Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of General Practitioners ; (6): 59-62, 2018.
Article in Chinese | WPRIM | ID: wpr-666118

ABSTRACT

Total 3 483 students in 4 to 9 grade from primary and middle school in Xiling District of Yichang city were selected by stratified cluster random sampling method between September and October 2016 to participate in screening for abnormal angle of trunk rotation(ATR),including 1 797 boys and 1 686 girls aged 9-15 years.The ATR was measured with Scoliometer and the ATR >5°was defined as abnormal.The overall abnormal ATR rate was 7.60%(265/3 483), that in boys was 4.73%(85/1797)and in girls was 10.68%(180/1 686)(χ2=43.75,P<0.05).The abnormal ATR rate in age group 13-15 was higher than that in age group 9-12[10.62%(159/1 496)vs.5.33%(106/1 987),χ2=36.92,P<0.01].Students with low BMI had higher abnormal ATR rate than that with normal or higher BMI(χ2=30.00,P<0.01);and students with left handedness had lower abnormal ATR rate than that with right handedness or double handedness(χ2=6.59,P=0.04).The abnormal ATR rate was not associated with dietary habits or sports in the daily life of students.The results show that gender,age,BMI and handedness affect abnormal rate of ATR.

2.
Chinese Journal of Physical Medicine and Rehabilitation ; (12): 690-693, 2009.
Article in Chinese | WPRIM | ID: wpr-380318

ABSTRACT

Objective To evaluate the test-retest and inter-rater reliability of the hand-held pressure algometer as a measuring instrument of pressure pain threshold(PPT).Method A total of 37 healthy subjects were recruited for reliability test.Three raters measured the PPT at 12 body sites of the subjects.Each rater conducted three trials on each site.In the validity test,10 patients with active trigger points in the upper trapezius were recruited and measured by one rater using the pressure algometer for PPT,the visual analogue scale(VAS)was also used to evaluate the pain intensity induced by the trigger point.The intraclass correlation coefficient and Spearman correlation coefficient were calculated to reflect the reliability and validity.Results The test-retest and inter-rater reliabilities were both high(ICC>0.95),with the measurements by one rater were more reliable than measurements by multiple raters.The inter-rater reliability of PPT measurement obtained by using the mean value of 3 trials was higher than any of the 3 trials alone.The PPT values of the trigger points were higher than those of the normal points,and there was a significantly negative correlation between the PPT values of the trigger points and the VAS scores.Conclusion The intra-and inter-rater PPT measurements in healthy subjects obtained with the hand-held pressure algometer were highly reliable.The algometer was valid for quantifying myofascial trigger point sensitivity.

SELECTION OF CITATIONS
SEARCH DETAIL