Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Fisioter. pesqui ; 21(3): 217-222, Jul-Sep/2014. tab
Article in English | LILACS | ID: lil-728751

ABSTRACT

Scientific articles about reliability of photogrammetry for cervical spine posture evaluation are infrequent. The aim of the present investigation is to verify intra- and inter-examiner reliability of computerized photogrammetry method for head postural evaluation in lateral view. Twenty-five young women between 20 and 30 years old were positioned seated in an upright position and photographed in lateral view. The photographs were imported to Corel Draw X13 program for postural evaluation by computerized photogrammetry. The reliability of intra- and inter-examiner analyses were performed for the angles: condyle-acromion (ACA), menton-sternum (AME) and Frankfurt (AF). The photogrammetry was performed by two examiners: EA and EB. The EA performed analysis of the photos of participants twice (A1 and A2) for the same angles in a range of three months to assess intra-examiner reliability. The EB performed the photogrammetry for the same angles (B1) for comparison with the data from EA (inter-examiner analysis). Excellent correlation in the intra-examiner analysis (A1 and A2) was found for the angles: ACA and AME, both with a 1.0 interclass correlation coefficient (ICC); for the AF angle, it was found ICC=0.78. For the ICC inter-examiner between A1 and B1, it was observed: ACA (ICC=0.24), AME (ICC=0.26), and AF (ICC=0.00). For the comparison between A2 and B1 the ICC values were: 0.23; 0.27; and 0.00, respectively for ACA, AME and AF, classified as weak correlations. The photogrammetry is reliable when performed by the same examiner. The inter-examiner assess showed low reliability, what could have been compromised by the reduced experience of the EB in applying the method.


La literatura acerca de la fiabilidad de la fotogrametría para la evaluación postural cervical es escasa. El objetivo de este estudio es verificar la fiabilidad intra e interexaminador de la fotogrametría computadorizada para la evaluación postural de la cabeza en vista lateral. Veinticinco mujeres jóvenes fueron posicionadas sentadas con la espalda recta, y fotografiadas en vista lateral. Las fotografías fueron importadas por el programa Corel Draw X3 para la evaluación postural mediante fotogrametría computadorizada. Los análisis de fiabilidad intra e interexaminadores se realizaron para los ángulos: cóndilo acromion (ACA),mentoesternal (AME) y Frankfurt (AF). La fotogrametría fue realizada por dos examinadores: EA y EB. Para el análisis intraexaminadores el EA hizo la evaluación de las fotos de las participantes por dos veces (A1 y A2) para los mismos ángulos en un intervalo de tres meses. Para el análisis interexaminadores el EB evaluó la fotogrametría de los mismos ángulos (B1) y se la comparó con los datos del EA. Hubo una excelente correlación en el análisis intraexaminador (A1 y ​​A2) con coeficiente de correlación intraclase (ICC) de 1,0 para los ángulos ACA y AME y 0,78 para AF. Hubo débil correlación en el análisis interevaluadores A1 y ​​B1 con ICC=0,24 y 0,26; y entre A2 y B1 con ICC=0,23; 0,27 y 0,00 para los ángulos ACA, AME y AF, respectivamente. Se concluye que la fotogrametría es fiable cuando se realiza por el mismo evaluador. La evaluación interexaminador mostró baja fiabilidad, lo que puede haber sido comprometida por la limitada experiencia de EB en la aplicación del método.


A literatura sobre confiabilidade da fotogrametria para avaliação postural cervical é escassa. O objetivo do presente estudo é verificar a confiabilidade intra e interexaminador da fotogrametria computadorizada para avaliação postural da cabeça em vista lateral. Vinte e cinco mulheres jovens foram posicionadas sentadas com a coluna ereta e fotografadas em vista lateral. As fotografias foram importadas pelo programa Corel Draw X3 para avaliação postural por fotogrametria computadorizada. As análises de confiabilidade intra e interexaminadores foram realizadas para os ângulos: côndilo-acrômio (ACA), mento-esternal (AME) e Frankfurt (AF). A fotogrametria foi realizada por dois examinadores: EA e EB. Para a análise intraexaminadores o EA fez a avaliação das fotos das participantes por duas vezes (A1 e A2) para os mesmos ângulos em um intervalo de três meses. Para a análise interexaminadores o EB avaliou a fotogrametria dos mesmos ângulos (B1), que foi comparada com os dados do EA. Houve correlação excelente na análise intraexaminador (A1 e A2) com coeficiente de correlação intraclasse (CCI) de 1,0 para os ângulos ACA e AME e 0,78 para AF. Houve fraca correlação na análise interavaliadores A1 e B1 com CCI=0,24 e 0,26; e entre A2 e B1 com CCI=0,23; 0,27 e 0,00 para os ângulos ACA, AME e AF, respectivamente. Conclui-se que a fotogrametria é confiável quando realizada pelo mesmo avaliador. A avaliação interexaminador apresentou baixa confiabilidade, o que pode ter sido comprometida pela reduzida experiência do EB na aplicação do método.


Subject(s)
Humans , Female , Young Adult , Photogrammetry , Physical Therapy Modalities , Posture , Reproducibility of Results , /methods , Women
2.
Fisioter. pesqui ; 21(1): 34-39, Jan-Mar/2014. tab
Article in English | LILACS | ID: lil-709707

ABSTRACT

Scientific articles about reliability of photogrammetry for cervical spine posture evaluation are infrequent. The aim of the present investigation is to verify intra-and inter-examiner reliability of the computerized photogrammetry method for head postural evaluation in lateral view. Twenty-five young women, between 20 and 30 years old, were positioned seated in an upright position and photographed in lateral view. The photographs were imported to Corel Draw X13 program for postural evaluation by computerized photogrammetry. Analyses of intra-and inter-examiner reliability were performed for the angles: condyle-acromion (ACA), menton-sternum (AME) and Frankfurt (AF). The photogrammetry was performed by two examiners: EA and EB. For intra-examiner analyses, EA assessed the pictures twice (A1 and A2) for the same angles within 3 months. For the inter-examiner analyses, EB performed the photogrammetry for the same angles (B1) in order to compare with the data from EA. Using the interclass correlation coefficient (ICC) we observed an excellent correlation in the intra-examiner analysis (A1 and A2) for the angles: ACA and AME (both with ICC=1.0); and AF (ICC=0.78). For the inter-examiner analyses between A1 and B1, it was observed: ACA (ICC=0.24), AME (ICC=0.26) and AF (ICC=0.00). For the comparison between A2 and B1, the ICC values were: 0.23; 0.27 and 0.00, respectively for ACA, AME and AF, classified as weak correlations. In conclusion, the photogrammetry is reliable when performed by the same examiner. The inter-examiner assess showed low reliability, what could have been compromised by the reduced experience of the EB in applying the method...


La literatura acerca de la confiabilidad de la fotogrametría para la evaluación postural cervical es escasa. El objetivo del presente estudio es verificar la confiabilidad inter e intra-examinador de la fotogrametría computadorizada para la evaluación postural de la cabeza en la vista lateral. Veinticinco mujeres jóvenes fueron posicionadas sentadas con la columna erecta y fotografiadas en la vista lateral. Las fotografías fueron importadas por el programa Corel Draw X3 para la evaluación postural mediante fotogrametría computadorizada. Los análisis de confiabilidad intra e inter-examinadores fueron realizadas para los ángulos: cóndilo acromión (ACA), mentón esternón (AME) y Frankfurt (AF). La fotogrametría era realizada por dos examinadores: EA y EB. Para el análisis intra-examinador, el EA hizo la evaluación de las fotos de las participantes dos veces (A1 y A2) para los mismos ángulos un intervalo de tres meses. Para el análisis inter-examinador, el EB evaluó la fotogrametría de los mismos ángulos (B1), la cual se comparó con los datos del EA. Evaluándose el coeficiente de correlación inter-clase (CCI), se observó que hubo una correlación excelente en el análisis intra-examinador (A1 y A2 ) con CCI=1,0 para los ángulos ACA y AME y CCI=0,78 para AF. Hubo una correlación débil en el análisis inter-evaluadores A1 y B1 con un CCI de 0,24 y 0,26 y entre A2 y B1 con CCI de 0,23; 0,27 y 0,00 para los ángulos de la ACA , AME y AF, respectivamente. Se concluye que la fotogrametría es confiable cuando se realiza por el mismo evaluador. La evaluación inter-examinador mostró baja confiabilidad, lo que puede haber sido comprometido por la experiencia reducida experiencia del EB en la aplicación del método...


A literatura sobre confiabilidade da fotogrametria para avaliação postural cervical é escassa. O objetivo do presente estudo é verificar a confiabilidade inter e intraexaminador da fotogrametria computadorizada para a avaliação postural da cabeça em vista lateral. Vinte e cinco mulheres jovens foram posicionadas sentadas com a coluna ereta e fotografadas em vista lateral. As fotografias foram importadas pelo programa Corel Draw X3 para a avaliação postural por fotogrametria computadorizada. As análises de confiabilidade intra e interexaminadores foram realizadas para os ângulos: côndilo-acrômio (ACA), mento-esternal (AME) e de Frankfurt (AF). A fotogrametria foi realizada por dois examinadores: EA e EB. Para a análise intraexaminadores o EA fez a avaliação das fotos das participantes duas vezes (A1 e A2) para os mesmos ângulos em um intervalo de três meses. Para a análise interexaminadores o EB avaliou a fotogrametria dos mesmos ângulos (B1), que foi comparada com os dados do EA. Avaliando o coeficiente de correlação interclasse (CCI), observamos que houve correlação excelente na análise intraexaminador (A1 e A2) com CCI=1,0 para os ângulos ACA e AME e CCI=0,78 para AF. Houve fraca correlação na análise interavaliadores A1 e B1 com CCI de 0,24 e 0,26 e entre A2 e B1 com CCI de 0,23; 0,27 e 0,00 para os ângulos ACA, AME e AF, respectivamente. Conclui-se que a fotogrametria é confiável quando realizada pelo mesmo avaliador. A avaliação interexaminador apresentou baixa confiabilidade, o que pode ter sido comprometida pela reduzida experiência do EB na aplicação do método...


Subject(s)
Humans , Female , Adult , Photogrammetry , Posture , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL