Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Year range
1.
The Journal of Korean Knee Society ; : 283-288, 2016.
Article in English | WPRIM | ID: wpr-759243

ABSTRACT

PURPOSE: The purpose was to compare the accuracy of Miniaci method using picture archiving and communication system (PACS) with a cable method in high tibial osteotomy (HTO). MATERIALS AND METHODS: This study analyzed 47 patients (52 knees) with varus deformity and medial osteoarthritis. From 2007 to 2013, patients underwent HTO using either a cable method (20 knees) or Miniaci method based on a PACS image (32 knees). In the cable method, the 62.5% point of the mediolateral tibial plateau width was located using an electrocautery cord under fluoroscopy (cable group). The Miniaci method used preoperative radiographs to shift the weight bearing axis (PACS group). Full-length lower limb radiographs obtained preoperatively and at the sixth postoperative week were used to compare the percentage of crossing point of the weight bearing line on the tibial plateau with respect to the medial border. RESULTS: The weight bearing line on the tibial plateau was corrected from a preoperative 11.0±7.0% to a postoperative 47.2±7.4% in the cable group and from 12.7±4.9% to 59.5±5.3% in the PACS group. The mechanical femorotibial angle was corrected from varus 8.9±3.7° to valgus 0.3±4.0° in the cable group and from varus 9.0±3.3° to valgus 2.9±2.6° in the PACS group. CONCLUSIONS: In HTO, correction based on the Miniaci method using a PACS was more accurate than correction using the cable method.


Subject(s)
Humans , Congenital Abnormalities , Electrocoagulation , Fluoroscopy , Knee , Lower Extremity , Methods , Osteoarthritis , Osteotomy , Planning Techniques , Weight-Bearing
2.
Clinics in Orthopedic Surgery ; : 185-190, 2015.
Article in English | WPRIM | ID: wpr-69222

ABSTRACT

BACKGROUND: The purpose of this study was to compare the results of Aescula and TomoFix plates used for biplanar open wedge high tibial osteotomy in medial osteoarthritis of the knee joint with varus deformity. METHODS: A consecutive series of 50 cases of biplanar open wedge high tibial osteotomy were evaluated retrospectively. Group A contained 25 cases treated by using the Aescula plate, and group T contained 25 cases treated by using the TomoFix plate. Full weight-bearing was permitted at 6 weeks after surgery in group A and at 2 weeks in group T. Clinical evaluations were performed at the final follow-up by using postoperative knee scores and functional scores. Radiographic analysis included postoperative mechanical femur-tibia angle, change in posterior tibial slope angle, and complications related to implants. The mean follow-up periods were 30 months in group A and 26 months in group T. RESULTS: The knee and functional scores were improved at the final follow-up in both groups (p 0.05). An acceptable correction angle was obtained in 52% of group A and in 84% of group T (p = 0.015). Change in posterior tibial slope angle was larger in group A than in group T (p < 0.001), showing better maintenance of posterior tibial slope in group T. In group A, there were 3 cases of screw loosening and 4 cases of delayed union. In addition, there were residual varus deformities in 7 cases (6 in group A and 1 in group T). CONCLUSIONS: This study shows that firm fixation using a TomoFix plate for open wedge high tibial osteotomy produces better radiologic results and a low complication rate than those of the Aescula spacer plate.


Subject(s)
Humans , Bone Plates , Equipment Design , Osteoarthritis, Knee/surgery , Osteotomy/methods , Retrospective Studies , Tibia/surgery
3.
The Journal of Korean Knee Society ; : 43-48, 2015.
Article in English | WPRIM | ID: wpr-759161

ABSTRACT

PURPOSE: This study evaluated mid-term results of anterior cruciate ligament (ACL) reconstruction using the PINN-ACL CrossPin system that allowed for short graft fixation. MATERIALS AND METHODS: Forty-three patients underwent single-bundle ACL reconstruction with a 4-strand semitendinosus tendon graft using the PINN-ACL CrossPin system. Femoral fixation was done using the PINN-ACL CrossPin system, and the tibial side was fixed with post-tie and a bioabsorbable interference screw. The mean follow-up period was 50 months. Evaluation was done using the Lachman test, pivot-shift test, International Knee Documentation Committee (IKDC) score and grade. Anterior displacement was assessed. RESULTS: There was improvement in the Lachman test and pivot-shift test at final follow-up, form grade II (n=40) or III (n=3) to grade I (n=3) or 0 (n=40) and from grade I (n=20) or II (n=10) to grade I (n=8) or 0 (n=22), respectively. The mean IKDC score was 88.7, and grade A and B were 93.0% at final follow-up. Side-to-side difference was improved from 6.7 mm to 2.1 mm at final follow-up. Complications occurred in 3 patients, a re-ruptured due to trauma at 2 years after surgery and a deep infection and a superficial infection. CONCLUSIONS: The mid-term follow-up results of ACL reconstruction with the PINN-ACL CrossPin system were satisfactory. The PINN-ACL CrossPin can be considered as a useful instrument for short graft fixation.


Subject(s)
Humans , Anterior Cruciate Ligament , Anterior Cruciate Ligament Reconstruction , Follow-Up Studies , Knee , Tendons , Transplants
4.
Clinics in Orthopedic Surgery ; : 310-317, 2015.
Article in English | WPRIM | ID: wpr-127326

ABSTRACT

BACKGROUND: The purpose of this study was to determine the degree of infection control and postoperative function for new articulating metal-on-cement spacer. METHODS: A retrospective study of 19 patients (20 cases), who underwent a two-stage revision arthroplasty using mobile cement prosthesis, were followed for a minimum of 2 years. This series consisted of 16 women and 3 men, having an overall mean age of 71 years. During the first stage of revision, the femoral implant and all the adherent cement was removed, after which it was autoclaved before replacement. The tibial component was removed and a doughy state, antibiotic-impregnated cement was inserted on the tibial side. To achieve joint congruency, intraoperative molding was performed by flexing and extending the knee joint. Each patient was evaluated clinically and radiologically. The clinical assessments included range of motion, and the patients were scored as per the Hospital for Special Surgery (HSS) and Knee Society (KS) criteria. RESULTS: The mean range of knee joint motion was 70degrees prior to the first stage operation and 72degrees prior to the second stage revision arthroplasty; following revision arthroplasty, it was 113degrees at the final follow-up. The mean HSS score and KS knee and function scores were 86, 82, and 54, respectively, at the final follow-up. The success rate in terms of infection eradication was 95% (19/20 knees). No patient experienced soft tissue contracture requiring a quadriceps snip. CONCLUSIONS: This novel technique provides excellent radiological and clinical outcomes. It offers a high surface area of antibiotic-impregnated cement, a good range of motion between first and second stage revision surgery for the treatment of chronic infection after total knee arthroplasty, and is of a reasonable cost.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Anti-Bacterial Agents/administration & dosage , Arthroplasty, Replacement, Knee/adverse effects , Bone Cements/therapeutic use , Prosthesis-Related Infections/surgery , Range of Motion, Articular/physiology , Reoperation/instrumentation , Retrospective Studies , Treatment Outcome
5.
Clinics in Orthopedic Surgery ; : 97-103, 2015.
Article in English | WPRIM | ID: wpr-119050

ABSTRACT

BACKGROUND: In the present study, we aimed to compare clinical and radiographic outcomes between hook plate fixation and coracoclavicular (CC) ligament reconstruction for the treatment of acute unstable acromioclavicular (AC) joint dislocation. METHODS: Forty-two patients who underwent surgery for an unstable acute dislocation of the AC joint were included. We divided them into two groups according to the treatment modality: internal fixation with a hook plate (group I, 24 cases) or CC ligament reconstruction (group II, 18 cases). We evaluated the clinical outcomes using a visual analog scale (VAS) for pain and Constant-Murley score, and assessed the radiographic outcomes based on the reduction and loss of CC distance on preoperative, postoperative, and final follow-up plain radiographs. RESULTS: The mean VAS scores at the final follow-up were 1.6 +/- 1.5 and 1.3 +/- 1.3 in groups I and II, respectively, which were not significantly different. The mean Constant-Murley scores were 90.2 +/- 9.9 and 89.2 +/- 3.5 in groups I and II, respectively, which were also not significantly different. The AC joints were well reduced in both groups, whereas CC distance improved from a mean of 215.7% +/- 50.9% preoperatively to 106.1% +/- 10.2% at the final follow-up in group I, and from 239.9% +/- 59.2% preoperatively to 133.6% +/- 36.7% at the final follow-up in group II. The improvement in group I was significantly superior to that in group II (p < 0.001). Furthermore, subluxation was not observed in any case in group I, but was noted in six cases (33%) in group II. Erosions of the acromion undersurface were observed in 9 cases in group I. CONCLUSIONS: In cases of acute unstable AC joint dislocation, hook plate fixation and CC ligament reconstruction yield comparable satisfactory clinical outcomes. However, radiographic outcomes based on the maintenance of reduction indicate that hook plate fixation is a better treatment option.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Acromioclavicular Joint/injuries , Acute Disease , Arthroscopy , Bone Plates , Joint Dislocations/diagnostic imaging , Ligaments, Articular/surgery , Retrospective Studies , Treatment Outcome
6.
Clinics in Orthopedic Surgery ; : 312-317, 2014.
Article in English | WPRIM | ID: wpr-104724

ABSTRACT

BACKGROUND: To determine relative fixation strengths of a single lateral locking plate, a double construct of a locking plate, and a tibial nail used in treatment of proximal tibial extra-articular fractures. METHODS: Three groups of composite tibial synthetic bones consisting of 5 specimens per group were included: lateral plating (LP) using a locking compression plate-proximal lateral tibia (LCP-PLT), double plating (DP) using a LCP-PLT and a locking compression plate-medial proximal tibia, and intramedullary nailing (IN) using an expert tibial nail. To simulate a comminuted fracture model, a gap osteotomy measuring 1 cm was created 8 cm below the knee joint. For each tibia, a minimal preload of 100 N was applied before loading to failure. A vertical load was applied at 25 mm/min until tibial failure. RESULTS: Under axial loading, fixation strength of DP (14,387.3 N; standard deviation [SD], 1,852.1) was 17.5% greater than that of LP (12,249.3 N; SD, 1,371.6), and 60% less than that of IN (22,879.6 N; SD, 1,578.8; p < 0.001, Kruskal-Wallis test). For ultimate displacement under axial loading, similar results were observed for LP (5.74 mm; SD, 1.01) and DP (4.45 mm; SD, 0.96), with a larger displacement for IN (5.84 mm; SD, 0.99). The median stiffness values were 2,308.7 N/mm (range, 2,147.5 to 2,521.4 N/mm; SD, 165.42) for the LP group, 4,128.2 N/mm (range, 3,028.1 to 4,831.0 N/mm; SD, 832.88) for the DP group, and 5,517.5 N/mm (range, 3,933.1 to 7,078.2 N/mm; SD, 1,296.19) for the IN group. CONCLUSIONS: During biomechanical testing of a simulated comminuted proximal tibial fracture model, the DP proved to be stronger than the LP in terms of ultimate strength. IN proved to be the strongest; however, for minimally invasive osteosynthesis, which may be technically difficult to perform using a nail, the performance of the DP construct may lend credence to the additional use of a medial locking plate.


Subject(s)
Humans , Biomechanical Phenomena , Bone Nails , Bone Plates , Fracture Fixation, Internal/instrumentation , Fractures, Comminuted/physiopathology , Models, Anatomic , Tibial Fractures/physiopathology
7.
Journal of the Korean Society for Surgery of the Hand ; : 193-196, 2010.
Article in Korean | WPRIM | ID: wpr-52341

ABSTRACT

A 50-year-old man who had a gout presented with a difficulty in flexing his left small finger. Operative exploration revealed a rupture of the deep flexor tendons because of gouty tophus on flexor tendon sheath infiltration. The patient underwent single stage tendon graft using the palmaris longus tendon, resulting in satisfactory results. Gouty tophus infiltration should be considered as one of causes of flexor tendon rupture of the fingers in patients with a long history of gout.


Subject(s)
Humans , Middle Aged , Fingers , Gout , Rupture , Tendons , Transplants
SELECTION OF CITATIONS
SEARCH DETAIL