Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
J. appl. oral sci ; 16(5): 355-359, Sept.-Oct. 2008. ilus, tab
Article in English | LILACS | ID: lil-495141

ABSTRACT

This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35 percent hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1 percent significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38±0.66ºC). The LED unit produced the lowest temperature increase (0.29±0.13ºC); but there was no significant difference between LED unit and LED-laser system (0.35±0.15ºC) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41±0.64ºC), and LED-laser system the lowest (0.33±0.12ºC); however, there was no difference between LED-laser system and LED unit (0.44±0.11ºC). LED and LED-laser ...


Subject(s)
Humans , Body Temperature , Dental Pulp/physiology , Light/adverse effects , Tooth Bleaching/adverse effects , Curing Lights, Dental , Halogens , Hydrogen Peroxide/radiation effects , Incisor , Lasers , Oxidants/radiation effects , Semiconductors
2.
Rev. bras. odontol ; 63(1/2): 40-44, 2006.
Article in Portuguese | LILACS, BBO | ID: lil-438453

ABSTRACT

Este trabalho faz um estudo comparativo entre as Escolas Filosóficas de Oclusão. Compara o crescimento e desenvolvimento dos conhecimentos. Trata-se de um assunto complexo, mas o profissional deve se interessar para estar apto a tratar o paciente como um todo. O sistema estomatognático deve ser respeitado, ressaltando a necessidade da harmonia na mastigação. A escola "Liberdade em Cêntrica" condiz melhor com os estudos feitos e com a vivência clínica, ficando comprovada sua total eficiência pelos muitos benefícios que traz


Subject(s)
Dental Occlusion , Philosophy, Dental
SELECTION OF CITATIONS
SEARCH DETAIL