Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Journal of Biomedical Engineering ; (6): 125-128, 2006.
Article in Chinese | WPRIM | ID: wpr-309869

ABSTRACT

PEG (Mn = 1000)-segmented polyurethanes, with hard segment percentage of 40%, 50% and 55% and named PU-H40, PU-H50 and PU-H55 respectively, were synthesized by bulk polymerization. The structure of PU was characterized by FTIR, DSC, and GPC. Mechanical properties, water contact angles and water vapor transmit rate(WVTR) were also tested. FTIR and DSC showed that the degree of microphase separation increased with the hard content. Mechanical test showed the tensile strength of PU-H50 to be 25 MPa, the highest tensile strength of the PU series. By the use of PEG as soft segment, the surface hydrophilicity of the materials increased dramatically. Owing to its high degree of microphase separation and the mobility of soft segment, the water contact angle of PU-H55 attained to 33 degrees. The WVTRs of PU-H40, PU-H50 and PU-H55 were 789 g/m2/24h, 705 g/m2/24h and 623g/m2/24h respectively. These data suggest that the materials are suitable for fabricating such biomedical articles as surgical gloves, wound dressing and medical protective coating.


Subject(s)
Humans , Biocompatible Materials , Chemistry , Polyethylene Glycols , Chemistry , Polyurethanes , Chemistry , Spectroscopy, Fourier Transform Infrared , Surface Properties
2.
Journal of Biomedical Engineering ; (6): 734-738, 2005.
Article in Chinese | WPRIM | ID: wpr-238353

ABSTRACT

Adopting the two-step method and changing the proportion between PEG (Polyethylene glycol) and PTMG (poly (tetrahydrofuran), we used the MDI (4,4'-diphenylmethane diisocyanate) and short chain extender BDO (1,4-butanediol) as hard segment, the PTMG and PEG as soft segment, and hence prepared a series of polyether-based thermoplastic polyurethanes. FTIR showed the structure character of these polyurethanes. The determination of mechanics property and water contact angles revealed their good mechanics properties and hydrophilicity. Blood compatibility was evaluated by hemolysis test and platelet adhesion test, which revealed their good hemocompatibility. So those polyurethanes may be of wide application in the future.


Subject(s)
Animals , Rabbits , Biocompatible Materials , Chemistry , Butylene Glycols , Chemistry , Isocyanates , Chemistry , Materials Testing , Polyethylene Glycols , Chemistry , Polymers , Chemistry , Polyurethanes , Chemistry
3.
Journal of Biomedical Engineering ; (6): 273-276, 2003.
Article in Chinese | WPRIM | ID: wpr-311057

ABSTRACT

The one-step method was adopted in this study to synthesize aliphatic polyurethane with 4,4-methylene dicyclohexyl diisocyanate(HMDI), 1,4-butanediol (BDO) and poly (tetrahydrofuran) (PTMG). The tests conducted on this material were: FIR spectrum, mechanical properties test, water contact angles test, hemolysis test and platelet adhesion test. Results showed that this material has a good tensile strength up to 30 Mpa, similar to aromaphatic polyurethane. But its tensile elongation, tensile permanent change, hydrophility are better than those of aromaphatic polyurethane. The hemolysis test and platelet adhesion test showed that it has good blood compatibility.


Subject(s)
Animals , Rabbits , Biocompatible Materials , Chemistry , Toxicity , In Vitro Techniques , Materials Testing , Platelet Adhesiveness , Polyurethanes , Chemistry , Toxicity , Spectroscopy, Fourier Transform Infrared , Surface Properties , Tensile Strength
4.
Journal of Biomedical Engineering ; (6): 17-19, 2002.
Article in Chinese | WPRIM | ID: wpr-334340

ABSTRACT

In this article, the blood compatibility of polyurethanes (PUs) made by ourselves for catheters is studied by hemolysis test, platelets adhesion test, kinetic thrombus time test and dynamic clot formation. The results showed that these PUs all have excellent blood compatibility. Among these PUs, H50-100 and H60-100 have best blood compatibility. Additionally, the relationship between the structure and blood compatibility is discussed.


Subject(s)
Animals , Rabbits , Biocompatible Materials , Blood , Blood Coagulation Tests , Catheterization , In Vitro Techniques , Materials Testing , Platelet Function Tests , Polyurethanes
5.
Journal of Biomedical Engineering ; (6): 315-319, 2002.
Article in Chinese | WPRIM | ID: wpr-263600

ABSTRACT

Polyurethanes are popularly used in cardiovascular and other biomedical fields due to their good biocompatibility as well as mechanical properties. But they are subject to biodegradation in vivo for a long time, and cause inflammation, so improving the biocompatibility of medical polyurethanes is an important subject of biomaterials. Recent researches have focused on biological modelling of biomaterials for improving the biocompatibility of polyurethanes. This paper reviews two main methods for improving biocompatibility of polyurethanes-endothelial cells seeding and mimic biomembrane (phospholipid surface), and summarizes the main procedures and questions of these two methods.


Subject(s)
Humans , Biocompatible Materials , Chemistry , Endothelial Cells , Phospholipids , Chemistry , Polyurethanes , Chemistry
SELECTION OF CITATIONS