Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Int. braz. j. urol ; 38(2): 258-266, Mar.-Apr. 2012. ilus, tab
Article in English | LILACS | ID: lil-623341

ABSTRACT

INTRODUCTION AND OBJECTIVES: The mini sling concept for stress urinary incontinence is an anatomical approach that involves placing a midurethral low-tension tape anchored to the obturator internus muscles bilaterally. They overcome the blind passage of long needles and all the related complications. There are many different devices available and because these are outpatient procedures, primary fixation plays an important role in the outcome. The objective is to evaluate the primary fixation of the various devices of attachment of the commercially available mini-slings through biomechanical tests. MATERIALS AND METHODS: A total of 45 Wistar rats were divided in 3 groups of 15 rats each. They underwent 5 subcutaneous implantation of different mini slings and one polipropilene mesh (control), as follows: TVT-Secur® (Gynecare, USA), Type 1 polypropylene mesh (control); Ophira Mini Sling System® (Promedon, Argentina), Tissue Fixation System® (TFS PTY, Australia), Zipper Sling® and "T device" (Prosurg, USA). The abdominal wall was removed on bloc at different times after implant for biomechanical evaluation, which consisted in application of unidirectional force to the extremity of the fixation system or mesh, until it was completely removed from the tissue using a tension meter (Nexygen 3.0 Universal Testing Machine - LLOYD Instruments). The force was measured in Newtons (N). RESULTS: There was significant difference in the resistance to extraction among the different fixation systems. At 7 days the Ophira Mini Sling System® presented the best fixation and "T dispositive" the worst. CONCLUSION: Ophira mini sling System® presented the best primary fixation at 7º, 14º and 30º days. The impact of this feature in the clinical setting needs to be verified.


Subject(s)
Animals , Rats , Suburethral Slings , Urethra/surgery , Urinary Incontinence, Stress/surgery , Analysis of Variance , Biomechanical Phenomena , Materials Testing , Polypropylenes , Prosthesis Implantation/methods , Rats, Wistar , Treatment Outcome , Urologic Surgical Procedures/methods
2.
Acta ortop. bras ; 13(1): 28-30, 2005. tab
Article in Portuguese | LILACS | ID: lil-400825

ABSTRACT

Na cirurgia de reconstrução do ligamento cruzado anterior do joelho, os enxertos de tendões autólogos são a principal opção como substitutos ligamentares. Entretanto, uma das razões da falha da reconstrução ligamentar com tecidos moles é o estiramento ou elongamento do enxerto com o tempo. Neste trabalho, foram ensaiados oito tendões do músculo grácil e oito do músculo semitendinoso humanos, obtidos de quatro cadáveres do sexo masculino, com idade média de 24,5 anos. Cada tendão foi submetido a uma deformação relativa constante de 2,5 por cento durante 600 s, com registro contínuo do relaxamento de força. A seguir, o tendão retornava ao seu comprimento inicial e era mantido num período de repouso de 300 s. Após este intervalo, um segundo ensaio, semelhante ao primeiro, era realizado. A velocidade de carregamento empregada foi de 10 por cento do comprimento inicial do corpo de prova por segundo. Foram obtidos valores de força inicial, com 300 s e 600 s nos dois ensaios. A análise estatística sugere um comportamento mecânico mais uniforme para o tendão do músculo semitendinoso quando comparado ao tendão do músculo grácil.


Subject(s)
Humans , Male , Adult , Anterior Cruciate Ligament , Anterior Cruciate Ligament/anatomy & histology , Reflex, Stretch , Knee
SELECTION OF CITATIONS
SEARCH DETAIL