Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Experimental Ophthalmology ; (12): 785-791, 2019.
Article in Chinese | WPRIM | ID: wpr-796587

ABSTRACT

Objective@#To compare the efficacy and visual quality of biocular cataract surgery combined with TECNIS Symfony intraocular lens(IOL) implantation in the correction of presbyopia with three different methods of reserved diopters.@*Methods@#A prospective cohort design was adopted.From October in 2016 to December in 2018, 120 patients 240 eyes with binocular cataract surgery implanted TECNIS Symfony IOL were divided into regular group, micro-near-vision group and micro-monovision group according to different reserved diopters, 40 patients 80 eyes in each group.The binocular IOL reserved diopter is + 0.10--0.20 D in regular group.The binocular IOL reserved diopter is -0.20--0.50 D in micro-near-vision group, meanwhile, the dominant eye reserved diopter is + 0.10--0.20 D, and the non-dominant eye reserved the myopia of -0.50--0.75 D in micro-monovision group.Defocus curves of single eye and binocular were measured and full distance visual acuity were analyzed 3 months after surgery.MTF values were detected by iTrace and compared between different groups.Visual function questionnaire of multifocal intraocular lenes (MIOLs)were analyzed and spectacle independence rate of presbyopia correction and disturbing photic phenomena were compared 3 months after surgery.This study protocol was approved by the ethics committee of Chongqing Aier Mega Eye Hospital, and this study followed the Declaration of Helsinki.@*Results@#Compared with regular group, the whole defocus curve of micro-near-vision group actually shifted to the right by 0.35 D, with almost no change in shape.The shape of the binocular defocus curve of micro-monovision group changed significantly compared with that of regular group, that is the wave peak became significantly wider, and the downward trend was more gentle.Spectacle independence rate of the three groups were all 100.00%, spectacle independence rate of intermediate distance in Micro-monovision group was 100.00%, which was higher than that of regular group(80.00%) and micro-near-vision group(90.00%), and the differences were statistically significant (χ2=37.04; P<0.01). The MTF value of the dominant eye was higher than that of the non-dominant eye in the Micro-monovision group, and the difference was statistically significant(t=3.74, P=0.001). There was no statistically significant difference in the occurrence rate of disturbing photic phenomena among the three groups(P>0.05).@*Conclusions@#Different reserved diopter design during cataract extraction combined with TECNIS Symfony IOL implantation suits different patients.Among the three different reserved diopters methods, the effect of micro-monovision method can obtain the highest spectacle independence rate, and provide satisfactory binocular far to near full-distance visual acuity.

2.
Chinese Journal of Experimental Ophthalmology ; (12): 785-791, 2019.
Article in Chinese | WPRIM | ID: wpr-790162

ABSTRACT

Objective To compare the efficacy and visual quality of biocular cataract surgery combined with TECNIS Symfony intraocular lens( IOL) implantation in the correction of presbyopia with three different methods of reserved diopters. Methods A prospective cohort design was adopted. From October in 2016 to December in 2018,120 patients 240 eyes with binocular cataract surgery implanted TECNIS Symfony IOL were divided into regular group,micro-near-vision group and micro-monovision group according to different reserved diopters,40 patients 80 eyes in each group. The binocular IOL reserved diopter is +0. 10--0. 20 D in regular group. The binocular IOL reserved diopter is -0. 20--0. 50 D in micro-near-vision group, meanwhile, the dominant eye reserved diopter is +0. 10--0. 20 D, and the non-dominant eye reserved the myopia of -0. 50--0. 75 D in micro-monovision group. Defocus curves of single eye and binocular were measured and full distance visual acuity were analyzed 3 months after surgery. MTF values were detected by iTrace and compared between different groups. Visual function questionnaire of multifocal intraocular lenes ( MIOLs ) were analyzed and spectacle independence rate of presbyopia correction and disturbing photic phenomena were compared 3 months after surgery. This study protocol was approved by the ethics committee of Chongqing Aier Mega Eye Hospital, and this study followed the Declaration of Helsinki. Results Compared with regular group, the whole defocus curve of micro-near-vision group actually shifted to the right by 0. 35 D,with almost no change in shape. The shape of the binocular defocus curve of micro-monovision group changed significantly compared with that of regular group,that is the wave peak became significantly wider,and the downward trend was more gentle. Spectacle independence rate of the three groups were all 100. 00%, spectacle independence rate of intermediate distance in Micro-monovision group was 100. 00%, which was higher than that of regular group (80. 00%) and micro-near-vision group(90. 00%),and the differences were statistically significant (χ2=37. 04;P<0. 01). The MTF value of the dominant eye was higher than that of the non-dominant eye in the Micro-monovision group,and the difference was statistically significant(t=3. 74,P=0. 001). There was no statistically significant difference in the occurrence rate of disturbing photic phenomena among the three groups(P>0. 05). Conclusions Different reserved diopter design during cataract extraction combined with TECNIS Symfony IOL implantation suits different patients. Among the three different reserved diopters methods, the effect of micro-monovision method can obtain the highest spectacle independence rate, and provide satisfactory binocular far to near full-distance visual acuity.

SELECTION OF CITATIONS
SEARCH DETAIL