Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Imaging ; (12): 598-601,604, 2017.
Article in Chinese | WPRIM | ID: wpr-706373

ABSTRACT

Purpose To explore the application of vascular echo tracking technology in early stage vascular lesions of type 2 diabetes mellitus combined with proteinuria with normal intima and medial membrane of femoral artery,in order to provide evidence for early clinical intervention and to reduce complications of diabetes patients.Materials and Methods Fifty-two patients with type 2 diabetes mellitus diagnosed in Longgang Central Hospital from March 2015 to July 2016 were selected,20in proteinuria group and 32 in group without proteinuria.30 patients at the same stage with normal physical examination results were selected as control group.Vascular echo-tracking technology was used to check femoral arterial elasticity on both sides of the examinee,including stiffness parameter (β),pressure-strain elasticity modulus (Ep),arterial compliance (AC),augmentation index (AI) and one-point pulse wave velocity (PWVβ).Results ① Ep,β and PWVβ of femoral artery in diabetes patients were higher than those in control group,and AC was lower than that in control group.The differences was of statistical significance (P<0.05).There was no statistical difference in AI between the two groups (P>0.05).② Ep,β and PWVβ of femoral artery for patients in proteinuria group were higher than those in group without proteinuria and AC was also lower.The difference was of statistical significance (P<0.05).There was no statistical difference in AI between the two groups (P>0.05).③ After judgment and analysis,AC and diastolic blood pressure were of statistical significance for judgment,and sensitivity was 92.3% and specificity 100.0% when adopting its function to diagnose diabetes femoral arterial elasticity.Conclusion Vascular echo-tracking technology can accurately assess femoral elasticity for diabetes patients and is of great significance in early preventive treatment of diseases.The appearance ofproteinuria indicates that vascular elasticity function decreases dramatically.

2.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 117-121, 2017.
Article in Chinese | WPRIM | ID: wpr-711991

ABSTRACT

Objective To explore the value of two dimentional colour Doppler flow image (2D-CDFI) combined with three-dimensional color power angiography (3D-CPA) in diagnosis of placenta accreta.Methods A total of 43 pregnant women at risk of placenta accreta selected from September 2010 to August 2015 were enrolled,and underwent 2D-CDFI and 3D-CPA to scan entire placenta.Taking the results of clinical outcome and delivery pathology of the placenta as standard,the ultrasound characteristics of 2D-CDFI and 3D-CPA were analyzed.Results Taking the results of clinical outcome and delivery pathology of the placenta as standard,24 were proved with placenta increta,3 patients with adherent placenta,2 patients with placenta percreta,14 patients with no placenta implantation.Out of 43 cases,29 cases displayed the placental thickening and rich blood vessels in placenta,and at interface of placenta and bladder wall in 2D-CDFI.For 2D-CDFI,19 cases were correctly diagnosed with placenta accrete,while 6 cases were mis-diagnosed and 4 cases missed diagnosed,the diagnosis coincidence rate by 2D-CDFI was 65.5% (19/29).The ultrasound characteristics displayed irregular arranged myometrial arcuate artery,rich blood vessels at interface of placenta and bladder wall in 3D-CPA.For 3D-CPA,23 cases were correctly diagnosed with placenta accrete,3 cases were misdiagnosed,the diagnosis coincidence rate by 3D-CPA was 79.3% (23/29).For 3D-CPA combined 2D-CDFI,1 case missed diagnosed,the diagnosis coincidence rate by combination 2D-CDFI with 3D-CPA was 96.6% (28/29).Conclusions Placenta accrete can all be prenatally diagnosed by characteristic ultrasonic features of 2D-CDFI and 3D-CPA.But 3D-CPA can clearly display the range of placenta accrete lesions and the depth of the blood vessels diffused,has more advantage than two-gray scale ultrasound and 2D-CDFI and has broad application in clinic.

3.
Chinese Journal of Medical Ultrasound (Electronic Edition) ; (12): 61-64, 2014.
Article in Chinese | WPRIM | ID: wpr-636325

ABSTRACT

Objective To analyze the ultrasonographic features of fetal palate in the second and third trimester. Methods Two-dimensional ultrasound was performed in 1 885 fetuses during 21 to 36 gestational weeks of pregnancy, including 1 023 cases in 2nd trimester and 862 cases in 3nd trimester. The normal fetal palate ultrasound images were conifrmed by postnatal examination. In the ultrasound examination, fetal palate coronary plane was scanned through submandibular region, oral ifssure and prootic region;longitudinal plane was scanned through oral ifssure. The detection rate of completely and continuously displayed fetal palate was calculated. Results In prenatal ultrasonography, the normal fetal hard palate was shown as a bright band and the normal soft palate as a hypoechoic band in coronary section through fetal submandibular region, oral ifssure and prootic region. The detection rate was 76%(777/1 023)in 2nd trimester group and 53%(458/862) in 3rd trimester group. The normal fetal palate was shown as continuous camber echogenic band in longitudinal plane through oral ifssure. The detection rate was 49%(501/1 023) in 2nd trimester group and 13%(113/862) in 3rd trimester group. The detection rate was 94%(961/1 023) in 2nd trimester group and 56%(483/862) in 3rd trimester group by the combination of two scanning approaches. Conclusions There is usually an obvious gap between mandible gristles in 2nd trimester fetus. Fetal palate is accessible regardless of fetal head position by coronary scanning through submandibular region, oral ifssure and prootic region and longitudinal scanning through oral ifssure. These planes could display fetal palate well, and might be useful in detecting isolated secondary cleft palate. But these scanning approaches and planes might not suitable for routine screening due to operator dependence.

4.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 2487-2489, 2011.
Article in Chinese | WPRIM | ID: wpr-421941

ABSTRACT

ObjectiveTo investigate the diagnosis value of intracardiac echocardiography in cesarean section scar pregnancy. MethodsCavity ultrasound was applied in patients of cesarean scar pregnancy with sonographic features and treatment. ResultsIn 52 patients, ultrasound diagnosed accurately in 45 cases, diagnosis accurate rate was 86.5% (45/52). Sonogram showed gestational sac simply type in 16 cases, mixed echo-type( or mass-based) of 36cases. In 52 cases of CSP, according to their clinical and sonographic features ,2 cases of uterine scar lined laparotomy and the uterus excision repair;three cases of laparoscopic removal of uterine scar pregnancy lesion repair. 6 patients to methotrexate;five cases of abdominal surgery;36 routine uterine arterial embolization in the ultrasound monitor after curettage. ConclusionUltrasound could apply in cesarean scar pregnancy timely,and accurate diagnosis was made;sonographic features according to the patients,help choose the appropriate clinical treatment,and assess efficacy.

5.
Chinese Journal of Postgraduates of Medicine ; (36): 21-24, 2011.
Article in Chinese | WPRIM | ID: wpr-416031

ABSTRACT

Objective To explore the application value of ultrasound in the diagnosis and treatment for cesarean scar pregnancy. Method The ultrasonic features, clinical treatment of 42 cases of cesarean scar pregnancy were reviewed retrospectively. Results Among 42 patients,35 patients (83.3% ,35/42) were diagnosed accurately by ultrasound. The sonographic appearance showed 15 cases were gestational sac-type and 22 cases were mixed mass-type,the other 5 cases were classified into type three in which the gestational sac mostly located at the uterine cavity and only the inferior part implanted in the cesarean scar. Uterine artery embolisation and suction curettage with the sonographic guidance with 2 cases, intra-amniotic administration of MTX under sonographic guidance with 15 cases, expectant treatment with 20 cases or complex treatment with 5 cases. During treatment,ultrasonography showed focus of infection was shrinked gradually and blood flow disappeared, blood (3 -human chorionic gonadotrophin was decreased to normal level. ConclusionUltrasound can diagnose cesarean scar pregnancy promptly and accurately, proportionate treatment would be selected according to the type of cesarean scar pregnancy, and also can evaluate the therapeutic effect.

6.
Chinese Journal of Postgraduates of Medicine ; (36): 38-39, 2009.
Article in Chinese | WPRIM | ID: wpr-414481

ABSTRACT

Objective To evaluate the diagnostic value of color Doppler ultrasound to diagnose senile cataract and complication.Method Color Doppler ultrasound were used to check and analyze 185 eyes senile cataract of 120 patients and were compared with slit-lamp.Results In initial phase of senile cataract,the accuracy of ultrasonography was lower than slit-lamp.The false negative ratio of ultrasound was 15.22%(7/46).In middle and last phase of senile cataract,the relevant ratio of ultrasonography Was 100.00%(139/139).Conclusions The diagnosis sensitivity of color Doppler ultrasound in senile cataract is similar with slit-lamp.Ultrasound is the first choice to diagnose senile cataract in middle and last phase,especially when it is not seen by funduscope.Color Doppler ultrasound is an important way to diagnose senile cataract and complication.

SELECTION OF CITATIONS
SEARCH DETAIL