Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
1.
Chinese Journal of Cardiology ; (12): 742-749, 2023.
Article in Chinese | WPRIM | ID: wpr-984712

ABSTRACT

Objective: To explore the long-term clinical efficacy of transcatheter repair of mitral paravalvular leak (PVL) post surgical mitral valve replacement. Methods: This study is a retrospective study. Patients who completed transcatheter repair of paravalvular leak after surgical mitral valve replacement at Shanghai Chest Hospital, Shanghai Jiaotong University School of Medicine from March 2010 to December 2018 were included. Technical success was defined as the occluder being stably implanted in the paravalvular leak site without affecting the function of the mitral valve and surrounding tissues; and there were no intervention-related complications, such as new hemolysis or aggravated hemolysis, and echocardiography confirmed mitral paravalvular regurgitation reduced by more than 1 grade. Patients were followed up at 30 days, 1, and 3 years after the intervention. The main endpoints were all-cause death and re-surgery due to interventional failure or serious complications. The occurrence of occluder-mediated hemolysis and chronic renal insufficiency was recorded, and patients were monitored with echocardiography during follow up. Results: A total of 75 patients were included, aged (54.3±22.9) years old, and 38 patients were males. All patients had decreased cardiac function and/or hemolysis before intervention. Procedural success was achieved in 54 patients (72.0%). Incidence of device-mediated hemolysis was 18.7% (14/75). During the follow-up period, all-cause death occurred in 7 patients (9.3%), and 3 were cardiac deaths.The 3-year event-free survival rate was 81.3% (61/75). The need for cardiac surgery was 9.3% (7/75): 3 cases due to severe device-mediated hemolysis, 2 cases due to prosthetic valve failure and 2 cases due to moderate to severe residual regurgitation. The echocardiography follow-up results showed that the position of the occluder was stable, there was no impact on the artificial valve function and surrounding structures, and the residual regurgitation was stable without progressive increase in event-free patients. Compared with pre-intervention, the left ventricular end systolic diameter ((33.9±7.4)mm vs. (38.3±8.9) mm, P=0.036), end diastolic diameter ((53.7±8.3) mm vs. (58.4±9.1) mm, P=0.045) and left atrial diameter (59.3 (44.5, 90.7) mm vs. 64.3 (44.8, 96.6) mm, P=0.049) were significantly reduced, pulmonary artery systolic pressure was also significantly decreased ((36.5±15.8) mmHg vs. (46.3±14.9) mmHg, P=0.022, 1 mmHg=0.133 kPa). There was no significant difference between 3 years and 1 year after transcatheter repair of mitral paravalvular leak post surgical mitral valve replacement (all P>0.05). Conclusion: Transcatheter repair of mitral paravalvular leak post surgical mitral valve replacement is an effective treatment option in selective patients.


Subject(s)
Male , Humans , Adult , Middle Aged , Aged , Female , Mitral Valve/surgery , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Retrospective Studies , Hemolysis , China , Mitral Valve Insufficiency/surgery , Treatment Outcome , Cardiac Catheterization , Prosthesis Failure
SELECTION OF CITATIONS
SEARCH DETAIL