1.
Korean Journal of Medicine ; : 87-91, 2014.
Article in Korean | WPRIM | ID: wpr-69087

ABSTRACT

Patients with tracheostomies requiring prolonged home mechanical ventilation are increasing in number rapidly. A tracheoesophageal fistula is a relatively unusual complication, but this case resulted in a fatal outcome. We describe a tracheoesophageal fistula with tracheal dilation in a 72-year-old female who had a prolonged tracheostomy and nasogastric tube, using a home mechanical ventilator. On enhanced CT images, the tracheostomy tube was well located within the trachea with no abnormal finding. However, chest enhanced CT images obtained 5 months later showed marked circumferential wall thickening of the trachea with tiny ulceration, a markedly increased diameter of the tracheal lumen, and a tracheoesophageal fistula. In patients using home mechanical ventilators, the location and cuff pressure of the tracheostomy tube and the nasogastric tube should be evaluated routinely.


Subject(s)
Aged , Female , Humans , Dilatation , Fatal Outcome , Respiration, Artificial , Thorax , Trachea , Tracheoesophageal Fistula , Tracheostomy , Ulcer , Ventilators, Mechanical