1.
Chinese Journal of Medical Instrumentation ; (6): 354-356, 2012.
Article in Chinese | WPRIM | ID: wpr-342929

ABSTRACT

A kind of coronary stent was made from Nickel-free stainless steel, and the technological process of the stent was studied. A preferable flexible and support force stent was simulated by a commercial finite element code ANSYS with laser cutting, pickling and vacuum annealing. This kind of coronary stent has more superiority. It was also presented that a self designed automatic stent electro-polishing device, which greatly improve efficiency and quality, and the optimization electro-polishing process was put forward.


Subject(s)
Materials Testing , Nickel , Prosthesis Design , Stainless Steel , Stents , Technology
2.
Chinese Journal of Tissue Engineering Research ; (53): 2899-2902, 2010.
Article in Chinese | WPRIM | ID: wpr-402452

ABSTRACT

BACKGROUND: Magnalium which is potential to be the medical biodegraded metal implant is more and more interesting,but it must be well biocompatibility to human body.OBJECTIVE: To evaluate the sensitization of magnalium (AZ31B).METHODS: A total of 35 guinea pigs were randomly divided into saline group (negative control group,n=10),5% volume of formaldehyde (positive control group,n=10),and AZ31B group (n=15).Sensitization test at the maximal dosage was performed according to "Biological evaluation of medical devices-Part 10: Tests for irritation and delayed-type hypersensitivity",including intracutaneous induction,local induction,and provocation.Patch was removed after 6,24,48,and 72 hours,and the skin response was classified accordingto Magnusson and Kligman criteria.Patch was removed after 72 hours,and skin was performed with biopsy,stained with FIE staining,and observed under optic microscope.RESULTS AND CONCLUSION: Sensitization response was not tested in both negative control group and AZ31B group at 24,48,and 72 hours after patch removal; however,moderate erythema was observed in the positive control group.Optic microscope demonstrated that criteria of allergy such as spongiosis,edema,and diffuse as well as perivascular mononuclear infiltration was not observed in the AZ31B group,but a few basophilic calls ware observed.This suggested that AZ31B was biologically safe for sensitization.

3.
Journal of Biomedical Engineering ; (6): 856-878, 2008.
Article in Chinese | WPRIM | ID: wpr-342727

ABSTRACT

The objective of this experimental study was to assess the effects of a new kind of drug eluting coronary stent. Fourteen mini-pigs were used; seven normal stainless stents and seven new drug eluting stents were implanted in their normal coronary arteries, respectively. Angiography was performed and followed by pressure-fixation of the coronary arteries for light and electron microscopic examinations at the end of three months after implantation. Repeated angiography showed that all the stented coronary segments were open. With no additional antithrombotic treatment, there was no thrombus formed in the stented coronary segments. Scanning electron microscopy analysis showed the implanted stent surface was covered by endomembrane without thrombus formation. The endothelial cell in the membrane was clear and lined by the direction of blood flow. Histomorphological analysis revealed the neointima in normal stainless stent group was thicker than that in new drug eluting stent group, and the neointima was composed of smooth muscle cell and extracellular matrix. The result of this study shows that this kind of stent could reduce the rate of the re-stenosis and occlusion of PTCA. This stent can be used in clinical trials.


Subject(s)
Animals , Angioplasty, Balloon, Coronary , Coated Materials, Biocompatible , Chemistry , Coronary Restenosis , Drug-Eluting Stents , Random Allocation , Swine , Swine, Miniature , Titanium , Chemistry
4.
Journal of Biomedical Engineering ; (6): 1101-1122, 2006.
Article in Chinese | WPRIM | ID: wpr-320411

ABSTRACT

Medical implantable stainless steels are widely used in medical field due to their excellent properties, besides its allergic response to human body, the nickel ion released from the steels due to corrosion has the harm of malformation and carcingenesis. The mechanical property, corrosion resistance and blood compatibility of a new nickel-free stainless steel (BIOSSN4) is researched in this paper. Compared with the traditional 316L medical stainless steel, BIOSSN4 shows wide future applications because of its better combination of strength and toughness, good corrosion resistance and biocompatibility.


Subject(s)
Humans , Biocompatible Materials , Chemistry , Toxicity , Corrosion , In Vitro Techniques , Materials Testing , Nickel , Chemistry , Toxicity , Platelet Adhesiveness , Stainless Steel , Chemistry , Toxicity , Surface Properties