1.
Rev. bras. oftalmol ; 68(5): 291-295, set.-out. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-536431

ABSTRACT

A ecografia se constitui em método importante na avaliação de anormalidades do segmento posterior do globo ocular. OBJETIVO: Comparar as vantagens e desvantagens da sonda de 10 e 20 MHz da ultra-sonografia B-scan, na avaliação de imagens do segmento posterior do globo ocular. MÉTODOS: Pacientes acompanhados no ambulatório do Hospital das Clínicas da USP (HCFMUSP) entre fevereiro de 2006 e abril de 2007 foram submetidos a exame ultra-sonográfico usando o aparelho CINE-Scan® (Quantel Medical Inc.) com sondas de 10 e 20 MHz. Os pacientes foram examinados por três oftalmologistas experientes, em decúbito dorsal, após instilação de colírio de tetracaína a 1 por cento, inicialmente com a sonda sobre as pálpebras e em seguida diretamente em contato com a esclera ou córnea. As imagens obtidas com sondas de 10 e 20 MHz foram comparadas entre si, durante e após a realização do exame. RESULTADOS: A sonda de 20 MHz mostrou-se superior na avaliação da detecção, forma e limites de estruturas do pólo posterior e a de 10 MHz avaliou com mais detalhes o humor vítreo. Não foram encontradas diferenças nas imagens obtidas com exame transpalpebral ou transescleral com a sonda de 10 MHz. Com a sonda de 20 MHz, as imagens obtidas em contato direto com o globo ocular apresentaram melhor qualidade. CONCLUSÕES: As sondas de 10 e 20 MHz têm diferentes intervalo de alcance ideal, assim como diferentes meios específicos de aquisição de melhores imagens.


The ultrasound is an important method in the evaluation of abnormalities of the posterior segment of the eye. PURPOSE: To compare the advantages and disadvantages of 10 and 20 MHz probe on B- scanning ultra-sonography in evaluation of vitreous and posterior pole diseases, providing recommendations for their use. METHODS: Patients from Hospital das Clinicas of the University of São Paulo (HC-FMUSP), attended between February 2006 and April 2007, were submitted to ultrasound exams using CINE-Scan® (Quantel Medical Inc) B-scan with 10 and 20MHz probe. The patients were examined by three experienced ophthalmologists, in horizontal dorsal position, after instillation of tetracaine 1 percent drops, first with the probe in direct contact with eyelids, and then with the probe placed directly in contact with the sclera or cornea. Theimages obtained were compared immediately during and after the examination. RESULTS: The 20 MHz probe reveled a superior resolution to study details, like shape and limits, on the posterior pole, and the 10 MHz probe provided better evaluation on vitreous humor. There were no differences if the exam was performed on eyelids or directly on sclera with the 10 MHz probe, but with the 20 MHz probe, the images had better resolution when the probe was used in direct contact with the eye. CONCLUSIONS: The 10 and 20 probes have different ideal range of reach, as different better specific means of image achieving.


Subject(s)
Vitreous Body/abnormalities , Diagnostic Techniques, Ophthalmological , Eye Abnormalities , Orbital Diseases , Eye Diseases/diagnosis , Eye Diseases , Retina
2.
Clinics ; 64(7): 637-640, 2009. tab
Article in English | LILACS | ID: lil-520794

ABSTRACT

INTRODUCTION: A cataract is defined as an opacity of any portion of the lens, regardless of visual acuity. In some advanced cases of cataracts, in which good fundus visualization is not possible, an ultrasound examination provides better assessment of the posterior segment of the globe. OBJECTIVES: This study aims to evaluate the ultrasonographic records of patients with advanced cataracts who were examined during cataract campaigns.METHODS: The ultrasonographic findings obtained from 215 patients examined in cataract campaigns conducted by the Hospital das Clínicas Department of Ophthalmology of the Faculdade de Medicina da Universidade de São Paulo between the years of 2005 and 2007 were evaluated, and the utility of this exam in changing the treatment procedures was studied. RESULTS: A total of 289 eyes from 215 patients were examined. Of the eyes examined, 77.5% presented with findings in the vitreous cavity and the posterior pole. A posterior vitreous detachment with no other complications was observed in 47.4% of the eyes. The remaining 30.1% presented with eye diseases that could result in a reduced visual function after surgery. The most frequent eye diseases observed were diffuse vitreous opacity (12.1% of the eyes) and detachment of the retina (9.3% of the eyes). DISCUSSION: In many cases, the ultrasonographic evaluation of the posterior segment revealed significant anomalies that changed the original treatment plan or contra-indicated surgery. At the very least, the evaluation was useful for patient counseling. CONCLUSION: The ultrasonographic examination revealed and differentiated between eyes with cataracts and eyes with ocular abnormalities other than cataracts as the cause of poor vision, thereby indicating the importance of its use during ocular evaluation.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Cataract , Eye Abnormalities , Health Promotion , Brazil , Cataract/therapy , Eye , Retrospective Studies , Retinal Detachment , Vitreous Body , Visual Acuity/physiology , Vitreous Detachment , Young Adult