Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
J. bras. pneumol ; 50(1): e20230233, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1550514

ABSTRACT

ABSTRACT Although lung cancer (LC) is one of the most common and lethal tumors, only 15% of patients are diagnosed at an early stage. Smoking is still responsible for more than 85% of cases. Lung cancer screening (LCS) with low-dose CT (LDCT) reduces LC-related mortality by 20%, and that reduction reaches 38% when LCS by LDCT is combined with smoking cessation. In the last decade, a number of countries have adopted population-based LCS as a public health recommendation. Albeit still incipient, discussion on this topic in Brazil is becoming increasingly broad and necessary. With the aim of increasing knowledge and stimulating debate on LCS, the Brazilian Society of Thoracic Surgery, the Brazilian Thoracic Association, and the Brazilian College of Radiology and Diagnostic Imaging convened a panel of experts to prepare recommendations for LCS in Brazil. The recommendations presented here were based on a narrative review of the literature, with an emphasis on large population-based studies, systematic reviews, and the recommendations of international guidelines, and were developed after extensive discussion by the panel of experts. The following topics were reviewed: reasons for screening; general considerations about smoking; epidemiology of LC; eligibility criteria; incidental findings; granulomatous lesions; probabilistic models; minimum requirements for LDCT; volumetric acquisition; risks of screening; minimum structure and role of the multidisciplinary team; practice according to the Lung CT Screening Reporting and Data System; costs versus benefits of screening; and future perspectives for LCS.


RESUMO O câncer de pulmão (CP) é uma das neoplasias mais comuns e letais no Brasil, e apenas 15% dos pacientes são diagnosticados nos estágios iniciais. O tabagismo persiste como o responsável por mais de 85% de todos os casos. O rastreamento do CP (RCP) por meio da TC de baixa dosagem de radiação (TCBD) reduz a mortalidade do CP em 20%, e, quando combinado com a cessação do tabagismo, essa redução chega a 38%. Na última década, diversos países adotaram o RCP como recomendação de saúde populacional. No Brasil, embora ainda incipiente, a discussão sobre o tema é cada vez mais ampla e necessária. Com o intuito de aumentar o conhecimento e estimular o debate sobre o RCP, a Sociedade Brasileira de Cirurgia Torácica, a Sociedade Brasileira de Pneumologia e Tisiologia e o Colégio Brasileiro de Radiologia e Diagnóstico por Imagem constituíram um painel de especialistas para elaborar as recomendações para o RCP. As recomendações aqui apresentadas foram baseadas em revisão narrativa da literatura, com ênfase em grandes estudos populacionais, em revisões sistemáticas e em recomendações de diretrizes internacionais, sendo construídas após ampla discussão pelo grupo de especialistas. Os temas revisados foram os seguintes: porque rastrear, considerações gerais sobre tabagismo, epidemiologia do CP, critérios de elegibilidade, achados incidentais, lesões granulomatosas, modelos probabilísticos, requisitos mínimos da TCBD, aquisições volumétricas, riscos do rastreamento, estrutura mínima e papel da equipe multidisciplinar, conduta segundo o Lung CT Screening Reporting and Data System (Lung-RADS), custos vs. benefícios e perspectivas do rastreamento.

2.
Radiol. bras ; 56(5): 248-254, Sept.-Oct. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1529316

ABSTRACT

Abstract Objective: To develop a convolutional neural network (CNN) model, trained with the Brazilian "Estudo Longitudinal de Saúde do Adulto Musculoesquelético" (ELSA-Brasil MSK, Longitudinal Study of Adult Health, Musculoskeletal) baseline radiographic examinations, for the automated classification of knee osteoarthritis. Materials and Methods: This was a cross-sectional study carried out with 5,660 baseline posteroanterior knee radiographs from the ELSA-Brasil MSK database (5,660 baseline posteroanterior knee radiographs). The examinations were interpreted by a radiologist with specific training, and the calibration was as established previously. Results: The CNN presented an area under the receiver operating characteristic curve of 0.866 (95% CI: 0.842-0.882). The model can be optimized to achieve, not simultaneously, maximum values of 0.907 for accuracy, 0.938 for sensitivity, and 0.994 for specificity. Conclusion: The proposed CNN can be used as a screening tool, reducing the total number of examinations evaluated by the radiologists of the study, and as a double-reading tool, contributing to the reduction of possible interpretation errors.


Resumo Objetivo: Desenvolver um modelo computacional - rede neural convolucional (RNC) - treinado com radiografias da linha de base do Estudo Longitudinal de Saúde do Adulto Musculoesquelético (ELSA-Brasil Musculoesquelético), para a classificação automática de osteoartrite dos joelhos. Materiais e Métodos: Trata-se de um estudo transversal abrangendo todos os exames da linha de base do ELSA-Brasil Musculoesquelético (5.660 radiografias dos joelhos em incidência posteroanterior). Os exames foram interpretados por médico radiologista com treinamento específico e calibração previamente publicada. Resultados: A RNC desenvolvida apresentou área sob a curva característica de operação do receptor de 0,866 (IC 95%: 0,842-0,882). O modelo pode ser calibrado para alcançar, não simultaneamente, valores máximos de 0,907 para acurácia, 0,938 para sensibilidade e 0,994 para especificidade. Conclusão: A RNC desenvolvida pode ser utilizada como ferramenta de triagem, reduzindo o número total de exames avaliados pelos radiologistas do estudo, e/ou como ferramenta de segunda leitura, contribuindo com a redução de possíveis erros de interpretação.

3.
Radiol. bras ; 53(3): 185-194, May-June 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1136072

ABSTRACT

Abstract In recent decades, there has been a significant increase in the number of imaging examinations performed on pregnant patients. That increase has occurred across the various modalities, including ultrasound, computed tomography, and magnetic resonance imaging. However, little is known about the risks that these examinations generate for the mother and fetus, related to the use of ionizing radiation or the use of contrast media. When pregnant patients are submitted to imaging studies, the principles of protection established by the International Commission on Radiological Protection should always be respected, to avoid injury to the pregnant woman and the fetus. The potential deleterious effects on the fetus must be weighed against the damage caused by not performing an examination that is clearly indicated, given that a delayed or missed diagnosis can be even more harmful to the health of the mother and of the fetus itself. The purpose of this review article is to address concerns regarding the safety of imaging methods used during pregnancy, as well as to identify typical clinical situations that require decisions to be made about the indication and optimal planning of imaging examinations.


Resumo Nas últimas décadas observou-se um aumento expressivo no número de exames de imagem realizados em pacientes gestantes. Este aumento inclui diferentes modalidades, como a ultrassonografia, a tomografia computadorizada e a ressonância magnética. Entretanto, ainda se sabe pouco sobre os riscos que esses exames geram para o binômio mãe-feto, seja no contexto da utilização de radiação ionizante ou da utilização de diferentes meios de contraste. Ao se submeter pacientes grávidas a estudos por imagem, deve-se sempre respeitar os princípios de limitação do uso estabelecidos pela Comissão Internacional de Proteção Radiológica, visando a poupar a gestante e o feto de danos evitáveis. Ressalta-se que os potenciais efeitos deletérios sobre o feto se contrapõem aos danos causados pela não realização de um exame bem indicado, já que um diagnóstico protelado ou perdido pode ser ainda mais nocivo para a saúde materna e do próprio concepto. O objetivo deste artigo de revisão é esclarecer dúvidas sobre a segurança dos métodos de imagem durante o período gestacional, bem como identificar situações clínicas típicas que exigem decisões sobre a indicação e o planejamento otimizado dos exames de imagem.

4.
Rev. bras. reumatol ; 57(2): 154-161, Mar.-Apr. 2017. tab, graf
Article in English | LILACS | ID: biblio-844223

ABSTRACT

Abstract Objective: To describe the performance of a non-fluoroscopic fixed-flexion PA radiographic protocol with a new positioning device, developed for the assessment of knee osteoarthritis (OA) in Brazilian Longitudinal Study of Adult Health Musculoskeletal Study (ELSA-Brasil MSK). Material and methods: A test–retest design including 19 adults (38 knee images) was conducted. Feasibility of the radiographic protocol was assessed by image quality parameters and presence of radioanatomic alignment according to intermargin distance (IMD) values. Repeatability was assessed for IMD and joint space width (JSW) measured at three different locations. Results: Approximately 90% of knee images presented excellent quality. Frequencies of nearly perfect radioanatomic alignment (IMD ≤1 mm) ranged from 29% to 50%, and satisfactory alignment was found in up to 71% and 76% of the images (IMD ≤1.5 mm and ≤1.7 mm, respectively). Repeatability analyses yielded the following results: IMD [SD of mean difference = 1.08; coefficient of variation (%CV) = 54.68%; intraclass correlation coefficient (ICC) (95%CI) = 0.59 (0.34–0.77)]; JSW [SD of mean difference = 0.34–0.61; %CV = 4.48%–9.80%; ICC (95%CI) = 0.74 (0.55–0.85)–0.94 (0.87–0.97)]. Adequately reproducible measurements of IMD and JSW were found in 68% and 87% of the images, respectively. Conclusions: Despite the difficulty in achieving consistent radioanatomic alignment between subsequent radiographs in terms of IMD, the protocol produced highly repeatable JSW measurements when these were taken at midpoint and 10 mm from the medial extremity of the medial tibial plateau. Therefore, measurements of JSW at these locations can be considered adequate for the assessment of knee OA in ELSA-Brasil MSK.


Resumo Objetivo: Descrever o desempenho de um protocolo radiográfico em flexão fixa sem fluoroscopia em incidência PA com um novo posicionador, desenvolvido para a avaliação da osteoartrite de joelho (OA) no estudo ELSA-Brasil ME. Material e métodos: Fez-se um estudo de teste e reteste que incluiu 19 adultos (38 imagens de joelho). A viabilidade do protocolo radiográfico foi avaliada por meio de parâmetros de qualidade da imagem e presença de alinhamento radioanatômico de acordo com as medidas da distância intermarginal (DIM). Avaliaram-se a repetibilidade dos valores de DIM e do espaço articular (EA) em três locais diferentes. Resultados: Aproximadamente 90% das imagens de joelho apresentaram uma qualidade excelente. As frequências de imagens com alinhamento radioanatômico quase perfeito (DIM<1mm) variaram de 29% a 50%, e de alinhamento satisfatório (DIM<1,5mm e <1,7mm) de 71% a 76%, respectivamente. As análises de repetibilidade produziram os seguintes resultados: DIM [DP da média das diferenças = 1,08; coeficiente de variação (% CV) = 54,68%; coeficiente de correlação intraclasse (CCI) (IC 95%) = 0,59 (0,34 a 0,77)]; EA [DP da média das diferenças = 0,34 a 0,61; % CV = 4,48% a 9,80%; CCI (IC 95%) = 0,74 (0,55 a 0,85) a 0,94 (0,87 a 0,97]. Encontraram-se medidas adequadamente reprodutíveis de DIM e EA em 68% e 87% das imagens, respectivamente. Conclusões: Apesar da dificuldade de obter um alinhamento radioanatômico consistente entre radiografias repetidas em termos de DIM, o protocolo produziu medições de EA altamente repetíveis quando essas foram tomadas no ponto médio e a 10 mm da extremidade medial do platô tibial medial. Portanto, as medidas de EA nesses locais podem ser consideradas adequadas para a avaliação da OA de joelho no estudo ELSA-Brasil ME.


Subject(s)
Humans , Male , Female , Adult , Osteoarthritis, Knee/diagnostic imaging , Patient Positioning/instrumentation , Knee Joint/diagnostic imaging , Image Processing, Computer-Assisted , Brazil , Radiography , Radiography/instrumentation , Feasibility Studies , Reproducibility of Results , Longitudinal Studies , Osteoarthritis, Knee/pathology , Middle Aged
5.
Braz. j. phys. ther. (Impr.) ; 20(5): 451-460, Sept.-Oct. 2016. tab
Article in English | LILACS | ID: biblio-828285

ABSTRACT

Abstract Background Health-related control and self-efficacy beliefs can be assessed in the general population using Multidimensional Health Locus of Control-A subscales (MHLC-A) and the General Self-Efficacy Scale (GSES), respectively. Objective To test construct validity, internal consistency, reliability (test-retest) and ceiling and floor effects of Portuguese-Brazil versions of MHLC-A and GSES. Method Civil servants (N=2901) enrolled in a large Brazilian cohort were included. A new version of the GSES was produced (GSES-Brazil). Procedures for cross-cultural adaptation and testing of psychometric properties followed well-accepted international guidelines. Results Confirmatory factor analyses yielded the following indices: MHLC-A (tridimensional model): χ2[df]=223.45[132], p-value <0.01; CFI=0.87; TLI=0.85; RMSEA=0.07 (0.07-0.08); WRMR=3.00. GSES-Brazil (unidimensional model): χ2[df]=788.60[35], p-value <0.01; CFI=0.95; TLI=0.94; RMSEA=0.09 (0.08-0.09); WRMR=2.50. Cronbach’s alpha coefficients and Intraclass Correlation Coefficients (ICC2,1) ranged from 0.57 (0.54-0.59) and 0.57 (0.47-0.65) for MHLC-A internality to 0.80 (0.79-0.81) and 0.71 (0.66-0.77) for GSES-Brazil, respectively. There was no evidence of ceiling and floor effects. Convergent validity analyses provided further support for construct validity of both scales. Conclusion These findings support the use of the newly developed version of GSES-Brazil for the assessment of general self-efficacy of adult Brazilians. Internal consistency was lower than ideal for MHLC-A, indicating these subscales may need further refinements to provide a more psychometrically sound measure of control beliefs.


Subject(s)
Humans , Psychometrics , Socioeconomic Factors , Brazil , Surveys and Questionnaires/standards , Reproducibility of Results
6.
In. Guimarães, Marcos Duarte; Chojniak, Rubens. Oncologia. Rio de Janeiro, Elservier, 2014. p.569-583, ilus, 17, ilusuras.
Monography in Portuguese | LILACS | ID: lil-751097
7.
Radiol. bras ; 43(5): 303-308, set.-out. 2010. ilus
Article in Portuguese | LILACS | ID: lil-568000

ABSTRACT

OBJETIVO: O objetivo deste estudo é demonstrar a importância da enterografia por tomografia computadorizada (entero-TC) e como este exame pode contribuir na elucidação diagnóstica e avaliação clínica de pacientes com doenças do intestino delgado. MATERIAIS E MÉTODOS: Análise retrospectiva de 35 pacientes submetidos a entero-TC realizadas em aparelho multidetector de 16 canais, entre maio de 2008 e março de 2009. Utilizou-se meio de contraste iodado venoso e oral neutro (polietilenoglicol). As principais indicações foram avaliação de doença de Crohn, diarreia de origem indeterminada e suspeita de neoplasias. RESULTADOS: Houve boa correlação dos achados à entero-TC relacionados à atividade da doença em pacientes com doença de Crohn, quando comparados com dados clínicos, laboratoriais e endoscópicos. Em 15 casos identificaram-se alterações compatíveis com doença de Crohn, 9 deles sugerindo atividade. Dos pacientes com diarreia, o exame elucidou a maioria dos casos. Identificaram-se dois casos de tumor carcinoide. CONCLUSÃO: A entero-TC é método simples e eficaz para estudo das doenças inflamatórias/neoplásicas do intestino delgado, sobretudo na avaliação da doença de Crohn, indicando atividade da doença. Uma de suas principais vantagens é a possibilidade de avaliação de alterações mesentéricas e extraintestinais associadas.


OBJECTIVE: The present study was aimed at demonstrating the value of computed tomography enterography (CT enterography) and how this imaging method can be useful in the diagnostic elucidation and assessment of patients with small bowel diseases. MATERIALS AND METHODS: Retrospective evaluation of 35 patients submitted to CT enterography in a 16-row multidetector CT equipment from May/2008 to March/2009. All the patients received intravenous and neutral oral iodinated contrast agents (polyethylene glycol). Main indications were: Crohn's disease, diarrhea of undetermined origin and suspicion of neoplasia. RESULTS: A good correlation was observed between CT enterography findings and clinical, laboratory and endoscopic data related to the disease activity in patients with Crohn's disease. In 15 cases alterations compatible with Crohn's disease were identified, nine of them suggesting disease activity. A diagnosis was achieved in the majority of the patients with diarrhea. Carcinoid tumors were identified in two patients. CONCLUSION: CT enterography is a simple and effective method in the evaluation of inflammatory/neoplastic small bowel diseases, particularly in cases of Crohn's disease, indicating disease activity. One of the main advantages of this method is the possibility of evaluating associated mesenteric and extraintestinal alterations.


Subject(s)
Humans , Male , Female , Young Adult , Middle Aged , Crohn Disease/complications , Crohn Disease/diagnosis , Inflammatory Bowel Diseases/diagnosis , Inflammatory Bowel Diseases/etiology , Intestines/physiopathology , Intestines , Brazil , Diagnostic Imaging , Crohn Disease/pathology , Intestine, Small/pathology , Retrospective Studies , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL