Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Rev. chil. obstet. ginecol ; 79(6): 502-507, 2014. graf
Article in Spanish | LILACS | ID: lil-734796

ABSTRACT

Objetivo: Establecer la eficacia diagnóstica de la determinación de gonadotropina coriónica en flujo vaginal para el diagnóstico de la rotura prematura de membranas. Método: Investigación de tipo prospectiva en muestra de 270 embarazadas que asistieron al Hospital Central "Dr. Urquinaona", Maracaibo, Venezuela. Los grupos consistieron en pacientes con rotura prematura de membranas (grupo A; n = 135) y embarazadas con membranas integras (grupo B; n = 135), consideradas como controles. Se evaluaron las características generales, valores de gonadotropina coriónica en flujo vaginal y efectividad diagnóstica. Resultados: La edad gestacional al momento de la determinación de las concentraciones de gonadotropina coriónica en flujo vaginal fue de 32,9 +/- 1,6 semanas para el grupo A y 33,1 +/- 1,9 semanas para el grupo B (p = ns). No se encontraron diferencias estadísticamente significativas en la edad materna y la frecuencia de paridad entre ambos grupos de tratamiento (p = ns). Las pacientes del grupo A presentaron concentraciones significativamente más altas de gonadotropina coriónica en flujo vaginal (697,4 +/- 382,4 mUI/mL) comparado con las embarazadas del grupo B (91,4 +/- 47,1 mUI/mL; p < 0,0001). Un valor de corte de 100 mUI/mL presentó un valor por debajo de la curva de 0,96 con una sensibilidad del 97,0 por ciento, especificidad del 51,1 por ciento, valor predictivo positivo del 66,5 por ciento y valor predictivo negativo del 94,5 por ciento. Conclusión: La determinación de las concentraciones de gonadotropina coriónica en el flujo vaginal es una técnica diagnóstica útil para la rotura prematura de membranas.


Objective: To establish the diagnostical efficacy of chorionic gonadotropin in vaginal fluid determination for diagnosis of premature rupture of membranes. Method: A prospective research type was done with a sample of 270 pregnant women who assisted to obstetrics emergency at Hospital Central "Dr. Urquinaona", Maracaibo, Venezuela. Groups consisted in patients with premature rupture of membranes (group A; n = 135) and pregnant women with intact membranes (group B; n = 135), considered as controls. General characteristics, values of chorionic gonadotropin in vaginal fluid and diagnostic efficacy were evaluated. Results: Gestational age at the moment of determination chorionic gonadotropin in vaginal fluid was 32.9 +/- 1.6 weeks in group A and 33.1 +/- 1.9 weeks in group B (p = ns). There were no significant differences in maternal age and frequency of parity between groups (p = ns). Patients in group A showed significant higher concentrations of chorionic gonadotropin in vaginal fluid (697.4 +/- 382.4 mUI/mL) compared with pregnant women in group B (91.4 +/- 47.1 mUI/mL; p < 0.0001). A cut-off point of 100 mUI/mL showed a under the curve value of 0.96 with a sensitivity of 97.0 percent, specificity of 51.1 percent, positive predictive value of 66.5 percent and negative predictive value of 94.5 percent. Conclusions: Determination of chorionic gonadotropin concentrations in vaginal fluid is a useful diagnosis tool for premature rupture of membranes.


Subject(s)
Humans , Female , Pregnancy , Chorionic Gonadotropin/analysis , Amniotic Fluid/chemistry , Fetal Membranes, Premature Rupture/diagnosis , Biomarkers/analysis , Predictive Value of Tests , Prospective Studies , Sensitivity and Specificity , Vagina
SELECTION OF CITATIONS
SEARCH DETAIL