This paper presented a design of broadly all solid-state tunable pulsed Ti:sapphire laser with high power and stable performance. The laser was pumped by custom-made Nd:YAG laser which had water cooling system and amplified by two stage amplifier. The method accomplished tunable output of all solid-state tunable pulsed Ti:sapphire laser by modifying the reflection angle of the back mirror. We investigated the relationship between the power of the pumping laser and the all solid-state tunable pulsed Ti: sapphire laser by changing the power of the pumping source.


Subject(s)
Aluminum Oxide , Equipment Design , Laser Therapy , Lasers, Solid-State , Titanium
2.
Chinese Journal of Medical Instrumentation ; (6): 326-328, 2012.
Article in Chinese | WPRIM | ID: wpr-342937

ABSTRACT

Solid-state multi-wavelength laser equipment is the treatment device with selected wavelength Nd: YAG laser frequency technology, integrated red (659 nm), yellow (589 nm) and green (532 nm) of three solid-state lasers. The device is designed by the accurate controlled laser output system, precision optical and electronic control through the optical coupler into the optical fiber transmission system. It's combined with an eye slit lamp integration of high precision, good stability stability for all solid-state multi-wavelength lasers equipment.


Subject(s)
Equipment Design , Fundus Oculi , Laser Therapy , Lasers, Solid-State , Therapeutic Uses , Retinal Diseases , General Surgery
3.
Chinese Journal of Medical Instrumentation ; (6): 161-163, 2011.
Article in Chinese | WPRIM | ID: wpr-330491

ABSTRACT

The proposed hybrid image segmentation method, based on MRI renal images, aims at extracting the cortical and medullary regions of the kidney. It incorporates the thresholding segmentation and the active contour model. To begin with, the binary mask was obtained by preprocessing and thresholding. Then, the manually set starting contour deformed like a balloon under the framework of a simplified active contour model, thus getting the initial contour of the medulla or the cortex. Finally, the initial contour deformed according to the traditional active contour model and was attracted by the actual boundary of the tissues, defined by the gradient image.


Subject(s)
Humans , Algorithms , Image Interpretation, Computer-Assisted , Methods , Image Processing, Computer-Assisted , Methods , Kidney , Magnetic Resonance Imaging , Methods
4.
Chinese Journal of Medical Instrumentation ; (6): 339-342, 2010.
Article in Chinese | WPRIM | ID: wpr-281088

ABSTRACT

According to the mechanism of spectral domain optical coherence tomography, this paper gives a design and development of a practical OCT imaging device based on slit-lamp microscopic widely-used in ophthalmology. The paper details the device's architecture and three key points in design: communication between PC and MCU, how to design modules of fixation lamp and reference arm and anti-interference measures.


Subject(s)
Diagnostic Techniques, Ophthalmological , Equipment Design , Tomography, Optical Coherence , Methods