Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Medical Science Research Management ; (4): 478-481,485, 2015.
Article in Chinese | WPRIM | ID: wpr-603722

ABSTRACT

Objective To test and validate the comprehensiveness,usability and reliability of the questionnaire we made for publicity efforts of biobanking activities in China.We aim to learn public attitudes toward biobanking donation of biological materials,collection and long-term storage for biomedical research.Methods In the cross-sectional study,292 participants were interviewed with the self-administered questionnaire.The survey questionnaire presents an extensive battery of questions on demographic information,participation of previous studies,cognition of biobank and related concepts,opinions on biobank-related issues and trust on healthcare system.Different statistic methods were taken to do item analysis,reliability and validity evaluation.Results The Cronbach's α coefficient of the whole questionnaire was 0.850 and the cognition and attitude were the two factors with the highest internal reliability.All the Spearman correlation coefficients were large than 0.5 (p<0.01) . Three factors explained 59.2% of the questionnaire structure found by factor analysis,and all factors could be regarded as cognition factors,attitude factors and behaviors factors.Conclusions The survey questionnaire is evaluated to be reliable and applicable to gathering data on publicity efforts to assess the public attitude towards biobanking activities in China.

2.
Chinese Journal of Radiation Oncology ; (6): 560-563, 2015.
Article in Chinese | WPRIM | ID: wpr-476432

ABSTRACT

Objective To compare set?up error and the positioning and error correction time between the infrared markers automatic positioning+ ExacTrac ( A) and the manual positioning+ cone?beam computed tomography ( CBCT) image?guided radiotherapy ( IGRT) ( B) in intensity?modulated radiotherapy ( IMRT) for lung cancer. Methods A total of 20 patients with lung cancer were randomly divided into Group A and Group B. In Group A, after automatic positioning, a group of orthogonal X?rays images were taken using kV X?rays, which matched digitally reconstructed radiographs to obtain errors before correction. In group B, after manual positioning, images were taken using CBCT, which matched reference computed tomography images to obtain errors before correction. The positioning and error correction time was recorded in both groups. After error correction, errors after correction were obtained in each group using IGRT. Between?group comparison was made using the paired t test. Results The errors in lateral, longitudinal, vertical, and spinning vertical directions were significantly reduced after correction in both Group A and B (A:1.8±1?3 vs. 0.4±0?1, P=0?000;2.7±1?9 vs. 0.5±0?1, P=0?000;2.8±1?7 vs. 0.4±0?1, P=0?000;1.6±1?0 vs. 0.3±0?9, P=0?000;B:2.6±1?9 vs. 0.5±0?5, P=0?000;3.1±2?5 vs. 0.6±0?6, P=0?000;2.1±1?8 vs. 0.5±0?5, P=0?000;0.9±0?7 vs. 0.3±0?1, P=0?000). There were no significant differences in errors after correction between Group A and Group B (0.4±0?1 vs. 0.5±0?5, P=0?204;0.5±0?1 vs. 0.6± 0?6, P=0?257;0.4± 0?1 vs. 0.5± 0?5, P=0?518;0.3± 0?9 vs. 0.3± 0?1, P=0?755 ) . However, the positioning and error correction time in Group A was significantly shorter than that in Group B (199.1±16?2 vs. 315.2±13?7, P=0?000). Conclusions The application of ExacTrac or CBCT IGRT can substantially reduce set?up errors and improve set?up accuracy in IMRT. In addition, the application of the ExacTrac system can substantially shorten the positioning and error correction time.

SELECTION OF CITATIONS
SEARCH DETAIL