Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Journal of Peking University(Health Sciences) ; (6): 934-938, 2023.
Article in Chinese | WPRIM | ID: wpr-1010152

ABSTRACT

OBJECTIVE@#Agar dilution method (ADM) was used as the golden standard to evaluate the consistency of Epsilometer test (E-test) in detecting the sensitivity of Helicobacter pylori (H. pylori) to metronidazole.@*METHODS@#From August 2018 to July 2020, patients with H. pylori infection treated for the first time in Peking University Third Hospital for gastroscopy due to dyspepsia were included in this study. Gastric mucosas were taken from the patients with H. pylori infection. H. pylori culture was performed. Both the ADM and E-test were applied to the antibiotic susceptibility of H. pylori to metro-nidazole, and the consistency and correlation between the two methods were validated.@*RESULTS@#In the study, 105 clinical isolates of H. pylori were successfully cultured, and the minimum inhibitory concentration ≥ 8 mg/L was defined as drug resistance. Both ADM and the E-test showed high resistance rates to metronidazole, 64.8% and 62.9%, respectively. Among them, 66 drug-resistant strains were detected by ADM and E-test, and 37 were sensitive strains, so the consistency rate was 98.1%. Two strains were evaluated as drug resistance by ADM, but sensitive by the E-test, with a very major error rate of 1.9%. There was zero strain sensitive according to ADM but assessed as resistant by the E-test, so the major error rate was 0%. Taking ADM as the gold standard, the sensitivity of E-test in the detection of metronidazole susceptibility was 97.1% (95%CI: 0.888-0.995), and the specificity was 100% (95%CI: 0.883-1.000). Cohen's kappa analysis showed substantial agreement, and kappa coefficient was 0.959 (95%CI: 0.902-1.016, P < 0.001). Spearmans correlation analysis confirmed this correlation was significant (r=0.807, P < 0.001). The consistency evaluation of Bland-Altman method indicated that it was good, and there was no measured value outside the consistency interval. In this study, cost analysis, including materials and labor, showed a 32.2% higher cost per analyte for ADM as compared with the E-test (356.6 yuan vs. 269.8 yuan).@*CONCLUSION@#The susceptibility test of H. pylori to metronidazole by E-test presents better agreement with ADM. Because it is less expensive, less labor intensive, and more rapid, it is an easy and reliable method for H. pylori susceptibility testing.


Subject(s)
Humans , Metronidazole/therapeutic use , Helicobacter pylori , Agar/therapeutic use , Disk Diffusion Antimicrobial Tests , Microbial Sensitivity Tests , Helicobacter Infections/drug therapy , Anti-Bacterial Agents/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL