Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Coluna/Columna ; 18(3): 226-230, July-Sept. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019783

ABSTRACT

ABSTRACT Objective The use of pedicle screws was a milestone for modern spinal surgery. This type of fixation, due to its superior biomechanics, gave greater fixation power, greater capacity to withstand the pulling forces and, therefore, greater stability and lower rates of pseudoarthrosis. Fixation of the lumbosacral junction, even with the development of these new implants, remains a challenge mainly because the considerable rates of pseudoarthrosis. The use of iliac screws solves the biomechanical difficulties. However, its use shows high rates of surgical wound problems. The S2-Alar-Iliac screw (S2AI) came as a solution to these complications. The lack of studies about anatomical and anthropometric parameters in the Brazilian population justifies the study. Methods Eleven hip tomographies of Brazilian adult males were analyzed by four evaluators. The right and left sides were considered. In each patient, measurements were made of greater and shorter bone length, greater and smaller bone diameter, distance from the entry point to the skin, sagittal and axial angles related to the hypothetical insertion of an S2AI screw and compared to the same measurements obtained with the iliac screw. Results The mean bone length was 136.7 mm, the greatest bone diameter was 24.8 mm, the smallest bone diameter was 19.7 mm and the distance from the screw to the skin was 42.1 mm for the S2AI screw. Conclusions The obtained data present an average of the sample that can be useful in the decision of the surgical technique in the studied group. Level of evidence I; Diagnostic Studies (Anatomical Investigation).


RESUMO Objetivo O uso de parafusos pediculares foi um marco para a cirurgia moderna de coluna vertebral. Esse tipo de fixação, devido a sua biomecânica superior, deu maior poder de fixação, maior capacidade de resistir às forças de arrancamento e, portanto, maior estabilidade e menores taxas de pseudoartrose. A fixação da junção lombossacra, mesmo com o desenvolvimento destes novos implantes, permanece um desafio devido, principalmente, às consideráveis taxas de pseudoartrose. O uso de parafusos de ilíaco resolve o problema biomecânico. Entretanto, seu uso mostra elevadas taxas de problemas na ferida operatória. O parafuso de S2-Alar-Ilíaco (S2AI) veio como solução para essas complicações. A falta de estudos acerca dos parâmetros anatômicos e antropométricos na população brasileira justifica o estudo realizado. Métodos Foram analisadas 11 tomografias de bacia de homens brasileiros adultos por 4 avaliadores. Foram considerados os lados direito e esquerdo. Em cada paciente foram feitas medidas de maior e menor comprimento ósseo, maior e menor diâmetro ósseo, distância do ponto de entrada na pele, ângulos sagital e axial relacionadas à hipotética inserção de um parafuso S2AI e comparadas às mesmas medidas obtidas em relação ao parafuso de ilíaco. Resultados O comprimento ósseo médio foi de 136,7 mm, maior diâmetro ósseo foi de 24,8 mm, o menor diâmetro ósseo de 19,7 mm e a distância do parafuso para a pele foi de 42,1 mm para o parafuso S2AI. Conclusão Os dados obtidos apresentam uma média da amostra que podem ser úteis na decisão da técnica cirúrgica no grupo estudado. Nível de evidência I; Estudo Diagnóstico (Investigação Anatômica).


RESUMEN Objetivo El uso de tornillos pediculares fue un marco para la cirugía moderna de la columna vertebral. Este tipo de fijación, debido a su biomecánica superior, dio mayor poder de fijación, mayor capacidad de resistir a las fuerzas de tracción y, por lo tanto, mayor estabilidad y menores tasas de pseudoartrosis. La fijación de la unión lumbosacra, incluso con el desarrollo de estos nuevos implantes, sigue siendo un desafío debido principalmente a las considerables tasas de pseudoartrosis. El uso de tornillos ilíacos soluciona el problema biomecánico. Sin embargo, su uso muestra altas tasas de problemas en la herida quirúrgica. El tornillo S2-Alar-Ilíaco (S2AI) vino como solución para estas complicaciones. La falta de estudios sobre los parámetros anatómicos y antropométricos en la población brasileña justifica el estudio realizado. Métodos Se analizaron 11 tomografías de cadera de hombres brasileños adultos por 4 evaluadores, considerando los lados derecho e izquierdo. En cada paciente se realizaron medidas de mayor y menor longitud ósea, mayor y menor diámetro óseo, distancia del punto de entrada en la piel, ángulos sagital y axial relacionados con la inserción hipotética de un tornillo S2AI y comparados a las mismas medidas obtenidas en relación al tornillo ilíaco. Resultados La longitud ósea promedio fue de 136,7 mm, el mayor diámetro óseo fue de 24,8 mm, el diámetro óseo menor de ١٩,٧ mm y la distancia del tornillo a la piel fue de 42,1 mm para el tornillo S2AI. Conclusiones Los datos obtenidos presentan un promedio de la muestra que puede ser útil en la decisión de la técnica quirúrgica en el grupo estudiado. Nivel de evidencia I; Estudios de Diagnósticos (Investigación Anatómica).


Subject(s)
Humans , Spinal Diseases , Anatomy , Lumbosacral Region
2.
Coluna/Columna ; 17(4): 313-316, Oct.-Dec. 2018. tab, graf
Article in English | LILACS | ID: biblio-975002

ABSTRACT

ABSTRACT Objective: Lumbosacral fixation presents problems in its arthrodesis, mainly due to pseudoarthrosis. Iliac screws minimize this problem, however, they show problems in the operative wound. The S2-Alar-iliac (S2AI) screw presents a lower rate of these complications. The anatomical differences between the populations and the sexes analyzed in the literature justify the study of the S2AI screw technique in Brazilian women. Methods: A total of 14 adult female CT scans were analyzed by 4 evaluators. Results: The mean bone length was 131.8 mm, the largest bone diameter was 22.6 mm, and the smallest bone diameter was 22.6 mm. Conclusions: The data presented are compatible with the literature and may assist spine surgeons in choosing the best implant and surgical technique. Level of Evidence I; Diagnostic Studies — Investigating a Diagnostic Test (anatomical investigation).


RESUMO Objetivos: A fixação lombossacra apresenta problemas na sua artrodese, devido principalmente à pseudoartrose. Os parafusos de ilíaco minimizam esse problema, contudo mostram problemas na ferida operatória. Já o parafuso de S2-Alar-Ilíaco (S2AI) apresenta menor índice dessas complicações. As diferenças anatômicas entre as populações e os sexos analisados na literatura justificam o estudo da técnica de parafuso de S2AI em mulheres brasileiras. Métodos: Foram analisadas 14 tomografias de mulheres adultas por quatro avaliadores. Resultados: O comprimento ósseo médio foi de 131,8 mm, maior diâmetro ósseo foi de 22,6 mm, o menor diâmetro ósseo de 22,6 mm. Conclusões: Os dados apresentados são compatíveis com a literatura e podem ajudar os cirurgiões de coluna na escolha do melhor implante e na técnica cirúrgica. Nível de Evidência I; Investigação de um exame para diagnóstico (investigação anatômica).


RESUMEN Objetivos: La fijación lumbosacra presenta problemas en la artrodesis, principalmente a causa de la pseudoartrosis. Los tornillos del ilíaco minimizan este problema, pero causan problemas en la herida quirúrgica. El tornillo S2-Alar-ilíaco (S2AI) muestra un menor índice de estas complicaciones. Las diferencias anatómicas entre las poblaciones y los sexos analizados en la literatura justifican el estudio de la técnica del tornillo S2AI en mujeres brasileñas. Métodos: Cuatro evaluadores analizaron 14 tomografías de mujeres adultas. Resultados: La longitud ósea media fue de 131,8 mm, el mayor diámetro fue de 22,6 mm, el menor diámetro óseo fue 22,6 mm. Conclusiones: Los datos presentados son compatibles con la literatura y pueden ayudar a los cirujanos de columna en la elección del mejor implante y técnica quirúrgica. Nivel de Evidencia I; Estudios de diagnósticos - Investigación de un examen para diagnóstico (investigación anatómica).


Subject(s)
Humans , Female , Bone Screws , Arthrodesis , Spine/surgery , Diagnostic Imaging , Magnetic Resonance Imaging
3.
Acta ortop. bras ; 20(2): 75-78, 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-622366

ABSTRACT

OBJETIVO: Estudo anatômico do áxis através de tomografia computadorizada (TC) em crianças de dois a dez anos de idade, mensurando a angulação das lâminas, espessura e comprimento de lâminas e pedículos e espessura da massa lateral. MÉTODOS: Estudou-se 64 TCs da coluna cervical de indivíduos com idades entre 24 e 120 meses, de ambos os sexos e sem deformidades cervicais. Correlacionaram-se as variáveis estudadas com os grupos etários e sexo dos pacientes. A análise estatística foi realizada por meio do teste t. RESULTADOS: Verificou-se que na faixa etária entre 24-48 meses, 5,5% das lâminas e 8,3% dos pedículos possuem espessura menores do que 3,5mm, espessura necessária para colocação de um parafuso. Entre 49-120 meses não há lâminas com espessuras menores do que 3,5mm e 1,2% dos pedículos possuem espessura menor do que 3,5mm. Em ambos os grupos etários não há comprimento de lâminas e pedículos menores do que 12 mm e massas laterais maiores do que 12 mm. CONCLUSÃO: A análise das dimensões obtidas no estudo permite, na maioria dos casos, a colocação de parafusos de 3,5mm nas lâminas e pedículos do áxis de crianças. Nível de Evidência II, Desenvolvimento de critérios diagnósticos em pacientes consecutivos.


OBJECTIVE: To carry out an anatomical study of the axis with the use of computed tomography (CT) in children aged from two to ten years, measuring the lamina angle, lamina and pedicle length and thickness, and lateral mass length. METHODS: Sixty-four CTs were studied from patients aged 24 to 120 months old, of both sexes and without any cervical anomaly. The measurements obtained were correlated with the data on age and sex of the patients. Statistical analysis was performed using the Students "t" tests. RESULTS: We found that within the age range 24-48 months, 5.5% of the lamina and 8.3% of the pedicles had thicknesses of less than 3.5mm, which is the minimum thickness needed for insertion of the screw. Between 49 and 120 months, there were no lamina thicknesses of less than 3.5mm, and 1.2% of the pedicle thicknesses were less than 3.5mm values. Neither of the age groups had any lamina and pedicle lengths of less than 12mm, or lateral mass lengths greater than 12mm. CONCLUSION: The analysis of the data obtained demonstrates that most of the time, is possible to use a 3.5mm pedicle screw in the laminas and pedicles of the axis in children. Level of Evidence: II, Development of diagnostic criteria in consecutive patients.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Axis, Cervical Vertebra/anatomy & histology , Bone Screws , Spine/anatomy & histology , Lamins , Spinal Fusion , Data Interpretation, Statistical , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL