Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
International Neurourology Journal ; : S82-90, 2023.
Article in English | WPRIM | ID: wpr-1000565

ABSTRACT

Purpose@#The development of optics-based wearables for bladder volume monitoring has emerged as a significant topic in recent years. Given the innovative nature of this technology, there is currently no bladder phantom available to effectively validate these devices against more established gold standards, such as ultrasound. In this study, we showcase and demonstrate the performance of our hybrid bladder phantom by using an optical device and making comparisons with ultrasound. @*Methods@#A series of validation tests, including phantom repeatability, ultrasound scanning, and an optical test, were performed. A near-infrared optical device was utilized to conduct diffuse optical spectroscopy (DOS). Machine learning models were employed to construct predictive models of volume using optical signals. @*Results@#The size and position of an embedded balloon, serving as an analog for the bladder, were shown to be consistent when infused with 100 mL to 350 mL of water during repeatability testing. For DOS data, we present 7 types of machine learningbased models based on different optical signals. The 2 best-performing models demonstrated an average absolute volume error ranging from 12.7 mL to 19.0 mL. @*Conclusions@#In this study, we introduced a hybrid bladder phantom designed for the validation of near-infrared spectroscopy-based bladder monitoring devices in comparison with ultrasound techniques. By offering a reproducible and robust validation tool, we aim to support the advancement of next-generation optical wearables for bladder volume monitoring.

2.
International Neurourology Journal ; : S27-33, 2023.
Article in English | WPRIM | ID: wpr-1000558

ABSTRACT

Purpose@#Current guidelines recommend clean intermittent catheterization (CIC) at regular time intervals for patients with spinal cord injuries; however, many patients experience difficulties. Performing time-based CIC outside the home is a significant burden for patients. In this study, we aimed to overcome the limitations of the current guidelines by developing a digital device to monitor bladder urine volume in real-time. @*Methods@#The optode sensor is a near-infrared spectroscopy (NIRS)-based wearable device intended to be attached to the skin of the lower abdomen where the bladder is located. The sensor’s primary function is to detect changes in urine volume within the bladder. An in vitro study was conducted using a bladder phantom that mimicked the optical properties of the lower abdomen. To validate the data in the human body at the proof-of-concept level, one volunteer attached the device to the lower abdomen to measure the light intensity between the first voiding and immediately before the second voiding. @*Results@#The degree of attenuation at the maximum test volume was equivalent across experiments, and the optode sensor with multiplex measurements demonstrated robust performance for patient diversity. Moreover, the symmetric feature of the matrix was deemed a potential parameter for identifying the accuracy of sensor localization in a deep-learning model. The validated feasibility of the sensor showed almost the same results as an ultrasound scanner, which is routinely used in the clinical field. @*Conclusions@#The optode sensor of the NIRS-based wearable device can measure the urine volume in the bladder in real-time.

SELECTION OF CITATIONS
SEARCH DETAIL