Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Type of study
Year range
1.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 366-371, 2023.
Article in Chinese | WPRIM | ID: wpr-986015

ABSTRACT

Objective: To establish ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the determination of 22 phospholipids in serum. Methods: In September 2022, Using synthetic non endogenous phospholipids as internal standard, phospholipids in serum were extracted by methanol-dichloromethane (2∶1, V/V) protein precipitation method. Chromatographic separation was achieved on an ACQUITY UPLC BEH shield RP18 column, and the mobile phase was methanol/water (5∶95, V/V) containing 10 mM ammonium formate and methanol. Detection was performed in multiple reaction monitoring mode with ion mode switching. And the method was applied by analyzing phospholipids in the serum of coal workers' pneumoconiosis patients. Results: The 22 phospholipids showed good linear relationships in their respective concentration ranges and the correlation coefficients were higher than 0.990. The spiked recoveries of the 22 phospholipids were 81.03%-121.63% at the three spiked levels. The intra-assay were less than 14.52%, and the inter-assay were less than 15.00%. Conclusion: The method with the advantages of simplicity, stability and high sensitivity, and it can be used for the analysis of phospholipids in serum.


Subject(s)
Humans , Chromatography, Liquid , Chromatography, High Pressure Liquid/methods , Tandem Mass Spectrometry/methods , Phospholipids , Methanol
2.
Biomedical and Environmental Sciences ; (12): 379-384, 2016.
Article in English | WPRIM | ID: wpr-258809

ABSTRACT

Case reports of indium-related lung disease in workers have raised public concern to the human toxicity of indium (In) and its compounds. However, studies evaluating the exposure or health of workers in In smelting plants are rare. Therefore, in this study, we focused on four In smelting plants, with the main objective of characterizing In in smelter plants in China and discussing the potential exposure biomarkers of In exposure. We recruited 494 subjectsat four In smelting plants in China. Personal air samples, first morning urine and spot blood samples were collected. In concentrations in samples were analyzed using inductively coupled plasma mass spectrometry. In concentrations in air samples did not exceed the permissible concentration-time weighed average, but the smelter workers had a higher internal exposure to In. Positive correlations were observed between the air In and urine In concentrations, and between the air In and blood In concentrations. This study provides basic data for the following In exposure and health risk assessment.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Air Pollutants, Occupational , Blood , Urine , Biomarkers , Blood , Urine , China , Environmental Monitoring , Indium , Blood , Urine , Mass Spectrometry , Metallurgy , Occupational Exposure
3.
Chinese Journal of Preventive Medicine ; (12): 679-682, 2012.
Article in Chinese | WPRIM | ID: wpr-326249

ABSTRACT

<p><b>OBJECTIVE</b>To evaluate the chromium (Cr) levels in blood and urine among general population in China between 2009 and 2010, and thereby to analyze its prevalent features.</p><p><b>METHODS</b>From year 2009 to 2010, a total of 11 983 subjects of general population aged between 6 and 60 year-old were recruited from 24 districts in 8 provinces in eastern, central and western China mainland, by cluster random sampling method. The information about their living environment and health status were collected by questionnaire, and 11 983 blood samples and 11 853 urine samples were also collected. Inductively coupled plasma mass spectrometry (ICP-MS) was applied to test the Cr level both in blood and urine; and the Cr distribution in blood and urine among groups of population in different ages, genders and districts, were then analyzed.</p><p><b>RESULTS</b>Among general population in China, the geometric mean (GM) of Cr concentration in blood was 1.19 µg/L, with median at 1.74 µg /L and 95% percentile at 5.59 µg/L. The Cr concentration in blood among males and females were separately 1.18 µg/L and 1.20 µg/L(P > 0.05); while its GM in the groups of population aged 6 - 12, 12 - 16, 16 - 20, 20 - 30, 30 - 45 and 45 - 60 years old were 1.00, 1.22, 1.01, 1.40, 1.27 and 1.30 µg/L (P < 0.01), respectively; and the figures in populations from eastern, central and western China were 1.00, 1.70 and 1.98 µg/L (P < 0.01), respectively. Among general population, the GM of Cr concentration in urine was 0.53 µg/L, with median was lower than 0.42 µg/L and 95% percentile at 3.53 µg/L. The Cr concentration in urine among males and females were separately 0.52 µg/L and 0.53 µg/L (P > 0.05);while its GM in the groups of population aged 6 - 12, 12 - 16, 16 - 20, 20 - 30, 30 - 45 and 45 - 60 years old were 0.56, 0.60, 0.52, 0.50, 0.52 and 0.46 µg/L (P < 0.01), respectively;and the figures in populations from eastern, central and western China were 0.58, < 0.42 and 0.60 µg/L (P < 0.01), respectively.</p><p><b>CONCLUSION</b>The study reported the Cr levels in blood and urine among general population in China, and thereby provided basic data evidence for the following Cr biological monitoring studies in near future.</p>


Subject(s)
Adolescent , Adult , Child , Female , Humans , Male , Middle Aged , Young Adult , China , Chromium , Blood , Urine , Population Surveillance
4.
Chinese Journal of Preventive Medicine ; (12): 745-749, 2012.
Article in Chinese | WPRIM | ID: wpr-326235

ABSTRACT

<p><b>OBJECTIVE</b>To establish an inductively coupled plasma mass spectrometry(ICP-MS) method for determination of 30 trace elements including As, Ba, Be, Bi, Ni, Cd, Co, Cr, Cs, Cu, Ga, Mn, Pb, Sr, Tl, V, Ge, Mo, Nb, Ti, W, Te, Se, Zr, In, Sb, Hg, Ce, La, and Sm in human blood.</p><p><b>METHOD</b>The blood samples were analyzed by ICP-MS after diluted 1/10 with 0.01% Triton-X-100 and 0.5% nitric acid solution. Y, Rh and Lu were selected as internal standard in order to correct the matrix interference of Cr, As, Se, and Hg by a hex pole-based collision-reaction cell. Other elements were determined with standard method. The limits of detection, precision and accuracy of the method were evaluated. The accuracy was validated by the determination of the whole blood reference material.</p><p><b>RESULTS</b>All the 30 trace elements have good linearity in their determination range, with the correlation coefficient > 0.9999. The limits of detection of the 30 trace elements were in the range of 1.19 - 2.15 µg/L and the intra-precision and inter-precision (relative standard deviation, RSD) were less than 14.3% (except Hg RSD < 21.2%, and Ni RSD < 15.4%). The spiked recovery for all elements fell within 59.3% - 119.2%. Among the 13 whole blood reference materials, V, Cr, Mn, Co, Ni, Cu, As, Se, Cd, Te, and Pb (1.45, 1.19, 18.40, 0.18, 1.57, 591.00, 2.97, 61.00, 0.35, 1.86, and 9.70 µg/L respectively) fell within the acceptable range and the detection results of Hg (0.59 µg/L) and Mo (1.59 µg/L) were slightly beyond the range.</p><p><b>CONCLUSION</b>This method was simple, fast and effective. It can be used to monitor the multi-elementary concentration in human blood.</p>


Subject(s)
Humans , Limit of Detection , Mass Spectrometry , Methods , Metalloids , Blood , Metals , Blood , Trace Elements , Blood
5.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 452-454, 2011.
Article in Chinese | WPRIM | ID: wpr-282573

ABSTRACT

<p><b>OBJECTIVE</b>A sampling method was established to collect diborane in the air of workplace and an ICP-AES method was developed to determine the Boron in desorbed solution.</p><p><b>METHOD</b>Diborane in the air of workplace was collected by solid sorbent tube filled with oxidant impregnated activated carbon. The adsorbed diborane was desorbed into 3% H2O2 aqueous, and then the desorbed Boron was determined by ICP-AES.</p><p><b>RESULTS</b>The sampling efficiency of this method was 99.6% with the desorption efficiency of diborane with 5.660 microg and 56.6 microg spiked were 90.9% and 99.5%, respectively. Both the intra-and inter-precision RSD were less than 8%. The standard curve of this method ranged from 0.1 to 10.0 microg/ml (Boron), and the LOD and LOQ were 0.011 mg/m3 and 0.035 mg/m3 (15L samples) respectively.</p><p><b>CONCLUSION</b>The method established was suitable for diborane sampling and determination in the air of workplace.</p>


Subject(s)
Air Pollutants, Occupational , Borohydrides , Environmental Monitoring , Methods , Spectrophotometry, Atomic , Methods , Workplace
SELECTION OF CITATIONS
SEARCH DETAIL