Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add filters








Language
Year range
1.
Chinese Journal of Schistosomiasis Control ; (6): 159-167, 2020.
Article in Chinese | WPRIM | ID: wpr-821627

ABSTRACT

Objective To characterize a species of the genus Tricula and parasitized trematodes in schistosomiasis-endemic areas of Yunnan Province using a molecular analysis, so as to understand their taxonomic positions. Methods Tricula spp. and Oncomelania snails were collected from Xiangyun County, Yunnan Province, and cercaria parasitizing snails were observed using crushing followed by microscopy. Cercaria parasitizing Tricula snails at various morphologies were sampled using a shedding method. Genomic DNA was extracted from snail soft tissues and cercariae, and the 16S rRNA, COI, 28S rDNA genes in snails and the ND1 and 28S rDNA genes in cercariae were amplified using a PCR assay and sequenced. The species of Tricula snails and their parasitized trematodes was characterized using sequence alignment and phylogenetic analysis. Results Among 382 Tricula snails detected, there were three types of trematode cercariae found, including the non-forked (20.94%, 80/382), double-forked (3.40%, 13/382) and swallow shapes (7.07%, 27/382). Sequence and phylogenetic analyses showed that the 16S rRNA, COI and 28S rDNA gene sequences of this species of Tricula had high homology to those in Delavaya dianchiensis, and were clustered in a branch. Sequencing analysis of the ND1 and 28S rDNA genes revealed that the non-forked cercariae belonged to the family Pleu- rogenidae, the swallow-shaped cercariae belonged to the family Opecoelidae, and the double-forked cercariae belonged to another species of the genus Schistosoma that was different from S. sinensium and S. ovuncatum. Conclusion The species and taxonomy of Triculla spp. and their parasitized trematodes are preliminarily determined in schistosomiasis-endemic areas of Yunnan Province; however, further studies are required to investigate the more definite taxonomy and pathogenicity.

2.
Chinese Journal of Ultrasonography ; (12): 480-483, 2013.
Article in Chinese | WPRIM | ID: wpr-434823

ABSTRACT

Objective To investigate the application of real-time three-dimensional transesophageal echocardiography (RT-3D TEE) in quantification of the aortic anuulus diameter in patients with severe aortic stenosis.Methods RT-3D TEE image of aortic root was get perioperatively in 65 patients with sever aortic valve stenosis during the surgery procedure.The aortic annulus was reconstructed in the quantitative analysis software to generate the parameters of 3-dimensional area based aortic anuulus diameter(3D-AAAD) and 3-dimensional circumference based aortic anuulus diameter(3D-C-AAD).The parameters was compared with intraoperative aortic anuulus diameter(IO-AAD),which was get by the standard cylindrical valve sizer.Results The three dimensional form of the aortic annulus was related to the number of the valves.The value of 3D-C AAD and 3D-A-AAD were (22.4 ± 2.1) mm,(23.4 ± 1.9) mm,no significant difference could be detected between them and the IO-AAD (P < 0.05).The 3D-C-AAD had a better agreements with IO-AAD than 3D-A-AAD.Conclusions RT-3D TEE can reconstruct the three dimensional sharp of aortic anuulus,and can be used as quantitative tools to calculate its diameter.

3.
Chinese Journal of Ultrasonography ; (12): 829-832, 2012.
Article in Chinese | WPRIM | ID: wpr-423610

ABSTRACT

Objective To study the the feasibility of real-time 3D transesophageal echocardiography (RT-3D TEE) to measure the distance between the coronary ostial and the junction of left ventricle and artery.Methods The RT-3D TEE image of the aortic root was collected intraoperative in 65 cases who were refered to our center for valve replacement.The reconstruction of the aortic annulus was done in the QLAB quantitative analysis software and the height parameter of the annulus could be generated.Meanwhile the coronary artery position was observed and the distance between the coronary ostial and the junction of left ventricle and artery was measured respectively.Results In the 65 cases,49 cases clearly showed bilateral coronary ostial,three cases only showed the left coronary ostial,six cases only showed the right coronary ostial,seven cases of both sides of the coronary ostial were unclear.The shows rate of right coronary ostial was 84.61% (55/65),with the left coronary ostial 81.54% (52/65).The measured value of the L-AA in systole and diastole were (15.5 ± 1.9)mm,(12.8 ± 1.5)mm,the R-AA systole and diastole measured values were (13.7 ± 1.8)mm,(12.4 ± 1.7)mm,respectively,there was significant difference between systole and diastole respectively.The aortic annulus height (H) got by 3D reconstruction of the aortic annulus was lower than ventricular-arterial junction to the coronary artery distance in both systole and diastole.Conclusions Not only can RT-3D TEE reconstruct the annulus,but also can show and measure the distance between the coronary ostial and the junction of left ventricle and artery respectively.

4.
Chinese Journal of Ultrasonography ; (12): 471-474, 2011.
Article in Chinese | WPRIM | ID: wpr-415475

ABSTRACT

Objective To evaluate the usefulness of real-time three-dimensional transesophageal echocardiography (RT-3D TEE) in the perventricular device occlusion of the ventricular septal defect (VSD).Methods Sixty patients underwent perventricular device occlusion of VSD were divided into two groups.Group A:30 patients,3D images of VSD were obtained intraoperatively by RT-3D TEE.3D images were analyzed and the maximal and minimum area and maximal diameter of VSD were measured in the cardiac cycle.The size of selected VSD occluder was the diameter calculated from the maximal area based on the formula πD2/4 and plus 1~2 mm.Simultaneously,two dimensional transesophageal echocardiography (2D TEE) images of VSD were obtained and measured on standard views.Group B:other 30 patients,intraoperative 2D TEE was performed to measure the diameter of VSD on standard views.The selection VSD occluder was based on the maximal diameter plus 1~2 mm.Results The VSDs shape showed oval,class round and irregular by RT-3D TEE imaging.There was a significant difference between the maximal area and smallest area of VSD appeared in the cardiac cycle obtained by RT-3D TEE (P<0.01).There was a significant difference between the maximal diameter by measurement of RT-3D TEE and 2D TEE (P<0.01).Of all 30 patients with evaluation of VSD size based on the RT-3D TEE,1.1 times attempts of device occlusion were performed on one patient (33/30).Of the other 30 cases with evaluation of VSD size by 2D TEE,2 cases were failed with device occlusion because of instant residual shunt.Of the remaining 28 cases,1.43 attempts of device occlusion were performed on one patient (40/28).Conclusions RT-3D TEE can accurately reveal the size of VSD,and aid in the selection of VSD occluder in the device occluding procedure of VSD.

SELECTION OF CITATIONS
SEARCH DETAIL