventricular (LV) diastolic dysfunction is associated with new-onset atrial fibrillation (AF), and the estimation of elevated LV filling pressures by E/e' ratio is related to worse outcomes in patients with AF. However, it is unknown if restoring sinus rhythm reverses this process. Objective: To evaluate the impact of AF ablation on estimated LV filling pressure. Methods: A total of 141 patients underwent radiofrequency (RF) ablation to treat drug-refractory AF. Transthoracic echocardiography was performed 30 days before and 12 months after ablation. LV functional parameters, left atrial volume index (LAVind), and transmitral pulsed and mitral annulus tissue Doppler (e' and E/e') were assessed. Paroxysmal AF was present in 18 patients, persistent AF was present in 102 patients, and long-standing persistent AF in 21 patients. Follow-up included electrocardiographic examination and 24-h Holter monitoring at 3, 6, and 12 months after ablation. Results: One hundred seventeen patients (82.9%) were free of AF during the follow-up (average, 18 ± 5 months). LAVind reduced in the successful group (30.2 mL/m2 ± 10.6 mL/m2 to 22.6 mL/m2 ± 1.1 mL/m2, p < 0.001) compared to the non-successful group (37.7 mL/m2 ± 14.3 mL/m2 to 37.5 mL/m2 ± 14.5 mL/m2, p = ns). Improvement of LV filling pressure assessed by a reduction in the E/e' ratio was observed only after successful ablation (11.5 ± 4.5 vs. 7.1 ± 3.7, p < 0.001) but not in patients with recurrent AF (12.7 ± 4.4 vs. 12 ± 3.3, p = ns). The success rate was lower in the long-standing persistent AF patient group (57% vs. 87%, p = 0.001). Conclusion: Successful AF ablation is associated with LA reverse remodeling and an improvement in LV filling pressure. .


Fundamento: A disfunção diastólica do ventrículo esquerdo (VE) está associada a novos episódios de fibrilação atrial (FA), e a estimativa das pressões de enchimento do VE através da razão E/e' está relacionada a um pior prognóstico em pacientes com FA. Entretanto, não se sabe se a restauração do ritmo sinusal pode reverter este processo. Objetivo: Avaliar o impacto da ablação da FA na estimativa da pressão de enchimento do VE. Métodos: Um total de 141 pacientes foi submetido à ablação por radiofrequência (RF) para o tratamento da FA refratária a drogas. Foi realizado ecocardiograma transtorácico 30 dias antes e 12 meses após a ablação. Foram avaliados os parâmetros funcionais do VE, volume do átrio esquerdo indexado (VAEi) e Doppler transmitral pulsado e Doppler tecidual do anel mitral (e' e E/e'). Dezoito pacientes apresentavam FA paroxística, 102 persistente e 21 pacientes FA persistente de longa duração. O acompanhamento incluiu ECG e monitoramento pelo sistema Holter 24h, 3, 6 e 12 meses após a ablação. Resultados: Cento e dezessete pacientes (82,9%) não apresentaram FA durante o acompanhamento (média de 18 meses ± 5 meses). O VAEi apresentou redução significativa no grupo com sucesso (30,2 mL/m2 ± 10,6 mL/m2 para 22,6 mL/m2 ± 1,1 mL/m2, p < 0,001) em comparação ao grupo sem sucesso (37,7 mL/m2 ± 14,3 mL/m2 para 37,5 mL/m2 ± 14,5 mL/m2, p = ns). A melhora da estimativa da pressão de enchimento do VE, avaliada através da redução na razão E/e', foi observada apenas após ablação com sucesso (11,5 ± 4,5 vs. 7,1 ± 3,7, p < 0,001), não sendo observada em pacientes com FA recorrente (12,7 ± 4,4 vs. 12 ± 3,3, p = ns). A taxa de ...


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Atrial Remodeling/physiology , Catheter Ablation/methods , Ventricular Function, Left/physiology , Analysis of Variance , Atrial Fibrillation , Echocardiography , Electrocardiography, Ambulatory , Follow-Up Studies , Observer Variation , Prospective Studies , Stroke Volume/physiology , Time Factors , Treatment Outcome
2.
Rev. bras. ecocardiogr. imagem cardiovasc ; 26(2): 105-110, abr.-jun. 2013. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-678704

ABSTRACT

Introdução: O aumento do átrio esquerdo (AE) está diretamente relacionado a disfunção diastólica do VE(VD) e ambos estão associados a ocorrência de fibrilação atrial (FA). Embora o diâmetro (DAE) seja mundialmente usado como medida do AE, muitas evidencias mostram que o volume indexado para a superficie corporea (indVAE) é mais acurado. Objetivo: Avaliar a correlação entre DAE e IndVAE em pacientes (pt) com DD. Material e Métodos: Dentre 892 pacientes encaminhados ao ecocardiograma, (ECO) de uma clínica terciaria no DF, entre janeiro de 2008 a junho de 2009, foram selecionados 540 com addos clínicos e ecocardiograficos, dos quais foram excluidos 21, devido a idade < 18 anos e 18 pacientes com lesão valvar mitral > discreta. A função diastólica foi considerada, significativamente, anormal se E/e'>-15 (elevação das pressões de encihmento ventricular esquerdo). A concordância entre as medidas de DAE e IndVAE foi avaliada da seguinte forma concordante (IndVAE<- 40mm ou IndVAE > 40); e discordante (indVAE<- 32 e DAE > 40 ou IndVAE > 32 e DAE <- 40.). Resultados: Dos 501 pacientes estudados, 33 (6,6%) tinham E/e' >- 15 e 468 (93,4%) E/e' < 15. Houve boa correlação entre DAE e IndVAE tanto para pacientes com E/e' >- 15 (r=0,57), quando para pacientes com E/e' < 15 (r=0,62). A discordância entre DAF e IndVAE foi maior nos pacientes...


Background: Increased left atrial (LA) is directly related to LV diastolic dysfunction (DD), and both are associated with atrial fibrillation (AF). Although the diameter (LAD) is used as a measure of LA, many evidences show that LA volume index (iLAV) is more accurate. Objective: To evaluate the correlation between LAD and iLAV in patients (pt) with DD. Material and Methods: Among 892 pt referred to the echocardiography laboratory of a tertiary clinic, from Jan/08 to June/09, 540 pt with clinical and echocardiographic data were selected and 21 were excluded for being <18yo and 18 pt presenting more than mild mitral valve lesion. Diastolic function was considered abnormal when E/e¡¯ ratio ¡Ý 15 (elevated left ventricular filling pressures). Agreement between measures of LAD and iLAV was evaluated: agreement if iLAV ¡Ü 32ml/m2 and LAD ¡Ü 40mm or iLAV > 32 and LAD > 40; and disagreement if iLAV ¡Ü 32 and LAD > 40 or iLAV > 32 and LAD ¡Ü 40. Results: Of 501 pt, 33 (6.6%) presented E/e¡¯ ratio ¡Ý 15 and 468 (93.4%) < 15. There was a good correlation between LAD and iLAV in both patients with E/e¡¯ ¡Ý 15 (r = 0.57), and E/e¡¯ < 15 (r = 0.62). The disagreement between LAD and iLAV was higher in p with E/e¡¯ ¡Ý 15 (21.2% vs 9% - p <0.0001). Clinical and echocardiographic data were, respectively, for E/e¡¯ ¡Ý15 and E/e¡¯ < 15: male 54.5% vs 45.5% (p = ns), age 73.2 ¡À 12.4 vs 50.1 ¡À 16.5 (p <0.0001), LAD (cm) 38.8 ¡À 6.3 vs 35.2 ¡À 5.2 (p <0.0001); iLAV (ml/m2) 35 ¡À 16.2 x 21.9 ¡À 7 (p <0.0001), EF (%) 60.7 ¡À 16.2 vs 70.7 ¡À 6.9 (p <0.0001), E/e¡¯ 21 , 1 ¡À 8.1 vs 16.5 ¡À 2.4 (p <0.0001), HBP 81.8% vs. 50.2% (p <0.0001), DM 21.2% vs. 9.4% (p = 0.04); CHF 24.2% vs. 3.2% (p <0.0001), CAD 33.3% versus 9% (p <0.0001). Conclusion: Patients with elevated left ventricular filling pressures are older, have larger LA diameter and volume, worse EF and higher incidence of HBP, diabetes, CHF and CAD. There is less agreement between LAD and iLAV in these patients.


Subject(s)
Humans , Male , Female , Middle Aged , Echocardiography, Doppler/methods , Echocardiography , Atrial Fibrillation/complications , Atrial Function/physiology , Heart Atria
3.
J. epilepsy clin. neurophysiol ; 8(4): 211-216, Dez. 2002. tab
Article in English | LILACS | ID: lil-431940

ABSTRACT

As relações entre o padrão alternante cíclico e as epilepsias tem sido objeto de atenção nos últimos anos. Neste estudo analisamos o padrão alternante cíclico em grupos de pacientes com epilepsias idiopáticas, focais e generalizadas, comparando entre si dois grupos e ainda com um grupo-controle. Os resultados demonstraram redução do padrão alternante cíclico/padrão alternante não-cíclico apenas no grupo de pacientes com epilepsia generalizada idiopática. Concluímos que as epilepsias idiopáticas não afetam a microestrutura do sono ou suas relações com a macroestrutura do sono


Subject(s)
Epilepsies, Myoclonic , Epilepsy , Sleep
4.
Arq. neuropsiquiatr ; 60(2B): 353-357, June 2002. tab
Article in English | LILACS | ID: lil-310849

ABSTRACT

Sleep and epilepsy share some common mechanisms. The objective of the present investigation was to study the macrostructure of sleep in patients with idiopathic epilepsies, focal and generalized, comparing these two groups to each other and to a control group of 12 individuals without epilepsy. A total of 35 polysomnographies were performed, 12 of them in the control group, 10 in patients with idiopathic generalized epilepsies, and 13 in patients with idiopathic focal epilepsies. Antiepileptic medications were maintained for ethical reasons. The group with idiopathic focal epilepsy showed an increase in the total recording time (p = 0.04) and the group with idiopathic generalized epilepsy had a reduction of phase 4 NREM sleep. The efficiency of total sleep period and of total sleep time was also lower in the group with idiopathic generalized epilepsy (p = 0.03 in both cases). We concluded that the group with idiopathic generalized epilepsy presents sleep of poorer quality, whereas the group with idiopathic focal epilepsy presents a tendency toward an excessive somnolence


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Epilepsies, Partial , Epilepsy, Generalized , Sleep , Anticonvulsants , Epilepsies, Partial , Epilepsy, Generalized , Polysomnography , Sleep Stages
5.
Rev. bras. neurol ; 31(5): 215-7, set.-out. 1995. ilus
Article in Portuguese | LILACS | ID: lil-166861

ABSTRACT

Relatamos um caso de meningite pneumocócica em paciente adulto, etilista, que complicou com lesöes hipodensas multifocais da substância branca, de caráter necrótico com perda mielínica. Tais lesöes foram descritas raramente na literatura sendo que cinco dos oito casos previamente relatados foram causados pelo pneumococo. Såo comentados os aspetos anátomo-patológicos, bem como a possível fisiopatologia das lesöes da substância branca, que såo muito provavelmente de origem isquêmica, venosa, associada a uma flebiteretrógrada, com trombose das veias perfurantes. O tratamento em todos os casos descritos anteriormente foi com antibióticos, sendo a penicilina usada em todos os casos, associada ou nåo a outros antibióticos


Subject(s)
Humans , Male , Adult , Meningitis, Pneumococcal/complications , Meningitis, Pneumococcal/diagnosis , Streptococcus pneumoniae
SELECTION OF CITATIONS
SEARCH DETAIL