Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Cardiology ; (12): 536-539, 2007.
Article in Chinese | WPRIM | ID: wpr-307253

ABSTRACT

<p><b>OBJECTIVE</b>To investigate the association of MspI polymorphism of Cytochrome P4501A1 (CYP1A1) gene and smoking to the susceptibility to coronary artery disease (CAD).</p><p><b>METHODS</b>The genotypes of CYP1A1 MspI site were detected using the methods of polymerase chain reaction restriction fragment length polymorphism (PCR-RFLP) in 349 cases with CAD and 404 non-CAD as controls. CAD diagnosis was confirmed by coronary angiograms. Genetic risk of CYP1A1 genotypes was analyzed by smoking index (SI).</p><p><b>RESULTS</b>The frequency of the predominant homozygotes TT, heterozygotes TC and the rare homozygotes CC in CAD group were not different with that of the controls (chi(2) = 3.224, P = 0.200). But in the smokers, the frequency of CC in CAD group was higher than that of non-CAD group (P = 0.002), while its odds ratio was 3.142 [95% confidence interval (CI) 1.481 - 6.668]. The odds ratio of genotype CC and heterozygote TC was 2.215 (95% CI 1.087 - 4.510) in the low dose cigarette smoking group, and was 1.407 (95% CI 0.709 - 2.791) in the high dose cigarette smoking group.</p><p><b>CONCLUSION</b>Both MspI polymorphism of CYP1A1 gene and smoking exposure promote the development of CAD.</p>


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Coronary Artery Disease , Genetics , Cytochrome P-450 CYP1A1 , Genetics , Gene Frequency , Genetic Predisposition to Disease , Genotype , Polymorphism, Genetic , Smoking , Genetics
2.
Chinese Journal of Emergency Medicine ; (12)2006.
Article in Chinese | WPRIM | ID: wpr-682908

ABSTRACT

Objective To observe the rate-adaptive response of dual sensor pacemakers integrated with activity sensor and minute ventilation sensor.Methods Fifty patients with chronotrepic incompetence were implanted with pacemakers of integrated sensor.The patients with pacemakers implanted were arranged to take upstairs test,downstairs test and tapping test under the monitor of integrated sensor,minute ventilation sensor and activity sensor respectirely.The rate-adaptive responses were tracked down every 15 seconds with remote heart rate monitor.The results were compared with the control group patients with normal sinal chronotropic function(n=15).Results In activity sensor group,pacing rates were significantly higher than the normal control group in downstairs test and tapping test.In minute ventilation sensor group,pacing rates increasement was significantly slower in the beginning of upstairs test.Pacing rates of integrated group were similar to the normal control group in upstairs and downstairs tests.Conclusion The rate-adaptive pacing response of dual sensor integrated with activity sensor and minute ventilation sensor,which is mostly close to the normal chronotropic response,better than that of single sensor.

SELECTION OF CITATIONS
SEARCH DETAIL