Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Arq. bras. cardiol ; 105(3): 241-247, Sept. 2015. ilus, tab
Article in English | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: lil-761513

ABSTRACT

AbstractBackground:Predicting mortality in patients undergoing transcatheter aortic valve implantation (TAVI) remains a challenge.Objectives:To evaluate the performance of 5 risk scores for cardiac surgery in predicting the 30-day mortality among patients of the Brazilian Registry of TAVI.Methods:The Brazilian Multicenter Registry prospectively enrolled 418 patients undergoing TAVI in 18 centers between 2008 and 2013. The 30-day mortality risk was calculated using the following surgical scores: the logistic EuroSCORE I (ESI), EuroSCORE II (ESII), Society of Thoracic Surgeons (STS) score, Ambler score (AS) and Guaragna score (GS). The performance of the risk scores was evaluated in terms of their calibration (Hosmer–Lemeshow test) and discrimination [area under the receiver–operating characteristic curve (AUC)].Results:The mean age was 81.5 ± 7.7 years. The CoreValve (Medtronic) was used in 86.1% of the cohort, and the transfemoral approach was used in 96.2%. The observed 30-day mortality was 9.1%. The 30-day mortality predicted by the scores was as follows: ESI, 20.2 ± 13.8%; ESII, 6.5 ± 13.8%; STS score, 14.7 ± 4.4%; AS, 7.0 ± 3.8%; GS, 17.3 ± 10.8%. Using AUC, none of the tested scores could accurately predict the 30-day mortality. AUC for the scores was as follows: 0.58 [95% confidence interval (CI): 0.49 to 0.68, p = 0.09] for ESI; 0.54 (95% CI: 0.44 to 0.64, p = 0.42) for ESII; 0.57 (95% CI: 0.47 to 0.67, p = 0.16) for AS; 0.48 (95% IC: 0.38 to 0.57, p = 0.68) for STS score; and 0.52 (95% CI: 0.42 to 0.62, p = 0.64) for GS. The Hosmer–Lemeshow test indicated acceptable calibration for all scores (p > 0.05).Conclusions:In this real world Brazilian registry, the surgical risk scores were inaccurate in predicting mortality after TAVI. Risk models specifically developed for TAVI are required.


ResumoFundamento:Ainda é desafiador prever a mortalidade de pacientes que se submetem ao TAVI (sigla do inglês Transcatheter Aortic Valve Implantation).Objetivos:Avaliar o desempenho de cinco escores de risco para cirurgia cardíaca em prever mortalidade em 30 dias de pacientes inscritos no Registro Brasileiro de TAVI.Métodos:O Registro Multicêntrico Brasileiro inscreveu prospectivamente 418 pacientes submetidos ao TAVI em 18 centros entre 2008 e 2013. Os seguintes escores cirúrgicos foram usados para calcular o risco de mortalidade no período de 30 dias: EuroSCORE I (ESI) logístico, EuroSCORE II (ESII), STS Score (STS), Ambler Score (AS) e Guaragna Score (GS). O desempenho dos escores de risco foram avaliados através de sua calibração (teste Hosmer-Lemeshow) e discriminação [área sob a curva (AUC) do inglês receiver-operating characteristic curve)].Resultados:A idade média foi de 81,5 ± 7,7 anos. A prótese aórtica CoreValve (Medtronic) foi usada em 86,1% da coorte e a abordagem transfemural usada em 96,2%. A mortalidade observada no período de 30 dias foi de 9,1%. A mortalidade no período de 30 dias prevista pelos escores foi: ESI, 20,2 ± 13,8%; ESII, 6,5 ± 13,8%; STS, 14,7 ± 4,4%; AS, 7,0 ± 3,8%; GS, 17,3 ± 10,8%. Nenhum dos escores testados com a AUC foi capaz de prever a mortalidade no período de 30 dias de forma precisa. As AUC para os escores foram: 0,58 [95% de intervalo de confiança (IC): 0,49 a 0,68, p = 0,09] para ESI; 0,54 (IC de 95%: 0,44 a 0,64, p = 0,42) para ESII; 0,57 (IC de 95%: 0,47 a 0,67, p = 0,16) para AS; 0,48 (IC de 95%: 0,38 a 0,57, p = 0,68) para STS e 0,52 (IC de 95%: 0,42 a 0,62, p = 0,64) para GS. O teste Hosmer-Lemeshow indicou uma calibração aceitável para todos os escores (p > 0,05).Conclusões:Neste registro brasileiro de mundo real, os escores de risco cirúrgico foram imprecisos para prever a mortalidade após o TAVI. São necessários modelos de risco desenvolvidos especificamente para o TAVI.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Risk Assessment/methods , Transcatheter Aortic Valve Replacement/mortality , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Brazil , Calibration , Epidemiologic Methods , Reference Values , Reproducibility of Results , Time Factors
2.
Arq. bras. cardiol ; 99(6): 1129-1134, dez. 2012. tab
Article in Portuguese | LILACS | ID: lil-662373

ABSTRACT

FUNDAMENTO: A exposição ao meio de contraste radiográfico pode causar comprometimento agudo da função renal. Há evidências limitadas e conflitantes de que a hidratação com bicarbonato de sódio previne a Nefropatia Induzida por Contraste (NIC) em pacientes submetidos a cateterismo cardíaco. OBJETIVO: O presente estudo teve como objetivo determinar se o bicarbonato de sódio é superior à hidratação com soro fisiológico para evitar a nefropatia em pacientes de risco submetidos a cateterismo cardíaco. MÉTODOS: Trezentos e um pacientes submetidos a intervenção coronariana percutânea ou angiografia coronariana com creatinina sérica > 1,2 mg/dL ou Taxa de Filtração Glomerular (TFG) < 50 mL/min, foram randomizados para receber hidratação com bicarbonato de sódio a partir de 1 hora antes do procedimento, e 6 horas após o procedimento, ou hidratação com solução salina a 0,9%. A NIC foi definida como um aumento de 0,5 mg/dL na creatinina em 48h. RESULTADOS: Dezoito pacientes (5,9%) desenvolveram nefropatia induzida por contraste: 9 pacientes no grupo do bicarbonato (6,1%) e 9 pacientes no grupo da solução salina (6,0%), p = 0,97. A variação na creatinina sérica foi semelhante em ambos os grupos, 0,01 ± 0,26 mg/dL no grupo do bicarbonato, e 0,01 ± 0,35 mg/dL no grupo da solução salina, p = 0,9. Não foi observada diferença estatística entre a alteração na taxa de filtração glomerular (0,89 ± 9 mL/ min vs. 2,29 ± 10 mL/min, p = 0,2, grupo do bicarbonato e grupo da solução salina, respectivamente). CONCLUSÃO: A hidratação com bicarbonato de sódio não foi superior ao soro fisiológico na prevenção a nefropatia induzida pelo contraste, em pacientes de risco submetidos a cateterismo cardíaco.


BACKGROUND: Radiographic contrast media exposition can cause acute renal function impairment. There is limited and conflicting evidence that hydration with sodium bicarbonate prevents contrast-induced nephropathy (CIN) in patients undergoing cardiac catheterization. OBJECTIVE: The present study was aimed at determining whether sodium bicarbonate is superior to hydration with saline to prevent nephropathy in patients at risk undergoing cardiac catheterization. METHODS: Three hundred and one patients undergoing coronary angiography or percutaneous coronary intervention with serum creatinine > 1.2mg/dL or glomerular filtration rate (GFR) < 50ml/min were randomized to receive hydration with sodium bicarbonate starting 1 hour before the procedure and 6 hours after the procedure, or hydration with 0.9% saline. CIN was defined as an increase of 0.5mg/dL in creatinine in 48h RESULTS: Eighteen patients (5.9%) developed contrast induced nephropathy: 9 patients in the bicarbonate group (6.1%) and 9 patients in the saline group (6.0%), p = 0.97. The change in serum creatinine was similar in both groups, 0.01 ± 0.26 mg/dL in the bicarbonate group and 0.01 ± 0.35 mg/dL in the saline group, p = 0.9. No statistical difference was observed between the change in glomerular filtration rate (0.89 ± 9 ml/min vs. 2.29 ± 10 ml/min, p = 0.2 bicarbonate group and saline group, respectively). CONCLUSION: Hydration with sodium bicarbonate was not superior to saline to prevent contrast media induced nephropathy in patients at risk undergoing cardiac catheterization.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Cardiac Catheterization , Contrast Media/adverse effects , Fluid Therapy/methods , Kidney Diseases/chemically induced , Kidney Diseases/prevention & control , Sodium Bicarbonate/therapeutic use , Creatinine/blood , Glomerular Filtration Rate/drug effects , Risk Factors , Statistics, Nonparametric , Sodium Chloride/therapeutic use , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL