Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Malaysian Orthopaedic Journal ; : 29-33, 2010.
Article in English | WPRIM | ID: wpr-628124

ABSTRACT

In total knee arthroplasty, mechanical alignment guides have improved the accuracy of implant alignment, but errors are not uncommon. In the present study, an image free computer assisted navigation system was used to analyse the accuracy of an extramedullary (tibial) alignment system, which is based on predetermined, fixed anatomical landmarks. Comparisons were made between two surgeons, with different levels of competency in order to determine if experience affected the accuracy of extramedullary tibial

2.
Malaysian Orthopaedic Journal ; : 8-11, 2010.
Article in English | WPRIM | ID: wpr-628059

ABSTRACT

This retrospective radiographic analysis of 57 patients (62 knees) examined two possible factors involved in pin tract fractures of the femur due to navigated total knee arthroplasty (TKA): the angle of the tracker pin with respect to the lateral femoral cortex, and the distance between the tracker pin and the lateral joint line. Our findings demonstrate a relationship between postoperative pin tract induced stress fractures (3 patients), with pin tract angles exceeding 15. Pin placement at a site more th

3.
Malaysian Orthopaedic Journal ; : 24-28, 2009.
Article in English | WPRIM | ID: wpr-628753

ABSTRACT

Current available implants for total knee replacement are based on the mormphometry of the Caucasian knee. We believe there are significant morphometric differences in the Asian knee that will be relevant in future implant designs. Sixty nine consecutive patients (80 knees) underwent computer navigated primary total knee arthroplasty. The anterior posterior (AP) length, and the medial lateral (ML) width of the distal femur, were analyzed, with respect to the final sizing details of four implants (femoral component) commonly used locally. The mean AP length was 59.9 (SD 4.8) mm, and the mean ML width was 65.0 (SD 5.0) mm. The overall mean aspect ratio (ML/AP) was 1.09 (SD 0.07). The mean aspect ratio for females was 1.08 (SD 0.07). Both were smaller than the aspect ratio of the implants which ranged from 1.11 to 1.13. All four implants tend to overhang at the medial lateral width of the distal femur. This is more obvious in females. Future implant designs should provide more ML wdth sizes for a given AP length, in addition to gender differences, for ths population.

4.
Malaysian Orthopaedic Journal ; : 32-35, 2009.
Article in English | WPRIM | ID: wpr-628337

ABSTRACT

Necrotizing fasciitis is a life and limb threatening soft tissue infection with a high mortality rate. This study tries to identify the possible risk factors that contribute to mortality in patients with necrotizing fasciitis involving a lower limb. We prospectively reviewed 41 patients that presented with necrotizing fasciitis of the lower limb over a period of one year. Results show that the mortality rate for necrotizing fasciitis of the lower limb is quite high at 19.5%. Comparison among necrotizing fasciitis patients reveals that higher mortality rate is seen among those patients with advanced age and those presented with initial high pre operative creatinine levels. Sex, pre morbid diabetes mellitus, duration from initial symptoms to presentation for treatment and presence of streptococcus group A were not associated with an increased mortality rate. Neither were admission vital signs, subcutaneous gas on radiograph, prior antibiotic treatment on admission or clinical note of bullae formation.

5.
Malaysian Orthopaedic Journal ; : 39-41, 2007.
Article in English | WPRIM | ID: wpr-627373

ABSTRACT

A 27 year old patient with ameloblastoma of the mandible underwent anterior mandibulectomy and reconstruction with left fibula osteocutaneous flap. The bone was shaped at the lower limb before cutting the pedicle. Vascularised free fibula flap provides a good alternative to other bone grafts in mandible reconstruction as it is relatively easy to perform, carries a low complication rate, and mandibular shaping with intact pedicle cuts down on ischaemic as well as total operative time.

SELECTION OF CITATIONS
SEARCH DETAIL