Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Rev. med. interna Guatem ; 21(1): 13-15, ene.-abr. 2017. gráficos
Article in Spanish | LILACS | ID: biblio-995107

ABSTRACT

OBJETIVO: determinar si existe correlación entre las variables índices PaO2/FiO2 y SpO2/FiO2 de pacientes con Síndrome de Distres Respiratorio Agudo -SDRA- en la Unidad de Terapia Intensiva de Adultos del Hospital General de Enfermedades del Instituto Guatemalteco de Seguridad Social. MÉTODOS: estudio observacional, prospectivo, longitudinal y analítico durante el periodo de enero del 2011 a septiembre del 2013, donde se incluyeron a 52 pacientes con criterios clínicos y gasométricos de SDRA. Las variables primarias fueron PaO2, SpO2, FiO2, las cuales determinan los índices PaO2/FiO2 y SpO2/FiO2. Las variables cuantitativas se presentan pro medio de una medida de tendencia central (media) y una medida de dispersión (desviación estándar). Se utilizó un nivel de confiabilidad del 95%, para prueba de hipótesis de una proporción. El análisis de correlación para medir la fuerza de la relación entre los índices PaO2/FiO2 y SpO2/FiO2 a través del coeficiente de Correlación de Pearson. RESULTADOS: se observa buena correlación, siendo esta positiva. De acuerdo a las observaciones realizadas, se observa una correlación lineal positiva (r = 0.98, p<0.01). CONCLUSIONES: el Índice SpO2/FiO2 puede utilizarse alternativamente al índice PaO2/FiO2 en el monitoreo no invasivo respiratorio de los pacientes con SDRA...(AU)


OBJETIVE: Primary endpoint was to determine if it does exists a correlation between the PaO2/ FiO2 ratio and SpO2/FiO2 ratio in patients with Acute Respiratory Distress Syndrome (ARDS), who were admitted to the Intensive Care Unit at Hospital General de Enfermedades del Instituto Guatemalteco de Seguridad Social. METHODS: We conducted a single-center, observational, prospective, longitudinal and analytical study from January 2011 to September 2013, this study included 52 critically ill patients, all of them met clinical and arterial blood gas criteria for ARDS. We review primary variables like PaO2, SpO2, FiO2, to stablish the paO2/FiO2 and SpO2/FiO2 ratio. Continuos variables were reported as means with standard deviations. The hazard ratio and its 95% confidence intervals were estimated. Pearson correlation coeficiente was use to measure of the strenght between the PaO2/FiO2 y SpO2/FiO2 ratio. RESULTS There is a good correlation, being this positive. According to the observations, we find a positive lineal correlation. (r = 0.98, p<0.01). CONCLUSIONS SPO2/FIO2 ratio can be use as an alternative of paO2/FiO2 ratio for non invasive monitoring in patients with Acute Respiratory Distress Syndrome...(AU)


Subject(s)
Humans , Male , Adult , Middle Aged , Aged , Aged, 80 and over , Respiration, Artificial/instrumentation , Respiratory Distress Syndrome/complications , Guatemala , Hypoxia/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL