Rev. venez. cir. ortop. traumatol ; 54(2): 53-61, dic. 2022. ilus
Article in Spanish | LILACS, LIVECS | ID: biblio-1516086

ABSTRACT

La Impresión 3D es una tecnología emergente utilizada cada vez más en medicina. En los países en vías de desarrollo, donde las fracturas por motocicletas y automóviles se encuentran en aumento, la disponibilidad de fijadores externos para el manejo de fracturas abiertas es un problema frecuente. La impresión 3D puede ser una alternativa económica e igualmente confiable a los dispositivos tradicionales elaborados con acero o titanio. El objetivo de este trabajo es mostrar la experiencia con el uso de Impresión 3D y su aplicación en el manejo clínico de fracturas abiertas diafisiarias de tibia. Se realizó un estudio pre-experimental y prospectivo. Se incluyeron 14 pacientes con fracturas de tibia AO/ASIF 42A, 42B y 42C tratados con un fijador externo con rótulas elaboradas con Impresión 3D como medida de Control de Daños en Ortopedia desde su ingreso hasta su resolución definitiva. Todos los pacientes fueron de sexo masculino, con un promedio de edad 23,16 años con 50% entre 20-23 años. Las fracturas fueron 42,85% tipo 42A, 37,71% 42B y 21,42% 42C. El 78,57% de las fracturas fueron ocasionadas por motocicletas: 57,14% grado II según Gustilo y Anderson, un 28,57% grado III y 14,28% grado I. El 37,71% eran politraumatizados. Ninguno de los pacientes presentó complicaciones como pérdida de la reducción, aflojamiento de las rótulas, ruptura o fatiga de las rótulas ni fatiga de la barra. La impresión 3D demostró ser una herramienta y alternativa útil en el manejo agudo de fracturas abiertas diafisiarias de tibia(AU)


3D Printing is an emerging technology used more and more in medicine. In developing countries, where motorcycle and automobile fractures are on the rise, the availability of external fixators for the management of open fractures is a frequent problem. 3D printing can be a cheap and equally reliable alternative to traditional devices made of steel or titanium. The objective of this work is to show the experience with the use of 3D Printing and its application in the clinical management of open diaphyseal fractures of the tibia. A pre-experimental and prospective study was made. 14 patients with AO/ASIF tibia fractures 42A, 42B and 42C treated with an external fixator with 3D-printed ball-caps as a Damage Control measure in Orthopedics from admission to final resolution were included. All patients were male, with an average age of 23,16 years, 50% between 20-23 years. The fractures were 42,85% type 42A, 37,71% 42B and 21,42% 42C. 78,57% of the fractures were caused by motorcycles: 57,14% grade II according to Gustilo and Anderson, 28,57% grade III and 14.28% grade I. 37,71% were polytraumatized. None of the patients had complications such as loss of reduction, loosening of the patellas, rupture or fatigue of the patellas, or rod fatigue. 3D printing proved to be a useful tool and alternative in the acute management of open diaphyseal fractures of the tibia(AU)


Subject(s)
Humans , Male , Female , Adolescent , Fractures, Open , Accidents, Traffic , Medical Records , Data Collection
2.
Rev. venez. cir. ortop. traumatol ; 54(2): 86-95, dic. 2022. ilus, tab
Article in Spanish | LILACS, LIVECS | ID: biblio-1516420

ABSTRACT

El objetivo de este trabajo es determinar las mediciones radiológicas del extremo proximal del fémur en pacientes adultos cuyos casos fueron presentados en las discusiones clínico-radiológicas del servicio de Traumatología y Ortopedia del Hospital Central de San Cristóbal entre 2015 y 2021. Se realizó un estudio prospectivo, descriptivo, transversal, que incluyó los estudios radiológicos de cadera sana en proyección anteroposterior de pelvis centrada en pubis con rotación interna de 15 %, de 126 pacientes entre 20 y 95 años. Se midieron: ángulo cervicodiafisario, lateralización femoral, longitud y ancho del cuello femoral y diámetro de la circunferencia cefálica, mediante el sotfware MicroDicom DICOM 4.0.0. La media de ángulo cervicodiafisario fue 130,8 ± 4,5 grados, en 57 individuos (45,2 %) estuvo entre 127,4 y 133,3 grados (p = 0,001); la circunferencia cefálica media fue 42,0 ± 2,4 mm, en 60 personas (47,6 %) estuvo entre 40,2 y 45,7 mm (p = 0,001); la longitud cervical media fue 78,6 ± 16,4 mm, en 54 individuos (42,9 %) estuvo entre 69,4 y 92 mm (p = 0,001); el ancho cervical medio fue 75,9 ± 12,1 mm, en 64 casos, (50,8 %) estuvo entre 62,9 y 78,7 mm (p = 0,001). En 60 individuos (47,6 %) la lateralización del fémur estuvo entre 92,6 - 117,7 mm. Las medidas son independientes del sexo; a medida que aumenta la edad, el ángulo cervicodiafisario es menor (p= 0,021). Se realizaron tablas percentiladas de las medidas radiológicas del extremo proximal del fémur, según edad y sexo, que pueden servir de referencia en pacientes futuros(AU)


The objective of this work is to determine the radiological measurements of the proximal end of the femur in adult patients whose cases were presented in the clinical-radiological discussions of the Traumatology and Orthopedics service of the Central Hospital of San Cristóbal between 2015 and 2021. A prospective study was carried out, descriptive, crosssectional, which included radiological studies of a healthy hip in anteroposterior projection of the pelvis centered on the pubis with internal rotation of 15%, of 126 patients between 20 and 95 years of age. The following were measured: cervicodiaphyseal angle, femoral lateralization, length and width of the femoral neck, and diameter of the head circumference, using the MicroDicom DICOM 4.0.0 software. The mean neck-diaphyseal angle was 130.8 ± 4.5 degrees, in 57 individuals (45.2%) it was between 127.4 and 133.3 degrees (p = 0.001); the mean head circumference was 42.0 ± 2.4 mm, in 60 people (47.6%) it was between 40.2 and 45.7 mm (p = 0.001); the mean cervical length was 78.6 ± 16.4 mm, in 54 individuals (42.9 %) it was between 69.4 and 92 mm (p = 0.001); the mean cervical width was 75.9 ± 12.1 mm, in 64 cases (50.8%) it was between 62.9 and 78.7 mm (p= 0.001). In 60 individuals (47.6%), the lateralization of the femur was between 92.6 - 117.7 mm. The measurements are independent of sex; as age increases, the cervical shaft angle is less (p= 0.021). Percentage tables of the radiological measurements of the proximal end of the femur were made, according to age and sex, which can serve as a reference in future patients(AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Femur/surgery , Hip , Radiology , Arthroplasty, Replacement , Proximal Femoral Fractures , Hip Fractures/surgery
3.
Cienc. Salud (St. Domingo) ; 3(2): 9-16, 20190726. ilus
Article in Spanish | LILACS | ID: biblio-1379138

ABSTRACT

Introducción: en el paisaje epidemiológico de la fascioliasis humana, dos aspectos son de fundamental importancia: a) presencia de hospederos definitivos (especialmente ganado bovino y humanos) parasitados con adultos del tremátodo y; b) presencia de hospederos intermediarios invertebrados, moluscos de la familia Lymnaeidae, en los que se desarrollan los estadios larvarios, además de plantas acuáticas de consumo humano. Material y métodos: con el objetivo de prevenir brotes de fascioliasis humana mediante la correcta identificación de aspectos de interés epidemiológico, un humedal fue seleccionado en el sector de Palo Blanco, municipio de Jarabacoa, provincia de La Vega, en el cual se realizó un estudio malacológico en octubre de 2016, en busca de especies de moluscos limneidos e hidrófitos asociados. En el laboratorio se obtuvieron los índices de infección natural y experimental a Fasciola hepatica. Resultados: se identificó el limneido Pseudosuccinea columella, en proporciones de 250 especímenes por persona/hora. El vegetal predominante fue el berro (Nasturtiun officinale), cultivado comercialmente en tres cuadrantes del humedal y en el otro cuadrante se observaron bovinos pastando. El índice de infección experimental de los moluscos fue de 94 % a la cepa simpátrica de F. hepatica de Dajabón; no se encontraron moluscos parasitados naturalmente. Conclusiones: Pseudosuccinea columella debe considerarse como un molusco de relevancia epidemiológica en la transmisión de la fascioliasis en República Dominicana, a tenor de su dispersión y elevado índice de infección experimental obtenido en el presente estudio


Introduction: in the epidemiological landscape of human fascioliasis, two aspects are of fundamental importance: a) presence of definite hosts (especially cattle and humans) parasitized with trematode adults and b) presence of invertebrate intermediate hosts, mollusks of the family Lymnaeidae, in which larval stages develop, in addition to aquatic plants for human consumption. Material and methods: in order to prevent outbreaks of human fascioliasis by correctly identifying aspects of epidemiological interest, a wetland was selected in the sector of Palo Blanco, municipality of Jarabacoa, province of La Vega, in which a malacological study was carried out in October 2016, in search of limneid mollusk species and associated hydrophytes. Natural and experimental infection rates to Fasciola hepaticawere obtained in the laboratory. Results: the lymnaeid Pseudosuccinea columella was identified, in proportions of 250 specimens collected per person/hour. The predominant vegetable was the watercress (Nasturtiun officinale), commercially cultivated in three quadrants of the wetland and in the other quadrant were observed cattle grazing. The rate of experimental infection of mollusks was 94 % to the sympatric strain of F. hepatica of Dajabón; no naturally parasitized mollusks were found. Conclusions: Pseudosuccinea columella should be considered as a mollusk of epidemiological relevance in the transmission of fascioliasis in the Dominican Republic, due to its dispersion and high rate of experimental infection obtained in the present study


Subject(s)
Fascioliasis , Intestinal Diseases, Parasitic , Dominican Republic