ABSTRACT

Introducción: Mujer de 66 anos portadora de Prótesis biológica en posición mitral que presenta rotura del velo posterior de la válvula protésica a 2 años de su cirugía.


A 66 year old woman with a bioprosthesis in the mitral position presented with a rupture of the posterior leaflet of the prosthetic valve 2 years following surgery.


Subject(s)
Humans , Female , Aged , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Mitral Valve Stenosis/surgery , Rupture, Spontaneous , Bioprosthesis , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve/surgery