Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Cancer Research and Treatment ; : 258-269, 2023.
Article in English | WPRIM | ID: wpr-966471

ABSTRACT

Purpose@#This study aimed to compare treatment outcomes and toxicity profile between imaged-guided brachytherapy (IGBT) versus conventional brachytherapy (CBT) performed by the same practitioner during the same time period. @*Materials and Methods@#Medical records of 104 eligible patients who underwent brachytherapy for locally advanced cervical cancer were retrospectively reviewed. Fifty patients (48.1%) underwent IGBT, and 54 (51.9%) patients underwent CBT. All patients underwent concurrent chemoradiation with cisplatin. High-dose-rate intracavitary brachytherapy with dose prescription of 25-30 Gy in 4-6 fractions was performed for all patients. Late lower gastrointestinal (GI) and urinary toxicities occurred more than 3 months after the end of brachytherapy were included for comparative and dosimetric analyses. @*Results@#The median follow-up period was 18.33 months (range, 3.25 to 38.43 months). There were no differences in oncologic outcomes between the two groups. The IGBT group had lower rate of actuarial grade ≥ 3 toxicity than the CBT group (2-year, 4.5% vs. 25.7%; p=0.030). Cumulative equieffective D2cc of sigmoid colon was significantly correlated with grade ≥ 2 lower GI toxicity (p=0.033), while equieffective D2cc of rectum (p=0.055) and bladder (p=0.069) showed marginal significance with corresponding grade ≥ 2 toxicities in the IGBT group. Half of grade ≥ 3 lower GI toxicities impacted GI tract above the rectum. Optimal thresholds of cumulative D2cc of sigmoid colon and rectum were 69.7 Gy and 70.8 Gy, respectively, for grade ≥ 2 lower GI toxicity. @*Conclusion@#IGBT showed superior toxicity profile to CBT. Evaluating the dose to the GI tract above rectum by IGBT might prevent some toxicities.

2.
Radiation Oncology Journal ; : 260-269, 2022.
Article in English | WPRIM | ID: wpr-968571

ABSTRACT

Purpose@#Nasopharyngeal cancer (NPC) has a higher prevalence of regional nodal metastasis than other head and neck cancers; however, level IB lymph node involvement is rare. We evaluated the safety and feasibility of level IB-sparing radiotherapy (RT) for NPC patients. @*Materials and Methods@#We retrospectively reviewed 236 patients with NPC who underwent definitive intensity-modulated RT with or without chemotherapy between 2004 and 2018. Of them, 212 received IB-sparing RT, and 24 received non-IB-sparing RT. We conducted a propensity score matching analysis to compare treatment outcomes according to IB-sparing status. In addition, dosimetric analysis of the salivary glands was performed to identify the relationship between xerostomia and the IB-sparing RT. @*Results@#The median follow-up duration was 78 months (range, 7 to 194 months). Local, regional, and distant recurrences were observed in 11.9%, 6.8%, and 16.1% of patients, respectively. Of the 16 patients with regional recurrence, 14 underwent IB-sparing RT. The most common site categorization of regional recurrence was level II (75%), followed by retropharyngeal lymph nodes (43.8%); however, there was no recurrence at level IB. In the matched cohorts, IB-sparing RT was not significantly related to treatment outcomes. However, IB-sparing RT patients received a significantly lower mean ipsilateral and contralateral submandibular glands doses (all, p < 0.001) and had a lower incidence of chronic xerostomia compared with non-IB-sparing RT patients (p = 0.006). @*Conclusion@#Our results demonstrated that IB-sparing RT is sufficiently safe and feasible for treating NPC. To reduce the occurrence of xerostomia, IB-sparing RT should be considered without compromising target coverage.

3.
Radiation Oncology Journal ; : 27-35, 2012.
Article in English | WPRIM | ID: wpr-49997

ABSTRACT

PURPOSE: To evaluate the effect of common three photon energies (6-MV, 10-MV, and 15-MV) on intensity-modulated radiation therapy (IMRT) plans to treat prostate cancer patients. MATERIALS AND METHODS: Twenty patients with prostate cancer treated locally to 81.0 Gy were retrospectively studied. 6-MV, 10-MV, and 15-MV IMRT plans for each patient were generated using suitable planning objectives, dose constraints, and 8-field setting. The plans were analyzed in terms of dose-volume histogram for the target coverage, dose conformity, organs at risk (OAR) sparing, and normal tissue integral dose. RESULTS: Regardless of the energies chosen at the plans, the target coverage, conformity, and homogeneity of the plans were similar. However, there was a significant dose increase in rectal wall and femoral heads for 6-MV compared to those for 10-MV and 15-MV. The V20 Gy of rectal wall with 6-MV, 10-MV, and 15-MV were 95.6%, 88.4%, and 89.4% while the mean dose to femoral heads were 31.7, 25.9, and 26.3 Gy, respectively. Integral doses to the normal tissues in higher energy (10-MV and 15-MV) plans were reduced by about 7%. Overall, integral doses in mid and low dose regions in 6-MV plans were increased by up to 13%. CONCLUSION: In this study, 10-MV prostate IMRT plans showed better OAR sparing and less integral doses than the 6-MV. The biological and clinical significance of this finding remains to be determined afterward, considering neutron dose contribution.


Subject(s)
Humans , Head , Neutrons , Organs at Risk , Prostate , Prostatic Neoplasms , Retrospective Studies
4.
Radiation Oncology Journal ; : 96-96, 2012.
Article in English | WPRIM | ID: wpr-120927

ABSTRACT

The funding acknowledgment in this article was omitted as published.

5.
The Journal of the Korean Society for Therapeutic Radiology and Oncology ; : 50-56, 2010.
Article in English | WPRIM | ID: wpr-46387

ABSTRACT

PURPOSE: We report the results of an external audit on the absorbed dose of radiotherapy beams independently performed by third parties. For this effort, we developed a method to measure the absorbed dose to water in an easy and convenient setup of solid water phantom. MATERIALS AND METHODS: In 2008, 12 radiotherapy centers voluntarily participated in the external auditing program and 47 beams of X-ray and electron were independently calibrated by the third party's American Association of Physicists in Medicine (AAPM) task group (TG)-51 protocol. Even though the AAPM TG-51 protocol recommended the use of water, water as a phantom has a few disadvantages, especially in a busy clinic. Instead, we used solid water phantom due to its reproducibility and convenience in terms of setup and transport. Dose conversion factors between solid water and water were determined for photon and electron beams of various energies by using a scaling method and experimental measurements. RESULTS: Most of the beams (74%) were within +/-2% of the deviation from the third party's protocol. However, two of 20 X-ray beams and three of 27 electron beams were out of the tolerance (+/-3%), including two beams with a >10% deviation. X-ray beams of higher than 6 MV had no conversion factors, while a 6 MV absorbed dose to a solid water phantom was 0.4% less than the dose to water. The electron dose conversion factors between the solid water phantom and water were determined: The higher the electron energy, the less is the conversion factor. The total uncertainty of the TG-51 protocol measurement using a solid water phantom was determined to be +/-1.5%. CONCLUSION: The developed method was successfully applied for the external auditing program, which could be evolved into a credential program of multi-institutional clinical trials. This dosimetry saved time for measuring doses as well as decreased the uncertainty of measurement possibly resulting from the reference setup in water.


Subject(s)
Electrons , Phenylpropionates , Uncertainty , Water
6.
Korean Journal of Medical Physics ; : 231-240, 2008.
Article in Korean | WPRIM | ID: wpr-93136

ABSTRACT

We developed a user-friendly program to independently verify monitor units (MUs) calculated by radiation treatment planning systems (RTPS), as well as to manage beam database in clinic. The off-axis factor, beam hardening effect, inhomogeneity correction, and the different depth correction were incorporated into the program algorithm to improve the accuracy in calculated MUs. A beam database in the program was supposed to use measured data from routine quality assurance (QA) processes for timely update. To enhance user's convenience, a graphic user interface (GUI) was developed by using Visual Basic for Application. In order to evaluate the accuracy of the program for various treatment conditions, the MU comparisons were made for 213 cases of phantom and for 108 cases of 17 patients treated by 3D conformal radiation therapy. The MUs calculated by the program and calculated by the RTPS showed a fair agreement within +/-3% for the phantom and +/-5% for the patient, except for the cases of extreme inhomogeneity. By using Visual Basic for Application and Microsoft Excel worksheet interface, the program can automatically generate beam data book for clinical reference and the comparison template for the beam data management. The program developed in this study can be used to verify the accuracy of RTPS for various treatment conditions and thus can be used as a tool of routine RTPS QA, as well as independent MU checks. In addition, its beam database management interface can update beam data periodically and thus can be used to monitor multiple beam databases efficiently.


Subject(s)
Animals , Humans , Mice , Organothiophosphorus Compounds , Software
SELECTION OF CITATIONS
SEARCH DETAIL