Results 1 - 20 de 109
Filter
1.
Arq. bras. oftalmol ; 84(3): 304-305, May-June 2021.
Article in English | LILACS-Express | LILACS | ID: biblio-1248959
3.
Arq. bras. oftalmol ; 77(5): 275-279, Sep-Oct/2014. tab, graf
Article in English | LILACS | ID: lil-730373

ABSTRACT

The practical advantages of quantifying an angle by a ratio of linear lengths instead of arcs of circles has led to the definition of the prism-diopter, a conventional unity for numbering prisms and measuring strabismic deviations. However, a major inconvenience of using prism-diopter unities to express angular measurements is the non-linearity of the scale, which reaches an infinite value for the angle of 90º, then becomes negative, with decreasing magnitudes for increasing angles between 90º and 180º. As a consequence, arithmetical operations and comparisons of angles measured by such unities present errors of very great magnitudes. In order to retain the advantages of defining an angle by straight line dimensions but to diminish the severe inconveniences of this method, a new definition of the prism-diopter is proposed. Here, instead of defining the prism-diopter by the asymmetrical condition, the conception of this new unity is based on a geometrically symmetrical condition; that of the relationship of an isosceles triangle (where the leg is perpendicular to the bisector of the angle and the bisector itself ). The condition of symmetry for the definition of the new unity represents a conceptual advance because it reproduces the already well accepted, conventional criteria for quantifying the value of a prism, that of its minimum deviation. Furthermore, it corresponds to the most commonly observed clinical conditions of binocular balance. The absolute differences between the unitary values of the prism-diopter and that of the new unity are negligible (0.0025%), but the scale of values expressed by the new unity is closer to the ideal scale of angular measurements. (With the new unity, the infinite value is only reached for an angle of 180º and the errors due to arithmetical operations are much smaller.) Numerical examples showing the advantages of using the new unity of angular measurements instead of the prism-diopter are presented. A mathematical generalization of the modifying concept (partition of an angle) with which the new unity is based is also provided.


As vantagens práticas de quantificação de um ângulo pela relação de comprimentos lineares em lugar dos de arcos de círculos propiciaram a definição da dioptria- prismática, uma unidade convencional de numeração dos prismas e de medições do estrabismo. Entretanto, um grande inconveniente do uso das dioptrias- -prismáticas para exprimir medidas angulares é a não-linearidade da escala, que alcança um valor infinito para o ângulo de 90º e passa a valores negativos e com magnitudes decrescentes para ângulos crescentes entre 90º e 180º. Como consequência, operações aritméticas e comparações de ângulos com medidas angulares expressas com tais unidades apresentam erros de magnitude muito grande. Para manutenção das vantagens de definição de um ângulo pela dimensão de distâncias retas, mas reduzindo os graves inconvenientes dessa escolha, propõe-se uma nova definição para a dioptria-prismática. Ao invés da condição assimétrica pela qual a dioptria-prismática é definida, a concepção dessa nova unidade é baseada em uma condição geometricamente simétrica, a das relações de um triângulo isósceles (o cateto perpendicular à bissetriz do ângulo e essa própria bissetriz). Essa condição de simetria para a definição da nova unidade corresponde a um avanço conceitual, por reproduzir o critério convencional, já bem aceito, de quantificação do valor do prisma, o de seu desvio mínimo, além de corresponder às condições clínicas de exame do equilíbrio binocular comumente usadas. A diferença absoluta entre os valores unitários da dioptria-prismática e o da nova unidade é negligenciável (0,0025%) mas a escala dos valores expressos pela nova unidade é mais próxima da escala ideal de medidas angulares. (Com a nova unidade, o valor infinito é apenas alcançado para um ângulo de 180º e os erros devidos às operações aritméticas são muito menores.) Dão-se exemplos numéricos mostrando as vantagens de uso da nova unidade de medidas angulares em lugar da dioptria-prismática. Apresenta-se, também, uma generalização matemática do conceito de modificação (partição de um ângulo) pelo qual a nova unidade é baseada.


Subject(s)
Visual Cortex , Weights and Measures , Strabismus , Convergence, Ocular
4.
Arq. bras. oftalmol ; 77(4): 250-255, Jul-Aug/2014. graf
Article in English | LILACS | ID: lil-728666

ABSTRACT

Purpose: One of the challenges in strabismus is to guarantee stability of the surgical corrections. Re-surgeries are often required even after careful diagnosis, planning, and execution. Several factors contribute to this undesired outcome and the existing management strategies are ineffective. The present alternative is to compensate for their consequences. Ocular rotations are evoked by muscular contractions and relaxations (active forces). During eye movement, periocular tissues are stretched, storing part of the kinetic energy, which may be posteriorly recovered (passive forces), whereas the remaining part of the energy is lost via friction and inelastic deformations (dissipative forces). A method for measuring the forces that cause post-surgery eye drift has not been reported. However, this may be indirectly determined as a function of the respective mechanical variables. The estimated ratio between the kinetic energies of a post-surgery eye drift and a normal pursuit eye movement is ~10-15. Theoretically, it can be expected that the addition of continuously acting forces of such magnitudes to the oculomotor system might prevent the undesired post-surgery eye movement. Methods: Several methods for increasing the restraining, dissipative forces to ocular rotations may be conceived. One method is to increase the friction to ocular movements, as for instance, by periocular injection of viscous substances. Another possibility is to use the forces of a magnetic field, which may stabilize the eye in a desired position without avoiding the rotations caused by greater muscular forces acting on it. It has been demonstrated that these forces neutralize the nystagmic movements, whose intensities of mechanical variables are much higher than those of a post-surgery eye drift. Some models of application of this technique are then discussed. Small magnets fixed to the orbit and metallic ferromagnetic elements fixed to the sclera to cover a suitable ...


Objetivo: Um grande problema nos estrabismos é garantir um resultado bom e estável de suas correções cirúrgicas. A necessidade de reoperações é relativamente alta, apesar de cuidadosos procedimentos diagnósticos, planejamento cirúrgico e execução tenham sido tomados. O resultado indesejado é devido a muitos fatores que ainda não são apropriadamente controlados. A alternativa atual é, então, compensar as consequências correspondentes. Rotações oculares são evocadas por contrações e relaxamentos musculares (forças ativas). Nesses movimentos oculares, tecidos perioculares são distendidos, mantendo parte da energia cinética, que pode ser posteriormente recuperada (forças passivas), enquanto outra parte é definitivamente perdida em fricção e deformações inelásticas (forças dissipativas). Não é conhecida a medida das forças que causam um desvio ocular pós-operatório, mas ela pode ser indiretamente determinada como função das respectivas variáveis mecânicas. A relação entre as energias cinéticas de um desvio ocular pós-operatório e de um movimento ocular persecutório normal pode ser então estimada como de cerca 10-15. Teoricamente, pode-se esperar que a adição de forças dessas magnitudes ao sistema oculomotor, continuadamente atuantes, possam prevenir os movimentos pós-operatórios indesejados. Métodos: Podem ser concebidas várias possibilidades de aumento das forças dissipativas, restritivas de rotações oculares. Uma é a de aumentar a fricção aos movimentos oculares como, por exemplo, por injeções perioculares de substâncias viscoelásticas. Outra possibilidade é oferecida por forças de campos magnéticos ...


Subject(s)
Humans , Eye Movements , Oculomotor Muscles/surgery , Secondary Prevention/methods , Strabismus/surgery , Magnetic Fields , Recurrence , Reoperation , Strabismus/complications
6.
Arq. bras. oftalmol ; 74(1): 24-27, Jan.-Feb. 2011. graf, tab
Article in Portuguese | LILACS | ID: lil-589934

ABSTRACT

OBJETIVOS: Determinar as variações no ângulo de posicionamento ocular pós-operatório em pacientes submetidos a cirurgias para correção de estrabismo e identificar possíveis fatores de risco associados a tal ocorrência. MÉTODOS: Foi realizado estudo retrospectivo de 819 pacientes portadores de estrabismo submetidos à cirurgia para correção do desvio ocular entre janeiro de 1995 e dezembro de 2005 no Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo. Os pacientes foram divididos em quatro grupos quanto ao tipo de desvio pré-operatório (esotropia alternante, esotropia monocular, exotropia alternante e exotropia monocular) e as variações no posicionamento ocular foram quantificadas em cada grupo. RESULTADOS: A prevalência de variações no posicionamento ocular (pós-operatório) maiores que 10∆ entre o total de pacientes estudado foi de 33,5 por cento (274 pacientes). Entre estes, foi verificada maior frequência de desvios no sentido exotrópico (178 pacientes ou 65,0 por cento) do que no sentido esotrópico (96 pacientes ou 35,0 por cento), diferença esta que foi estatisticamente significativa (teste do qui-quadrado; p<0,001). CONCLUSÕES: Instabilidade no posicionamento ocular pode ocorrer ao longo do tempo em pacientes submetidos a cirurgias de estrabismo. Tal ocorrência reforça a necessidade do desenvolvimento de alternativas terapêuticas a fim de proporcionar maior estabilidade ao sistema oculomotor no pós-operatório de cirurgias de estrabismo.


PURPOSE: To determine the drift variations of the postoperative alignment in patients who underwent strabismus surgery and to identify possible risk factors associated with such occurrence. PATIENTS AND METHODS: We reviewed the variations in postoperative alignment drift of 819 patients who underwent rectus muscle surgery from January, 1995 to December, 2005 at the Hospital de Clínicas da Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo. The patients were divided into four groups according to the type of deviation (alternating esotropia, monocular esotropia, alternating exotropia and monocular exotropia). Changes in eye positioning were quantified in each group. RESULTS: The prevalence of variations in the postoperative angle (considering variations more than 10 ∆) among the total of studied patients was 33.5 percent (274 patients). In those patients, a higher frequency was found in the exotropic direction (178 patients or 65.0 percent) than in the esotropic direction (96 patients or 35,0 percent), and this difference was statistically significant (chi-square test; p<0.001). CONCLUSIONS: Eye positioning instability can occur over time in patients who underwent strabismus surgery. This incident reinforces the need for the development of alternative therapies in order to provide greater stability to the oculomotor system in the follow-up of strabismus surgery.


Subject(s)
Adolescent , Child , Child, Preschool , Female , Humans , Male , Postoperative Complications , Strabismus/surgery , Prevalence , Retrospective Studies , Risk Factors
7.
Arq. bras. oftalmol ; 73(4): 379-383, July-Aug. 2010.
Article in Portuguese | LILACS | ID: lil-560617

ABSTRACT

As primitivas cirurgias de estrabismo, as miotomias e as tenotomias, eram feitas, simplesmente, seccionando-se o músculo ou o seu tendão, sem nenhuma sutura. Estas cirurgias eram feitas, geralmente, em um só olho, tanto em pequenos como em grandes desvios e os resultados eram pouco previsíveis. Jameson, em 1922, propôs uma nova técnica cirúrgica, usando suturas e fixando, na esclera, o músculo seccionado, tornando a cirurgia mais previsível. Para as esotropias, praticou recuos de, no máximo, 5 mm para o reto medial, o que se tornou uma regra para os demais cirurgiões que o sucederam, sendo impossível, a partir daí, a correção de esotropias de grande ângulo com cirurgia monocular. Rodriguez-Vásquez, em 1974, superou o parâmetro de 5 mm, propondo amplos recuos dos retos mediais (6 a 9 mm) para o tratamento da síndrome de Ciancia, com bons resultados. Os autores revisaram a literatura, ano a ano, objetivando comparar os vários trabalhos e, com isso, concluíram que a cirurgia monocular de recuo-ressecção pode constituir uma opção viável para o tratamento cirúrgico das esotropias de grande ângulo.


The primitive strabismus surgeries, myotomies and tenotomies, were performed simply by sectioning the muscle or its tendon without any suture. Such surgeries were usually performed in just one eye both in small and in large angles with not really predictable results. In 1922, Jameson introduced a new surgery technique using sutures and fixing the sectioned muscle to the sclera, increasing surgery predictability. For the esotropias he carried out no more than 5 mm recession of the medial rectus, which became a rule for the surgeons who followed him, which made it impossible from then on to correct largeangle esotropias with a monocular surgery. Rodriguez-Vásquez, in 1974, exceeded the 5 mm parameter by proposing large recessions of the medial recti (6 to 9 mm) to treat the Ciancia syndrome with good results. The authors revised the literature year after year with the purpose of comparing the several works and concluded that monocular recession-resection surgery may be a feasible option for the surgical treatment of large-angle esotropias.


Subject(s)
Humans , Esotropia/surgery , Oculomotor Muscles/surgery , Ophthalmologic Surgical Procedures/methods
8.
Arq. bras. oftalmol ; 72(6): 751-754, Nov.-Dec. 2009. tab, ilus
Article in English | LILACS | ID: lil-536765

ABSTRACT

PURPOSE: Intermittent exotropia may be decreased by stimulation of accommodative convergence. Once excessive accommodation has been related to myopia, our objective was to evaluate refractive errors changes in children under overcorrecting minus lens therapy. METHODS: A retrospective chart review of 21 children with intermittent exotropia was performed. All patients were treated with occlusion, and a 13-patient subset of them received overminus lens therapy (group A). Eight children received spectacles as necessary (group B). Initial age, age interval, initial spherical equivalent (SE), and magnitude of overcorrection were considered as co-variables of the mean variation in refractive error (SE of each eye) between groups, through a multivariate analysis. RESULTS: Overcorrection used in group A ranged from 0.5 D to 3.5 D (2.46 ± 0.87 D). Although initial SE of each eye was significant different between group A and B (OD - p=0.02; OS - p=0.01), initial age (p=0.69), age interval (p=0.90), and mean variation in refractive errors (p=0.36) did not differ between groups. Multivariate analysis with linear regression showed no significantly difference regarding all co-variables enrolled. CONCLUSIONS: Treatment of intermittent exotropia with overcorrecting minus lens did not induce refractive errors changes, even considering age, treatment period, initial spherical equivalent and overcorrection magnitude used.


OBJETIVO: A exotropia intermitente pode ser diminuída pela estimulação da convergência acomodativa. Uma vez que uma acomodação excessiva tem sido relacionada à miopização, o objetivo deste trabalho foi o de avaliar alterações nos vícios de refração de crianças submetidas à hipercorreção com lentes negativas. MÉTODOS: Foi realizada revisão dos prontuários de 21 crianças com exotropia intermitente. Todos os pacientes foram tratados com oclusão, sendo que 13 deles foram submetidos à hipercorreção com lentes negativas (grupo A). As 8 crianças restantes receberam prescrições ópticas conforme necessário pelas suas ametropias (grupo B). A idade inicial, tempo de tratamento, equivalente esférico (EE) inicial e magnitude da hipercorreção foram considerados como covariáveis na análise das diferenças das médias de erro refrativo (EE de cada olho) entre os grupos, pela análise multivariada. RESULTADOS: A hipercorreção utilizada no grupo A variou entre 0,5 D e 3,5 D (2,46 ± 0,87 D). Embora o EE inicial de cada olho ter sido significativamente diferente entre os grupo A e B (olho direito - p=0,02; olho esquerdo - p=0,01), a idade inicial (p=0,69), o tempo de tratamento (p=0,90) e a variação média nos erros refrativos (p=0,36) não diferiram entre os grupos. A análise multivariada com regressão linear não mostrou diferença significativa, considerando as covariáveis em questão. CONCLUSÕES: O tratamento de crianças com exotropia intermitente por meio de hipercorreção óptica com lentes negativas não induziu alterações nos vícios de refração, mesmo considerando fatores como idade inicial, o tempo de tratamento, equivalente esférico inicial e a magnitude da hipercorreção utilizada.


Subject(s)
Child , Child, Preschool , Female , Humans , Infant , Male , Eyeglasses , Exotropia/therapy , Refractive Errors/therapy , Epidemiologic Methods , Exotropia/physiopathology , Optometry , Refractive Errors/physiopathology , Time Factors
9.
Arq. bras. oftalmol ; 72(6): 799-804, Nov.-Dec. 2009. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-536774

ABSTRACT

OBJETIVO: Avaliar se a carboximetilcelulose 6,0% é capaz de atuar como modificadora do sistema oculomotor de coelhos por meio de forças de ação viscoelástica, a durabilidade de seu eventual efeito e reações teciduais à aplicação. MÉTODOS: Foram utilizados 25 coelhos da raça Nova Zelândia, divididos em dois grupos experimentais: um tratado com injeção peribulbar de carboximetilcelulose (CMC) 6,0 por cento e um controle que foi submetido à injeção peribulbar de 3,0 cc de soro fisiológico. No grupo tratado com CMC, variou-se o volume total injetado, obtendo-se, assim, quatro subgrupos (1,0, 1,5, 2,0 e 3,0 cc). Foram realizadas medidas da força necessária para promover movimentos tangenciais de adução, avaliação clínica e medidas da pressão intraocular antes, imediatamente após a injeção da substância e no 7º, 30º e 60º dia pós-operatório. A eutanásia dos animais foi realizada no 60º dia pós-operatório para análise histológica dos tecidos perioculares. RESULTADOS: A força média encontrada, 60 dias após a injeção da CMC 6,0 por cento, foi menor no subgrupo tratado 1,0 e maior nos subgrupos tratados 1,5, 2,0 e 3,0 relativamente à força antes da injeção. Nos subgrupos em que houve aumento da força, a análise histológica revelou processo inflamatório do tipo histiocitário com formação de fibrose e a presença da CMC nos tecidos perioculares. CONCLUSÕES: A carboximetilcelulose 6,0 por cento atuou como modificadora do sistema oculomotor de coelhos, podendo facilitar ou dificultar movimentos. Não foi possível concluir se o aumento da força deveu-se apenas ao processo inflamatório ou à soma de inflamação com um possível atrito viscoso provocado pela CMC.


PURPOSE: To determine the effects of 6.0% carboxymethylcellulose (CMC) in modifying the oculomotor system of rabbits by means of viscoelastic action forces, the durability of this effect and possible inflamatory reaction. METHODS: Twenty-five New Zealand rabbits were divided into two experimental groups: one treated with a peribulbar injection of 6.0 percent CMC and a control group submitted to peribulbar injection of 3.0 cc of physiological saline. The group submitted to peribulbar CMC injection was divided into four subgroups respectively receiving the following volumes: 1.0, 1.5, 2.0 and 3.0 cc. The force needed to promote tangential adduction dislocations, external ophthalmologic signs and intraocular pressure were evaluated. The animals were sacrificed on the 60th day after the injection for histological analysis. RESULTS: The mean force detected 60 days after the injection of 6.0 percent CMC was lower in the 1.0 treated subgroup and higher in the 1.5, 2.0 and 3.0 treated subgroups relative to the force before injection. Histological analysis revealed histiocytic infiltration with fibrosis in the subgroups in which there was an increase in force and the presence of CMC in periocular tissues. CONCLUSIONS: 6.0 percent CMC acted as a modifier of the oculomotor system of rabbits, facilitating or impairing movements. It was not possible to conclude whether the increase in force occurred as a consequence of the inflammatory process alone or of the sum of inflammation and a possible viscous attrition provoked by CMC.


Subject(s)
Animals , Female , Rabbits , Carboxymethylcellulose Sodium/administration & dosage , Oculomotor Muscles/drug effects , Orbit/drug effects , Carboxymethylcellulose Sodium/adverse effects , Elasticity Imaging Techniques/methods , Histiocytes/pathology , Models, Animal , Oculomotor Muscles/pathology , Oculomotor Muscles/physiology , Orbital Myositis/etiology , Orbital Myositis/pathology , Orbital Myositis/physiopathology
10.
Arq. bras. oftalmol ; 72(5): 585-615, set.-out. 2009. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-534177

ABSTRACT

Analisam-se particularidades inerentes ao estudo dos estrabismos, tais como as dificuldades para suas definições e os diferentes modos com os quais eles podem ser concebidos, a relatividade com que as posições binoculares possam ser interpretadas e os elementos referenciais necessários para a circunscrição dessas questões. A partir daí, discute-se o conceito de posição primária do olhar e as condições de sua operacionalização, concluindo-se pela impossibilidade de concretização desse ponto "zero", a partir do qual seriam feitas as medidas dos estrabismos e as quantificações de movimentos oculares. A seguir, passa-se ao exame da construção dos múltiplos sistemas referenciais aplicáveis à quantificação dos estrabismos, de cuja falta de consenso sobre qual deles usar decorrem implicações práticas elementares, como a falta de padronização do modo de superposição ortogonal de prismas, para a medida de desvios combinados, horizontal e vertical. Comenta-se a assimetria funcional das rotações oculares e suas exceções. Também se analisa a precisão com que se pode fazer a medida de um estrabismo, levando à conclusão sobre a impropriedade de uso de medidas fracionárias com as unidades angulares mais comumente usadas. Finalmente, são comentados alguns problemas técnicos dessas avaliações, tais como o das dificuldades operacionais relacionadas à dioptria-prismática, os subordinados ao uso de prismas e os da ocorrência de efeitos prismáticos pelo uso de lentes convencionais.


Some particular points concerning the study of strabismus are analyzed, specially, the difficulties for definitions and the different ways it can be conceived, besides the relativity of binocular positions interpretation, and the necessary referential elements for circumscribing such questions. Then, the concept of primary position of gaze is discussed as well as the conditions for its operational attainment, leading to the conclusion that it is materially impossible to achieve this "zero" point, from which all other measurements of strabismus or ocular movements should be done. In sequence, the construction of multiple referential systems applying the quantification of strabismus are examined. The lack of consensual agreement about which should be used as the standard system causes elementary practical implications, as the lack of agreement about how to superimpose orthogonal prisms for the measurement of associated horizontal and vertical deviations. The functional asymmetry of ocular rotations and its exceptions are commented. The accuracy that the measurements of strabismus can be performed is analyzed, leading to the conclusion that fractional figures using the commonest angular unities are improper. At last, some technical problems related to such evaluations are also commented, as operational difficulties related to prism-diopter unity, concerning the use of prisms, and prismatic effects due to the use of conventional optical glasses.


Subject(s)
Humans , Strabismus , Consensus , Eye Movements/physiology , Lenses , Posture/physiology , Reference Values , Rotation , Refraction, Ocular/physiology , Strabismus/diagnosis , Strabismus/physiopathology , Vision, Binocular/physiology
11.
Arq. bras. oftalmol ; 72(1): 47-56, jan.-fev. 2009. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-510021

ABSTRACT

OBJETIVO: Demonstrar a viabilidade da cirurgia monocular no tratamento das esotropias de grande ângulo, praticando-se amplos recuos do reto medial (6 a 10 mm) e grandes ressecções do reto lateral (8 a 10 mm). MÉTODOS: Foram operados, com anestesia geral e sem reajustes per ou pósoperatórios, 46 pacientes com esotropias de 50δ ou mais, relativamente comitantes. Os métodos utilizados para refratometria, medida da acuidade visual e do ângulo de desvio, foram os, tradicionalmente, utilizados em estrabologia. No pós-operatório, além das medidas na posição primária do olhar, foi feita uma avaliação da motilidade do olho operado, em adução e em abdução. RESULTADOS: Foram considerados quatro grupos de estudo, correspondendo a quatro períodos de tempo: uma semana, seis meses, dois anos e quatro a sete anos. Os resultados para o ângulo de desvio pós-cirúrgico foram compatíveis com os da literatura em geral e mantiveram-se estáveis ao longo do tempo. A motilidade do olho operado apresentou pequena limitação em adução e nenhuma em abdução, contrariando o encontrado na literatura estrabológica. Comparando os resultados de adultos com os de crianças e de amblíopes com não amblíopes, não foram encontradas diferenças estatisticamente significativas entre eles. CONCLUSÃO:Em face dos resultados encontrados, entende-se ser possível afirmar que a cirurgia monocular de recuo-ressecção pode ser considerada opção viável para o tratamento das esotropias de grande ângulo, tanto para adultos quanto para crianças, bem como para amblíopes e não amblíopes.


PURPOSE: To demonstrate the feasibility of monocular surgery in the treatment of large-angle esotropias through large recessions of the medial rectus (6 to 10 mm) and large resections of the lateral rectus (8 to 10 mm). METHODS: 46 patients were submitted to surgery. They had esotropias of 50Δor more that were relatively comitant. The patients were operated under general anesthesia and received no adjustable sutures. The methods used for refractometry, measurement of visual acuity and angle of deviation were those traditionally used in strabismology. Postoperatively, measurements in primary position (and side gaze) were carried out, along with assessments of limitations to adduction or abduction of the operated eye. RESULTS: Four groups comprised the study according to four periods of time: one week, six months, two years and four to seven years. The results for the postoperative angle of deviation were compatible with those reported in the literature, and remained stable in the folllowup. The motility of the operated eye presented a slight limitation in adduction and no limitation in abduction, contradicting the findings presented in the strabologic literature. No statistically significant differences were detected in the comparison between adults and children, neither regarding amblyopes and non-amblyopes. CONCLUSION: Monocular recession-resection surgery seems to be a valid option in the treatment of large-angle esotropias, both for adults and children, as well as for amblyopes and non-amblyopes.


Subject(s)
Adolescent , Child , Child, Preschool , Female , Humans , Infant , Male , Young Adult , Esotropia/surgery , Oculomotor Muscles/surgery , Amblyopia/pathology , Amblyopia/surgery , Esotropia/pathology , Eye Movements/physiology , Ophthalmologic Surgical Procedures/methods , Postoperative Period , Time Factors , Treatment Outcome , Visual Acuity/physiology , Young Adult
14.
Arq. bras. oftalmol ; 71(4): 589-591, jul.-ago. 2008. ilus
Article in English | LILACS | ID: lil-491896

ABSTRACT

This case report describes clinical data from mother and son with bilateral Brown's syndrome and highlights possible genetically determined predispositions.


Este relato de caso descreve achados clínicos de mãe e filho com síndrome de Brown bilateral e discute a possibilidade de predisposição genética.


Subject(s)
Adult , Child , Female , Humans , Male , Exotropia/diagnosis , Exotropia/genetics , Eye Movements/physiology , Nuclear Family , Syndrome , Vision Tests
16.
Arq. bras. oftalmol ; 69(4): 523-529, jul.-ago. 2006. tab
Article in Portuguese, English | LILACS | ID: lil-435737

ABSTRACT

OBJETIVO: Avaliar a eficácia da toxina botulínica no tratamento de estrabismo horizontal em crianças com paralisia cerebral. MÉTODOS: Um grupo de 24 pacientes com paralisia cerebral e estrabismo horizontal (17 esotropias variando de 25delta a 45delta e 7 exotropias variando de 20delta a 45delta), com idades variando entre 6 a 156 meses, foram tratadas com toxina botulínica (34 músculos retos mediais e 14 retos laterais). As crianças foram submetidas a exame oftalmológico completo. A injeção de toxina, utilizando-se a pinça de Mendonça, foi realizada sob sedação. O seguimento foi realizado mediante avaliação aos 7 dias, 15 dias e a seguir mensalmente. O resultado foi considerado bom quando se obteve desvio < 10delta após seis meses de seguimento. Caso o resultado não fosse satisfatório uma segunda aplicação poderia ser realizada. RESULTADOS: No grupo das esotropias, no seguimento de dois anos (n=17) 47,1 por cento tiveram bons resultados, com apenas uma aplicação de toxina botulínica. Todos estes pacientes tinham desvio prévio < 35delta. No grupo das exotropias, após a primeira aplicação, não foi encontrado qualquer resultado satisfatório no sexto mês de seguimento. Os efeitos colaterais foram: hemorragia subconjuntival em 4 pacientes (16,7 por cento), desvio vertical transitório em 4 pacientes (16,7 por cento) e blefaroptose transitória em 22 (91,7 por cento). CONCLUSÕES: O uso da toxina botulínica pode ser considerado como boa alternativa de tratamento em crianças com diagnóstico de paralisia cerebral e esotropia.


PURPOSE: To evaluate the efficacy of botulinum toxin injection in the treatment of horizontal strabismus in children with cerebral palsy. METHODS: A group of 24 patients, age 6 - 156 months, with cerebral palsy and horizontal strabismus (17 esotropias ranging from 25 to 45 PD and 7 exotropias ranging from 20 to 45 PD) were treated with botulinum toxin (34 medial rectus and 14 lateral rectus muscles). The children underwent full ophthalmic examination. The injection treatment was performed after sedation using Mendonça's forceps. The follow-up was done after 7 days, 15 days and monthly. Deviation less or equal of 10 PD after 6 months of follow-up was considered successful. However, if patients did not achieve this result a second application could be performed. RESULTS: In the group of esotropia (n=17) 47.1 percent had successful results with only one application after two years of follow-up. All of these patients had previous deviation less than or equal to 35 PD. In the exotropia group a single injection was not sufficient to achieve successful result. The side effects included: subconjutival hemorrhage in 4 (16.7 percent) patients, transient vertical deviation in 4 (16.7 percent) and transient ptosis in 22 (91.7 percent). CONCLUSION: The use of botulinum toxin was a good alternative in the treatment of children with cerebral palsy and esotropia.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Botulinum Toxins, Type A/therapeutic use , Cerebral Palsy/complications , Neuromuscular Agents/therapeutic use , Strabismus/drug therapy , Strabismus/etiology , Follow-Up Studies , Prospective Studies , Treatment Outcome
17.
Arq. bras. oftalmol ; 69(1): 63-70, jan.-fev. 2006. ilus, tab
Article in Portuguese | LILACS | ID: lil-420820

ABSTRACT

OBJETIVO: Determinar se forcas de atrito viscoso podem, sob o ponto de vista quantitativo, agir como possíveis promotoras de estabilizacão ocular com manutencão dos movimentos rotacionais, dando nocão dos valores necessários para a aplicabilidade no sistema ocular. MÉTODOS: Um modelo mecânico foi elaborado para a medida de forcas necessárias para vencer o atrito de uma esfera de alumínio parcialmente mergulhada em um líquido viscoso. Foram testadas solucões de carboximetilcelulose de 1 por cento a 6 por cento (com variacão de 0,5 por cento). Outra variável foi a área de contato entre a esfera e o líquido viscoso. RESULTADOS: A forca encontrada, após correcões e descontos apropriados, foi significativa (acima de 5 gf) nas solucões de carboximetilcelulose a partir de 3,5 por cento na maior área de contato (587,8 mmy), nas solucões de carboximetilcelulose a partir de 4,5 por cento na área intermediária (335,9 mmy), nas solucões de carboximetilcelulose a 5,5 por cento e 6,0 por cento na menor área (167,9 mmy). CONCLUSAO: Alguns dos líquidos viscosos testados aparentemente são capazes de obter forca de atrito suficiente para a estabilizacão ocular, com destaque para as solucões de carboximetilcelulose a 5,5 por cento e 6,0 por cento que obtiveram bons resultados na menor área de contato.


Subject(s)
Humans , Carboxymethylcellulose Sodium , Eye Movements/physiology , Models, Biological , Rotation , Biomechanical Phenomena , Elasticity , Membrane Proteins , Viscosity
18.
Arq. bras. oftalmol ; 68(6): 743-745, nov.-dez. 2005. tab, graf
Article in Portuguese | LILACS | ID: lil-420180

ABSTRACT

OBJETIVO: Medir a extensão de aderências mioesclerais no quadragésimo dia de pós-operatório. MÉTODOS: Quinze coelhos da raça Nova Zelândia foram distribuídos em três grupos de cinco coelhos, submetidos à operação de desinserção do músculo reto superior de ambos os olhos, e reposicionamento no local da inserção original: o Grupo SP para o controle, sutura com fio de poliglactina 910 (Vicryl® 6-0), Grupo AF, adesivo de fibrina (Beriplast-P®), e Grupo AC, adesivo de cianoacrilato (Histoacryl®). Antes da desinserção muscular, foram medidas as distâncias do gancho sob o músculo ao limbo, borda medial e lateral. Após quarenta e cinco dias, estes olhos foram reoperados e as medidas realizadas novamente. RESULTADOS: Não houve diferença significativa entre os adesivos estudados, quanto à adesão tecidual e às distâncias encontradas do músculo ao limbo nos pré- e pós-operatórios. CONCLUSÕES: As aderências teciduais encontradas foram provavelmente devidas aos processos de cicatrização, não dependendo dos materiais estudados.


Subject(s)
Animals , Rabbits , Materials Testing , Oculomotor Muscles/anatomy & histology , Oculomotor Muscles/surgery , /therapeutic use , Tissue Adhesives/therapeutic use , Chi-Square Distribution , Cyanoacrylates/therapeutic use , Disease Models, Animal , Fibrin Tissue Adhesive/therapeutic use , Intraoperative Period , Oculomotor Muscles/drug effects , Postoperative Care , Preoperative Care , Suture Techniques , Strabismus/surgery
19.
Arq. bras. oftalmol ; 68(5): 599-607, set.-out. 2005. ilus, tab
Article in Portuguese | LILACS | ID: lil-417807

ABSTRACT

OBJETIVO: Medir o tempo da operação, as forças de adesão tecidual e fazer estudo clínico e histopatológico de reinserções oculares de retos superiores de coelho com quatro diferentes adesivos teciduais, como alternativa à utilização de sutura de poliglactina em operações de estrabismo. MÉTODOS: Cem coelhos da raça Nova Zelândia foram distribuídos em dois experimentos, I-A e I-B, de cinqüenta coelhos cada, e estes em cinco grupos de dez coelhos (vinte olhos), submetidos à operação de desinserção do músculo reto superior de ambos os olhos, e reinserção com sutura (controle) com poliglactina 910, 6-0 ou adesivos teciduais, de fibrina, cianoacrilato, albumina-glutaraldeído e gelatina-resorcinol-formaldeído-glutaraldeído. Os coelhos do experimento I-A foram submetidos à dinamometria nos dez minutos após o reposicionamento muscular. Os coelhos do experimento I-B foram submetidos à avaliação clínica e histopatológica. RESULTADOS: Verificou-se melhor desempenho dos adesivos teciduais no tempo gasto para realizar a operação. Quanto à força de adesão, nenhum dos adesivos apresentou 100 por cento de casos com resistência à tensão igual ou maior que 100 gf. Com relação às avaliações clínica e histopatológica, quanto à presença dos sinais inflamatórios e suas intensidades o adesivo fibrínico utilizado neste trabalho apresentou melhor desempenho do que a sutura de poliglactina 910, tendo os demais adesivos apresentado resultados piores, quando comparados aos do grupo controle (sutura). CONCLUSÃO: Os adesivos estudados mostraram-se inadequados para as operações de estrabismo.


Subject(s)
Animals , Male , Rabbits , Oculomotor Muscles/surgery , Suture Techniques , Tissue Adhesives/therapeutic use , Oculomotor Muscles/pathology , Tensile Strength , Time Factors , Tissue Adhesions , Wound Healing
20.
Arq. bras. oftalmol ; 68(5): 667-673, set.-out. 2005. ilus, tab
Article in Portuguese | LILACS | ID: lil-417820

ABSTRACT

OBJETIVOS: Avaliação microscópica dos sinais da reação inflamatória causada pela fixação de implante orbitário (ímã, recoberto por ouro). MÉTODOS: Estudo experimental em 54 coelhas adultas, divididas em três grupos de 18, com 3 subgrupos de 6, avaliação com uma, três e seis semanas de pós-operatório. Fixação, no rebordo inferior da órbita, de implante (ímã e ouro) por meio de cola, parafuso ou fio inabsorvível (Mersilene 5.0®). As órbitas contralaterais (sem implante) compuseram o grupo-controle. RESULTADOS: Sinais histológicos de reação inflamatória à fixação orbitária do implante foram observados, com cianoacrilato, parafuso, ou sutura inabsorvível (Mersilene 5.0®), até a sexta semana pós-operatória, com predomínio do processo inflamatório crônico e fibrótico cicatricial, sem demonstrar diferenças estatisticamente significativas na maior parte dos casos. CONCLUSÃO: O exame histopatológico demonstrou, na maior parte das órbitas com e sem implante, presença de reação inflamatória aguda e crônica até a sexta semana pós-operatória, com predomínio de processo inflamatório crônico e fibrótico cicatricial, sem demonstrar, na maior parte dos casos, diferenças estatisticamente significante entre os grupos experimental e controle.


Subject(s)
Animals , Female , Rabbits , Foreign-Body Reaction/pathology , Gold , Magnetics/adverse effects , Orbit/surgery , Orbital Implants/adverse effects , Acute Disease , Chronic Disease , Fibrosis/pathology , Orbit/pathology , Time Factors