Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
Add filters








Year range
1.
Chinese Journal of Radiological Medicine and Protection ; (12): 343-350, 2023.
Article in Chinese | WPRIM | ID: wpr-993095

ABSTRACT

Objective:To investigate the necessity and feasibility of the virtual simulation teaching experiment software of the bronchoscopy intelligent navigation-based fiducial marker implantation technology in the clinical application of radiotherapy.Methods:This study developed a 3D virtual operation and interactive system using the Unity3D engine, tools including 3Dmax and Maya, and the SQL database. The scenes in the system were produced using the currently popular next-generation production process. Targeting the priorities and difficulties in the implantation of fiducial markers, the system developed in this study allowed for simulated demonstration and training based on 12 steps and 10 knowledge points. Internal tests and remote evaluation tests were adopted in this system to obtain the test result of each subject. Then, the application value of the system was analyzed based on the test result.Results:As of May 1, 2022, the system had received 2 409 views and 425 test participants, with an test completion rate of 100% and an experiment pass rate of 96.5%. Moreover, this system won unanimous praise from 167 users, primarily including the students majoring in multilevel medical imaging technology and medical imaging science from the Fujian Medical University, as well as the radiotherapy-related staff of this university.Conclusions:The virtual simulation teaching experiment software of the bronchoscopy intelligent navigation-based fiducial marker implantation technology can be applied to the teaching of students and the training of related professionals.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 81-86, 2023.
Article in Chinese | WPRIM | ID: wpr-993055

ABSTRACT

Objective:To evaluate the feasibility of a novel liver fiducial marker implantation method for internal fixation and removal of rabbit livers, in order to use in Cyberknife tracking therapy.Methods:Experiments were conducted in vivo and in vitro. In the in vivo experiment, three fiducial markers were implanted percutaneously in each liver of ten rabbits under anesthesia, and the fourth fiducial marker with an external catheter and fixed thin wire was implanted ten days later. After the reference group (the first and the second maker), and the casing group (the first and the fourth marker) were respectively registered and tracked with the Cyberknife, the implantation success rate, registration accuracy, and removal safety of fiducial markers were assessed. The tensile test was performed using liver in vitro by measuring the resistance required to dislodge the spring coil fiducial markers and the fiducial markers without spring coil from liver. Results:The intrahepatic catheter implantation and removal of fiducial marker in rabbit liver had a success rate of 100% and no distant migration. The operation-related and postoperative complications were not occurred. All fiducial markers were successfully traced. Compared to the reference group, the casing group had slightly higher translational errors in supero-inferior and antero-posterior directions ( Z=-11.77, -4.57, P<0.05), and lower translational errors in left-right direction ( Z=-2.52, P<0.05). The dislodgement forces for spring coil fiducial markers was (2.23±0.85) N, significantly different with (0.81±0.13) N for fiducial markers without spring coil ( Z=- 2.31, P < 0.05). Conclusions:The spiral coil structure provides superior fixation in the punctured needle channel, the thin line limits the distant displacement of the fiducial marker outside the liver, and the catheter establishes a channel for the removal. The general operation is simple and easy.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 8-14, 2023.
Article in Chinese | WPRIM | ID: wpr-993044

ABSTRACT

Objective:To investigate the effects of down-regulation of FABP5 (fatty acid binding protein 5) on radiation damage of skin cells, and explore underlying mechanism.Methods:A lentiviral vector with down-regulated FABP5 was constructed to infect human immortalized keratinocytes (HaCaT) cells, and the transfection efficiency was examined. The HaCaT cells were divided into blank control group, FABP5 down-regulation group (FABP5), radiation group (IR), and FABP5 down-regulation combined with radiation group (FABP5+ IR). After 6 MV X-ray radiation, cell proliferation viability was measured by CCK-8 assay, cell migration was detected by scratch assay, apoptosis was analyzed by flow cytometry, radiosensitivity was evaluated by cloning formation assay, and the cellular protein expressions of PARP1, γ-H2AX, AKT and p-AKT were detected by Western blot.Results:FABP5 was successfully knocked-down in both RNA level ( t=25.14, P<0.05) and protein level ( t=20.06, P<0.05). The down-regulation of FABP5 decreased the abilities of cells proliferation ( t=3.55, 5.88, 3.18, P<0.05) and migration ( t=15.44, P<0.05), but increased cell resistance to irradiation with a radiosensitization ratio of 0.782. The apoptosis rate of FABP5+ IR group was significantly lower than IR group (22.05±6.71)% vs. (9.82±1.45)%, t=3.08, P<0.05. The protein levels of PARP1 and γ-H2AX in FABP5+ IR group were also lower than those in the IR group 0.04±0.04, 0.11±0.06, 0.26±0.11, 0.22±0.07, 0.21±0.10, 0.52±0.22, 0.57±0.06, 0.43±0.02( t=2.83, 3.07, 4.50, 5.33, P<0.05), while the protein level of p-Akt in FABP5+ IR group was higher than that in IR group ( t=-16.24—3.02, P<0.05). Conclusions:Down-regulation of FABP5 inhibited cell proliferation and migration, increased radioresistance, and reduced radiation-induced apoptosis and DNA damage of skin cells probably through PI3K/AKT signaling pathway.

4.
Chinese Journal of Radiation Oncology ; (6): 313-318, 2023.
Article in Chinese | WPRIM | ID: wpr-993193

ABSTRACT

Objective:To analyze the diagnostic and prognostic value of routine bone marrow examination in patients with extranodal NK/T-cell lymphoma (ENKTCL) based on PET-CT staging.Methods:Clinical data of 186 patients who received bone marrow biopsy and bone marrow aspiration in Fujian Medical University Union Hospital from 2013 to 2021 were retrospectively analyzed. All patients were divided into bone marrow biopsy + bone marrow aspiration group ( n=186) and PET-CT + bone marrow biopsy group ( n=139). The sensitivity, specificity, positive and negative predictive values were compared between two groups. The data were analyzed and plotted. Survival analysis was performed using Kaplan-Meier method and log-rank test. Results:In the whole cohort, 45 patients were positive for bone marrow biopsy, and 30 of them were positive for bone marrow aspiration. A total of 141 patients who were negative for bone marrow biopsy also achieved negative results for bone marrow aspiration. A total of 139 patients completed PET-CT staging and bone marrow biopsy. And 30 patients were diagnosed with positive bone marrow by PET-CT, in which 22 of them were confirmed positive by bone marrow biopsy. Among 109 patients diagnosed with negative bone marrow by PET-CT, 5 of them were confirmed positive by bone marrow biopsy. All these cases were classified as stage Ⅳ due to distant metastases. PET-CT had a diagnostic sensitivity of 81.5%, a specificity of 92.9%, a positive predictive value of 73.3%, and a negative predictive value of 95.4%. Among early stage (Ⅰ-Ⅱ stage) patients diagnosed with PET-CT, all of them were negative for bone marrow biopsy (the negative predictive value was 100%). In stage Ⅳ patients ( n=55), the 1-year overall survival of patients with bone marrow involvement by bone marrow biopsy or PET-CT ( n=35) compared with their counterparts with the involvement of other organs ( n=20) was 28.7% vs.42.0% ( P=0.13), and 1-year progression free survival rates was 23.2% vs. 23.3% in ( P=0.94). Conclusions:Routine bone marrow biopsy does not change the original staging of patients with early stage ENKTCL based on PET-CT staging. Advanced stage patients with positive bone marrow biopsy tend to obtain worse prognosis, indicating that bone marrow biopsy still has certain value.

5.
Organ Transplantation ; (6): 435-2023.
Article in Chinese | WPRIM | ID: wpr-972935

ABSTRACT

Objective To evaluate the policy of human organ transplantation in China, aiming to provide theoretical basis for further optimizing the policy of human organ transplantation. Methods Based on text mining and statistical analysis, seven normative policies of human organ transplantation formulated by national government from 2000 to 2022 were quantitatively evaluated by constructing policy modeling consistency (PMC) with 10 first-level variables and 35 second-level variables. Results Among the seven policies, six were graded as excellent policies and one as perfect policy, with an average PMC index of 8.476. Except X8 policy audience, the scores of other second-level variables of P5 were higher than or equal to the mean. The scores of all second-level variables of P1 were lower than or equal to the mean. P1 and P5 significantly differed in X3 policy timeliness, X4 policy norms and X6 policy tools. P5 was more specific and relatively comprehensive in these aspects, and its score was significantly higher than that of P1. Conclusions Human organ transplantation policies in China are generally excellent, scientific and rational. Health administrative departments at all levels should pay attention to the grasp of policy timeliness, the combination of policy tools, and fully mobilize the initiative and enthusiasm of all policy audience to participate in organ transplantation management when formulating organ transplantation policies.

6.
Chinese Journal of Radiological Medicine and Protection ; (12): 865-870, 2022.
Article in Chinese | WPRIM | ID: wpr-956873

ABSTRACT

Objective:To explore the feasibility of recoverable fiducial marker implantation guided using the intelligent navigation bronchoscopy technology in the Cyberknife Synchrony-based respiratory tracking.Methods:CT scans of an inflatable pig lung after anti-rot processing were obtained. Then, eight simulated tumor lesion sites were designed in the left and right lung lobes using intelligent navigation software, with four classified as the sputum bronchial environment group and four classified as the wet bronchial environment group. Based on the implantation principle of Cyberknife fiducial markers, 32 recoverable fiducial markers were implanted around various simulated tumor lesions via bronchus under intelligent guidance. Then, the end-expiratory state of the pig lung was simulated, the pig lung was scanned again to obtain CT images of the implanted recoverable fiducial markers, and the number of successfully implanted fiducial markers was recorded. Eight deliverable Synchrony treatment protocols were designed using the Cyberknife planning system (Multiplan v4.6), and then the pig lung with simulated respiratory movements was exposed to radiation. After radiation, the implanted recoverable fiducial markers were retrieved using the bronchoscopy technique, and the number of successfully retrieved fiducial markers was recorded. Moreover, the translational errors, rotational errors, and rigid body errors were extracted from the Cyberknife log file and analyzed.Results:No recoverable fiducial markers slipped or fell during the experiment. Thirty-two recoverable fiducial markers were successfully implanted and recovered under the guidance of intelligent navigation bronchoscopy, with implantation and recovery success rates of both 100%. Moreover, the tracking rate and rigid body errors of the fiducial markers were 100% and less than 5 mm, respectively. The data from the Cyberknife log file indicated that there was no significant difference between the sputum bronchial environment group and the wet bronchial environment group in the translational errors in the left-right direction, the rotational errors in the roll direction, and the rotational errors in the pitch direction ( P>0.05). Compared to the wet bronchial environment group, the sputum bronchial environment group had slightly higher translational errors in front-back ( Z=-3.57, P<0.01) and cranio-caudal ( Z=-2.53, P<0.05) directions, lower rotational errors along the yaw axis ( Z = -3.88, P < 0.01), and lower rigid body error ( Z=-3.32, P<0.01), and the differences were all statistically significant. Conclusions:The recoverable fiducial marker implantation guided using the intelligent navigation bronchoscopy technology is feasible. Recoverable fiducial markers are stable in the bronchus of the phantom, and the Cyberknife tracking precision can meet clinical requirements. Therefore, the recoverable fiducial marker implantation guided using the intelligent navigation bronchoscopy technology has promising prospects in clinical and teaching applications.

7.
Chinese Journal of Radiation Oncology ; (6): 47-53, 2021.
Article in Chinese | WPRIM | ID: wpr-884514

ABSTRACT

Objective:To analyze the predictive effect of tumor deposit(TD) on the prognosis of yp-stage Ⅲ rectal cancer patients, and its effect on postoperative adjuvant chemotherapy benefit.Methods:Clinical data of 338 ypⅢ stage rectal cancer patients who received multidisciplinary treatment in Union Medical College Affiliated Hospital of Fujian Medical University from 2007 to 2017 were retrospectively analyzed. All patients were divided into the TD(-) group( n=301) and TD(+ ) group( n=37). Survival analysis was conducted by Kaplan- Meier method, log-rank test and univariate prognostic analysis. Multivariate prognostic analysis was performed by Cox’s regression model. Results:The 5-year overall survival(OS), progress-free survival(PFS), and distant metastasis-free survival(DMFS) in the TD(-) group were significantly higher than those in the TD(+ ) group(59.3% vs. 42.0%, P=0.001, 79.1% vs. 55.0%, P<0.001, 55.6% vs. 38.0%, P<0.001), whereas no significant difference was observed in local recurrence-free survival(LRFS) between two groups(96.7% vs. 85.5%, P=0.679). Univariate prognostic analysis revealed that the number of TD was not correlated with the prognosis of patients( P=0.923), and postoperative adjuvant chemotherapy exerted no significant effect on the prognosis of patients in two groups( P=0.103). In multivariate analysis, TD was associated with worse OS( HR=2.343, 95% CI: 1.257-4.363, P=0.007). Conclusions:For patients with ypⅢ stage rectal cancer undergoing multidisciplinary treatment, the prognosis of patients with TD is even worse. TD is an independent predictor for survival. No benefit can be obtained from postoperative adjuvant chemotherapy regardless of the presence or absence of TD.

8.
Chinese Journal of Radiation Oncology ; (6): 1059-1064, 2021.
Article in Chinese | WPRIM | ID: wpr-910514

ABSTRACT

Objective:To explore the application value of skin lead marker combined with iSCOUT image-guided positioning system in monitoring and correcting the setup error of intensity-modulated radiotherapy (IMRT) for breast cancer and calculate the PTV margin, aiming to provide reference for clinical practice.Methods:25 breast cancer patients treated with IMRT after modified radical mastectomy in Fujian Medical University Union Hospital from April to August 2019 were enrolled in this study. The skin lead marker combined with iSCOUT image-guided positioning system was employed for image-guided positioning based on the gold standard registration algorithm. Initial setup errors on the x (lateral), y (craniocaudal) and z (anteroposterior) axis and residual errors after the position correction were recorded and analyzed. The effect of the errors before and after image-guided correction upon the plan dose was compared and the reasonable PTV margin was calculated.Results:25 patients received 150 times of positioning verification using skin lead marker combined with iSCOUT image-guided positioning system. The absolute residual errors on the x-, y-and z-axis were (1.53±0.96), (1.30±0.99) and (1.34±0.92) mm, significantly smaller than the initial setup errors of (2.63±2.12), (2.41±2.45) and (3.07±2.77) mm (all P<0.001). The percentage of dose deviation due to residual errors was also smaller than that of the initial errors. Significant differences were observed in D 98%, D 2%, D max of PTV, D max of the heart, D max of the healthy breast, and D mean of the affected lung and both lungs. The percentage deviation from the original plan was decreased from 2.18%, 3.19%, 10.66%, 8.75%, 48.21%, 10.50%, and 3.66% to 0.38%, 0.23%, 2.31%, 0.04%, 13.78%, 6.35% and 0.41%, respectively (all P<0.05). PTV margins on the x-, y-and z-axis after correction were calculated as 1.87, 1.75 and 1.69 mm, respectively. Conclusion:It is feasible and valuable to apply the skin lead marker combined with iSCOUT image-guided positioning system in the positioning verification and correction of breast cancer radiotherapy position, providing novel reference for clinical PTV margin.

9.
Chinese Journal of Radiation Oncology ; (6): 1070-1074, 2020.
Article in Chinese | WPRIM | ID: wpr-868730

ABSTRACT

Objective:To develop a remote training system for CT simulation positioning of radiotherapy using virtual reality technology, and to explore a new method of medical training.Methods:The 3DMax and Maya were employed to establish the 3D model. The unity3D engine was adopted to develop 3D virtual operation and interaction system. Java spring MVC architecture was utilized as the system background service. MySQL was used as the background database system. The users were assigned into two roles: teacher and student, and the modes were divided into teaching and assessment modes.Results:The function of the system covered the whole process of CT simulation positioning, mainly including modules of patient information management, CT simulation positioning machine cognition, body position fixation technology, CT positioning scanning, and emergency handling, etc. Since it was put into use in 2018, the system has been running stably, with 14 920 pages views and an 86.66% pass rate. Compared with the traditional training, the training efficiency has been significantly improved and has received unanimous recognition.Conclusions:The remote training system can effectively improve the clinical practice ability and humanistic care ability of the trainees, which has good autonomy, sharing, and innovation. At present, the system has been put online and has strong popularization with prospects for broad application.

10.
Chinese Journal of Radiation Oncology ; (6): 300-303, 2020.
Article in Chinese | WPRIM | ID: wpr-868598

ABSTRACT

Objective:To design and implement a network-based quality management system for tumor radiotherapy.Methods:The system consists of B/S framework-based three-layer structures including the application layer, system service layer and data layer. It utilizes Nutz as the development framework to develop web applications, MySQL as the system database, Java programming language for system development, Tomcat as a system application server for project release and IE, Google and other mainstream browsers to achieve client access server functions.Results:The system can support integrated information management and service of quality control institutions at the provincial, municipal and county levels. The functions include procedure management, case management, quality control management, notification announcement, data management and system management, etc. The system has been set up and tested in the cooperation units, and the operation and function are in good condition.Conclusion:The system can support the assessment of online quality control, which is conducive to information analysis and sharing, promotes the standardization and normalization of quality control and improves work efficiency. Case management function can monitor the diagnosis and treatment processes of patients, establish continuous electronic record, deliver rational treatment and rehabilitation guidance plan, which play a pivotal role in the evaluation of tumor radiotherapy.

11.
Chinese Journal of Radiation Oncology ; (6): 394-397, 2019.
Article in Chinese | WPRIM | ID: wpr-745319

ABSTRACT

Neoadjuvant chemoradiotherapy followed by TME is a common treatment at present for locally advanced rectal cancer.Several studies abroad in recent years have shown that statins have a positive effect on cancer resistance.We discussed the mechanism and clinical application of statins in preoperative neoadjuvant chemoradiotherapy of locally advanced rectal cancer.

12.
Chinese Journal of Radiation Oncology ; (6): 1093-1096, 2018.
Article in Chinese | WPRIM | ID: wpr-708328

ABSTRACT

Objective To discuss the necessity and feasibility of application of virtual reality (VR) technology in the teaching course of radiotherapy technology based on the contradictions between the theory and practice of current teaching mode.Methods After in-depth analysis of the characteristics of the existing disciplinary teaching mode,VR technology was introduced to design software,glasses,operating handles and establish a special interactive platform. The teaching courses could be delivered via mobile phone side AR, helmet and AR, touch screen and PC virtual simulation with VR virtual simulation, etc. Six processes of radiotherapy were tested through online courses and offline groups to analyze the feasibility of this technology applied in the training of radiotherapy professionals. Results After the design of software and hardware and the analysis of test results,the online teaching could be utilized to write interactive programs,build virtual experience scenes, create course resource database and construct practical training courses and teaching system. The offline practice test could be applied to the simulation learning of feedback of the whole process, which possessed feasibility and development value. It could be applied to the theory and practice teaching of radiation therapy technology,making the teaching more convenient,vivid and intuitive. Conclusions VR technique combined with radiotherapy technology training can be delivered through online and offline teaching courses of theory and practice by using the plane and virtual simulation technology, which is convenient, quick and highly efficient and deserves widespread application.

13.
Chinese Journal of Radiation Oncology ; (6): 624-628, 2018.
Article in Chinese | WPRIM | ID: wpr-708249

ABSTRACT

High dose grid radiotherapy ( GRID ) refers to a single fraction of high-dose radiation ( 10-25 Gy) in which, beams are divided into multiple small beam lets through a grid collimator or MLC, resulting in non-uniform dose distribution of high and low dose area ("peak-to-valley" effect) in the target volume. Recently, as 3D radiotherapy ( 3DRT) technology emerged, the 2D GRID has been reconfigured into 3D dose LATTICE whereby high doses are concentrated at each lattice vertex within the radiation target volume with drastically lower dose between vertices through multiple focused non-coplanar beams with different radiation techniques. Compared with 2D GRID therapy, 3D LATTICE shows significant effect on"peak-to-valley" and minimizes radiation to surrounding tissues. Experimental and clinical data have shown that LATTICE therapies can reduce toxicity to normal tissue while stimulating bystander effects, endothelial cell death and immunogenic abscopal effects leading to enhanced killing of tumor cells and further improve the control of the local and distant disease. The clinic experience with LATTICE, although limited, has demonstrated favorable outcomes, especially for treating bulky tumors and palliative intend. The exact mechanism of the clinical advantages by LATTICE is not explicitly known and a more comprehensive biological study and clinical trials are called should be carried out.

14.
Chinese Journal of Radiological Medicine and Protection ; (12): 424-428, 2018.
Article in Chinese | WPRIM | ID: wpr-708081

ABSTRACT

Objective To analyze the effect of the new conformal index(nCI)and the conventional conformal index(CI)on the treament planning quality of lung stereotopic radiotherapy(SBRT).Methods A total of 19 peripheral lung cancer patients,treated with SBRT in Fujian Medical University Union Hospital from 2014 to 2017,were analyzed retrospectively.Each patient was planned twice yielding identical CI and nCI.The prescription to 95%of planning target volume(PTV)was 48 Gy in four fractions,and renormalization was performed when needed for nineteen nCI plans.The Wilcoxon signed-rank test was used to examine the dosimetric index.Results The dose conformity plots indicate that nCI does not only reflect the dose to the organ at risk outside tumor,but also represents the dose distribution in the PTV.In addition,nCI was stricter with treatment planning qualities when the dose around PTV was closer to the prescribed dose.The value of target coverage(TC),the ratio of out-of-target volumes receiving 105%prescribed dose to the target volume(R105%),the ratio of volume covered by 50%isodose line to the target volume(R50%),and the ipsilateral lung V20were 98.70%,0.56,5.53,15.59%in the CI plans,vs.90%,0,4.99,14.42%in the corresponding nCI plans,respectively.All index were significantly lower in the nCI group(Z =-3.823,-3.180,-3.823,-3.783,respectively,P<0.05).The ratio of the maximum dose to the 2 cm external margin from the PTV(D2 cm)to the maximum dose to the PTV were 63.70%and 64.07%respectively in the two groups,and the differences were not statistially significant(P>0.05).The conformity values denoted a clinically favorable value as 1 between D95%and D99%of nCI plans,yet were not applicable to CI plans.Conclusions It is more clinically relavant to evaluate lung SBRT plans using nCI,TC and other indicators collectively than using CI alone.

15.
Chinese Journal of Radiological Medicine and Protection ; (12): 628-631, 2015.
Article in Chinese | WPRIM | ID: wpr-481007

ABSTRACT

Objective To investigate the dosimetric performance of two algorithms for correcting the presence of tissue inhomogeneities,the finite site pencil beam (FSPB) and X-ray voxel Monte Carlo (XVMC) plans were implemented in the MONACO system,with the accuracy of application to clinic treatment of two algorithms were evaluated.Methods In a non-uniform artificial anthropomorphic phantom,regular open fields and intensity modulation radiated therapy (IMRT) plans of the MONACO were measured by using calibrated EBT2 films,and the dose accuracy of the two kinds of plans was analyzed by comparing the planned and measured plane dose.Results In an anthropomorphic phantom,the deviations between the calculated values by XVMC and the measured values by films were less than ± 2%.While the deviations of FSPB values between calculation and measurements was within ± 3%,except at the condition of 15 MV,10 cm ×2 cm field,the dose error in lung was up to 6.51%.The verification of individual IMRT beams based on films showed that the pass rates of calculation by XVMC and FSPB were larger than 90% with γ criterion of 3%/3 mm and 4%/4 mm,respectively.At 3%/3 mm,the pass rates of FSPB were in the range of 80%-90%.At the same time,the pass rates of all individual fields were higher than 90%.Conclusions The accuracy of dose calculation of XVMC is better than that of FSPB when being in multi-segments and non-uniform media.The error of algorithm can be controlled within ±3%,for the calculation by XVMC.And the dose deficiency of PTV arising from algorithm can be avoided.

16.
Chinese Journal of Radiation Oncology ; (6): 627-632, 2015.
Article in Chinese | WPRIM | ID: wpr-480474

ABSTRACT

Objective To evaluate the potential influencing factors associated with pathologic complete response ( pCR) after neoadjuvant chemoradiotherapy for locally advanced rectal cancer ( LARC) . Methods A retrospective analysis was performed on the clinical data 265 patients with stageⅡandⅢ( the 7th version of AJCC) rectal cancer admitted to our hospital from 2011 to 2013. All patients underwent neoadjuvant concurrent chemoradiotherapy ( CCRT ) followed by surgery with/or without induction chemotherapy during the interval between the complete of CCRT and surgery. The predictors associated with pCR were analyzed by univariate and multivariate logistic regression analyses. With the use of the independent predictive variables for pCR from multivariate analysis, a clinical risk score model was established according to the following criteria:no?risk group (0 factor);low?risk group (1 factor);high?risk group ( 2 factors) . Results Among these 265 patients, 50( 18. 9%) achieved pCR. The univariate analysis showed that carcinoembryonic antigen ( CEA) level before CCRT ( P=0. 017) , T stage before CCRT ( P=0. 001), interval between complete of CCRT and surgery (P=0. 000), and the maximum tumor thickness before CCRT ( P=0. 040) were significantly associated with pCR. The multivariate analysis showed that pre?CCRT CEA level ( P=0. 021 or 0. 446) and interval between the complete of CCRT and surgery ( P=0. 000 or 3. 774) were significant predictors of pCR. When stratifying for smoking status, only low pre?CCRT CEA level was significantly associated with pCR in the non?smoking patients ( P=0. 044) . For the prediction of pCR by the clinical risk score model, the sensitivity was 0. 805, the specificity was 0. 460, the area under the receiver operating curve was 0. 690 ( 95% CI= 0. 613?0. 767 ) , the positive predictive value was 35 . 4 9%, the negative predictive value was 8 6 . 5%, and the predictive accuracy was 7 3 . 9%. Conclusions For locally advanced rectal cancer, pCR can be achieved in some patients after neoadjuvant therapy. Low pre?CCRT CEA level and long interval time between CCRT and surgery are independent factors associated with pCR, and only low pre?CCRT CEA level is an associated factor in the group of nonsmokers. The clinical risk score model based on pre?CCRT CEA level>5 ng/ml and time interval from CCRT completion to surgery≤8 weeks can be used to predict pCR after neoadjuvant chemoradiotherapy for LARC.

17.
Chinese Journal of Gastrointestinal Surgery ; (12): 556-560, 2014.
Article in Chinese | WPRIM | ID: wpr-239359

ABSTRACT

<p><b>OBJECTIVE</b>To explore predictive factors associated with pathologic complete response (pCR) after neoadjuvant chemoradiotherapy for rectal cancer.</p><p><b>METHODS</b>Clinicopathological data of 163 patients with locally advanced rectal cancer who were treated with neoadjuvant chemoradiotherapy followed by radical surgical resection from January 2007 to May 2013 were analyzed retrospectively. Univariate analysis and multivariate logistic regression analysis were performed to analyze associated factors of pCR, including age, gender, body mass index (BMI), diabetes, anemia, tumor diameter, distance of the tumor from the anal verge, circumferential extent of the tumor, tumor pathological types, tumor differentiation, pre-chemoradiotherapy T stage, pre-chemoradiotherapy N stage, pre-chemoradiotherapy CEA level, pre-chemoradiotherapy CA199 level, per-operation CEA level, pre-operation CA199 level, radiation dose, chemotherapy modality, time interval from completion of chemoradiotherapy to surgery, etc.</p><p><b>RESULTS</b>Twenty-nine patients(17.8%) achieved pCR after neoadjuvant chemoradiotherapy for rectal cancer. Univariate analysis showed circumferential extent of tumor(≥1/2 cycle)(P=0.018), tumor pathological types(adenocarcinoma)(P=0.036), tumor differentiation (moderate or high)(P=0.021) and pre-chemoradiotherapy CEA level(≤2.5 μg/L)(P=0.007) were significantly correlated with pCR after neoadjuvant chemoradiotherapy for rectal cancer. Logistic regression revealed that circumferential extent of tumor (≥1/2 cycle)(OR=2.901, P=0.020) and pre-chemoradiotherapy CEA level (≤2.5 μg/L)(OR=2.775, P=0.022) were independent predictive factors of pCR after neoadjuvant chemoradiotherapy for rectal cancer.</p><p><b>CONCLUSION</b>Patients with circumferential extent of tumor ≤1/2 and pre-chemoradiotherapy CEA level ≤2.5 μg/L are more likely to achieve pCR after neoadjuvant chemoradiotherapy for rectal cancer, and these two indices can be used to predict pCR after neoadjuvant chemoradiotherapy for rectal cancer.</p>


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Chemoradiotherapy , Neoadjuvant Therapy , Rectal Neoplasms , Therapeutics , Retrospective Studies , Treatment Outcome
18.
Chinese Journal of Endocrinology and Metabolism ; (12): 553-556, 2013.
Article in Chinese | WPRIM | ID: wpr-437697

ABSTRACT

Objective To investigate the discriminant analysis model of gray-scale ultrasound (GSUS),contrast-enhanced ultrasound (CEUS) and the combination of them in the differential diagnosis of benign and malignant thyroid lesions and the diagnostic values.Methods Ultrasound images of 211 thyroid lesions confirmed by pathology were synthetically reviewed by scoring 5 GSUS indicators including shape (X1),orientation (X2),interior echogenicity (X3),halo sign (X4),and microcalcification (X5),as well as 6 CEUS indicators including relative arrival time of microbubhles in the periphery (X6) and interior (X7),peak periphery (X8) and interior (X9)echogenicity,peripheral ring-enhancement (X10),homogeneity of enhancement (X11).The diagnostic models with their values of GSUS,CEUS and the combination of them were explored by discriminant analysis.Results The discriminant analysis function of GSUS in the diagnosis of thyroid benign and malignant lesions was g1 (X) =0.715 X1+0.276X2 + 1.028X3 +1.197X4 +0.923X5-2.202 with the diagnostic value 86.3%,the discriminant analysis function of CEUS was g2(X) =-0.392X6 +0.541X7-0.117X8 +0.562X9 + 1.173X10 +2.200X11-1.956 with the diagnostic value 89.1%,and the discriminant analysis function of the combination of GSUS and CEUS was g3 (X) =0.418X1 + 0.173X2 + 0.626X3 + 0.558X4 + 0.183X5-0.476X6 + 0.474X7-0.071X8 + 0.399X9 + 0.985X10 +1.639X11-2.530 with the diagnostic value 91.0%.Conclusions GSUS and CEUS were valuable in the differential diagnosis of benign and malignant thyroid lesions,and the combination of GSUS and CEUS was most valuable.

19.
Chinese Journal of Ultrasonography ; (12): 317-320, 2013.
Article in Chinese | WPRIM | ID: wpr-434802

ABSTRACT

Objective To extract principal components from valuable indicators on conventional ultrasoundand contrast-enhanced ultrasound (CEUS) in the differential diagnosis of thyroid benign and malignant lesions and to discuss the diagnostic value of each indicator.Methods One hundred and three patients with 125 thyroid lesions (65 malignant lesions and 60 benign lesions) underwent preoperative grayscale ultrasound (GSUS),color Doppler ultrasound (CDUS) and CEUS examinations.Eighteen indicators were chosen to evaluate every lesion and principal components were extracted by principal component and valuable indicators were ordered by importance.Results There were significant differences on GSUS and CEUS indicators between benign and malignant lesions.The first principal component was the representation of contrast enhanced ultrasound and was valuable in the differential diagnosis of thyroid benign and malignant lesions.The rank of valuable CEUS indicators were homogeneity of enhancement,filling defect,relative arrival time of periphery,peak interior echogenicity,relative arrival time of interior,peak peripheral echogenicity and ring enhancement.Conclusions GSUS and CEUS are valuable in the differential diagnosis of thyroid benign and malignant lesions.

20.
Chinese Journal of Ultrasonography ; (12): 408-410, 2010.
Article in Chinese | WPRIM | ID: wpr-389600

ABSTRACT

Objective To evaluate the value of quantitative analysis of real-time elastosonography in the differential diagnosis of benign and malignant thyroid nodules. Methods The elastograms of eight-six patients with 98 thyroid nodules were observed. The strain ratio of each lesion and the averages of those of benignancy and malignancy were calculated. With the ROC curve, the critical point of the strain ratio of different lesions was gotten. All the lesions were confirmed with surgery and pathologic examination. Results The average of strain ratio of benign nodules was 2. 18,while that of malignancy was 8. 48. The strain ratio of benign and malignant lesions were of significant difference statistically (P <0.05). According to ROC curve, the critical point of strain ratio between benign and malignant lesions was 3. 3. Conclusions The quantitative analysis of real-time elastosonography is a newly valuable technique of ultrasonography which is helpful in the differential diagnosis of thyroid lesions.

SELECTION OF CITATIONS
SEARCH DETAIL