1.
Journal of Agricultural Medicine & Community Health ; : 220-228, 2022.
Article in English | WPRIM | ID: wpr-968927

ABSTRACT

Objective@#glucometer is one of POCT(point-of-care testing) devices used by EMS. Accurate measurement value is important for patient decision making. Quality control is necessary for this, but most EMS are still using glucometer without quality control it. Therefore, management status and quality control status of glucometers used by 119 paramedics waswere investigated. @*Methods@#6 and 8 of glucometers and blood glucose test strips were submitted from 4 safety centers in 2010 and 8 safety centers in 2012, respectively. Glucometers submitted by local safety centers were analyzed in 2010 and 2012. The control glucometer, which was well managed at A University Hospital, was assumed to be accurate for at blood glucose measurement. Glucose values of various quality control materials control solutions were measured and analyzed using linear regression and Pearson’s correlation test. Error rates were obtained via error tolerance range required by the 2011 ISO(International Organization for Standardization) guideline. For statistics, Excel and MedCalC programs were used. @*Results@#mong 14 safety centers in the region, 4 centers(28.5%) in 2010 and 8 centers(57.1%) in 2012 submitted 6 and 8 glucometers. In the first evaluation in 2010, 2 out of 6(33.3%) glucometers were untestable due to error, and 45 out of 6(66.683.3%) blood glucose test strips' validity were expired. In the second evaluation in 2012, 1 out of 8(13.5%) glucometers were untestable due to lack of battery, and 2 out of 8(25%) blood glucose test strips' validity were expired. All correlation coefficients were above 0.989 in 2010 and above 0.997 in 2012. Error rates were generally high when using expired blood glucose test strips. @*Conclusion@#Among 119 paramedics’ guideline, quantity and operation status of POCT devices are well managed, but quality control is not. Therefore, it is necessary to add management status and quality control status of POCT devices to the EMS’ field work guideline.

2.
Journal of the Korean Pediatric Society ; : 1094-1100, 1993.
Article in Korean | WPRIM | ID: wpr-62464

ABSTRACT

To evaluate the relationship between spontancous diuresis and improvement of pulmonary function in respiratory distress syndrome, 15 premature neonates requiring mechanical ventilation for RDS, who admitted in NICU of Wonkwang University Hospital from January 1990 to June 1992, were studied. The results were as follows (results are mean+/-SEM) 1) Mean birth weight of study infants was 1.82+/-0.08Kg, and mean gestational age was 32.80+/-0.54 weeks. 2) The onset of diuresis occured at a mean age of 29.1+/-2.48 hours with maximum diuresis at a mean age of 41.9+/-1.8 hours 3) Mean urine output increased from 2.25+/-0.43ml/Kg/hr at the stage of pre 12 hours-onset of diuresis (p<0.001), then decreased 3.5+/-0.2ml/Kg/hr at the stage of after maximum diuresis (p<0.05). 4) After maximum diuresis, inspired oxygen gradient, peak inflating pressure, peak end expiratory pressure, mean airway pressure, and respiratory rate were decreased significantly (p<0.05), and alveolar-arterial oxygen gradient was decreased more significantly (p<0,01). So, We conclude that the pulmonary function was rapidly improving after maximum diuresis and these changes reflect the general principle used in ventilatory management of infants with RDS.


Subject(s)
Humans , Infant , Infant, Newborn , Birth Weight , Diuresis , Gestational Age , Oxygen , Respiration, Artificial , Respiratory Rate
SELECTION OF CITATIONS
SEARCH DETAIL