Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chinese Critical Care Medicine ; (12): 1037-1038, 2019.
Article in Chinese | WPRIM | ID: wpr-754105

ABSTRACT

At present, most of the common medical clothes in clinic are uniform medical clothes, but there is no special clothes for patients in intensive care unit (ICU). In recent years, with the extensive application of critical ultrasound in the field of critical medicine, it is obviously difficult to meet the clinical needs on traditional patients' clothes. Guangdong Provincial People's Hospital designed a patient's clothing for critical ultrasound examination. The left/right chest, lateral chest, groin and abdomen of the patient's clothing body were covered with cloth and marked areas. When critically ill patients need to be examined by ultrasound and electrocardiogram, the site can be quickly located only by removing the cloth. At the same time, it can protect patients' privacy, avoid aggravating the condition due to cold, increase patients' comfort in clothing, and also facilitate medical care. It is worthy popularizing in clinic because of its practicability and novel design.

2.
China Pharmacy ; (12): 199-203, 2018.
Article in Chinese | WPRIM | ID: wpr-704551

ABSTRACT

OBJECTIVE:To investigate risk factors of multidrug-resistant organisms (MDROs) infection in elderly patients of ICU,and to provide reference for formulation and implementation of MDROs prevention and control measures.METHODS:A total of 146 elderly patients were selected from ICU of our hospital during Dec.2013-Jun.2016.Throat swab,sputum swab and anal swab specimens (1 copy,respectively) were collected to conduct active screening of MRSA and ESBLs-producing Enterobacteriaceae.Risk factors of MDROs infection,pathogen distribution and drug resistance were analyzed.RESULTS:Among samples of 146 patients,there were 34 MRSA positive samples in throat swab with positive rate of 23.3%;there were 30 MRSA positive samples in sputum swab with positive rate of 20.5%;there were 99 ESBLs-producing bacteria positive samples in anal swab (containing 50 ESBLs-producing Escherichia coli positive samples and 49 ESBLs-producing Klebsiella pneumoniae positive samples) with positive rate of 67.8%.The positive rate of throat swab MRSA screening was not correlated with patient's gender,age,tracheal intubation or mechanical ventilation (P>0.05),but it was related with hospitalization time in ICU (P<0.05).The positive rate of sputum swab MRSA screening was not correlated with patient' s gender,tracheal intubation or mechanical ventilation;the positive rate of anal swab ESBLs-producing bacteria screening were not related with patient's gender(P>0.05).But they were related with age and hospitalization time in ICU (P<0.05).Compared with negative patients,there was no statistical significance in the times of fiberoptic bronchoscopy in throat/sputum swab MRSA screening positive patients (P>0.05).The times of enema,the times of bladder irrigation,the times of urethral catheterization and the duration of indwelling catheter in anal swab ESBLs-producing bacteria screening positive patients were significantly more or longer than negative patients,with statistical significance (P<0.05).Binary Logistic regression analysis showed that hospitalization time in ICU was risk factor of positive active screening of throat swab in elderly patients of ICU[OR=1.119,95 % CI (1.071,1.385),P=0.021];age was risk factor of positive active screening of sputum swab[OR=1.893,95 % CI (1.232,4.042),P=0.032];age and hospitalization time in ICU were risk factors of positive active screening of anal swab [OR were 1.046,1.022,95%CI were (1.005,1.088) (1.006,3.283),P were 0.027,0.031].A total of 163 strains of MDROs were detected,among which there were 64 strains of MRSA,50 strains of ESBLs-producing E.coli and 49 strains of ESBLs-producing K.pneumoniae.They were generally highly resistant to compound preparation containing enzyme inhibitors.CONCLUSIONS:The results of MDROs active screening in elderly patients of ICU are related with age,hospitalization time in ICU,the times of enema,the times of bladder irrigation,the times of urethral catheterization and the duration of indwelling catheter.Age and hospitalization time in ICU were risk factors of MDROs infection.The pathogens are mainly ESBLs-producing Enterobacteriaceae,and drug resistance is severe.For elderly critical patients with MDROs infection,clinical prevention and intervention measures should be taken to prevent and control the prevalence and spread of MDROs in ICU.

3.
Chinese Critical Care Medicine ; (12): 727-730, 2018.
Article in Chinese | WPRIM | ID: wpr-703704

ABSTRACT

Objective To investigate the predictive value of central venous-to-arterial carbon dioxide difference (Pcv-aCO2) on the prognosis of elderly patients with sepsis.Methods 208 elderly patients who met the diagnostic criteria of the Sepsis-3 and with the age of more than 60 years old, and admitted to intensive care unit (ICU) of Guangdong General Hospital from January to December in 2017 were enrolled. According to the prognosis, the patients were divided into death group (n = 46) and survival group (n = 162). The Pcv-aCO2, central venous oxygen saturation (ScvO2), serum procalcitonin (PCT), C-reactive protein (CRP), sequential organ failure assessment (SOFA) and acute physiology and chronic health evaluationⅡ (APACHEⅡ) were collected for all patients. The differences of each index between the two groups were compared. The correlations between Pcv-aCO2 and ScvO2, PCT, CRP, SOFA, APACHEⅡscores were analyzed respectively with Pearson correlation. The prognostic value of Pcv-aCO2 in elderly patients with sepsis was assessed by receiver operating characteristic curve (ROC).Results Compared with survival group, the Pcv-aCO2, PCT, CRP, SOFA and APACHEⅡscores in death group were significantly increased [Pcv-aCO2 (mmHg, 1 mmHg = 0.133 kPa): 6.13±3.33 vs. 4.40±2.65, PCT (μg/L): 31.41±12.83 vs. 3.01±2.69, CRP (mg/L): 130.51± 42.23 vs. 104.46±50.12, SOFA: 12.01±2.25 vs. 9.05±2.06, APACHEⅡ: 29.52±5.03 vs. 20.01±3.21, allP < 0.05], and ScvO2 in death group was significantly decreased (0.571±0.136 vs. 0.685±0.106,P < 0.01). Correlation analysis showed that the Pcv-aCO2 was negatively correlated with ScvO2 (r = -0.762,P = 0.001) and was positively correlated with PCT, CRP, SOFA and APACHEⅡscores (r value was 0.737, 0.625, 0.738, 0.713, respectively, allP < 0.05). ROC curve analysis showed that the area under the ROC curve (AUC) of Pcv-aCO2 prediction of death in patients with sepsis was 0.826, the cut-off was 6.62 mmHg, the sensitivity was 84.7%, the specificity was 77.5%, the positive likelihood ratio was 3.76, and the negative likelihood ratio was 0.19.Conclusion Pcv-aCO2 has a great value in evaluating the prognosis of elderly patients with sepsis and can accurately determine the prognosis of sepsis.

4.
Chinese Journal of Internal Medicine ; (12): 397-417, 2018.
Article in Chinese | WPRIM | ID: wpr-710071

ABSTRACT

Critical ultrasonography(CUS) is different from the traditional diagnostic ultrasound,the examiner and interpreter of the image are critical care medicine physicians.The core content of CUS is to evaluate the pathophysiological changes of organs and systems and etiology changes.With the idea of critical care medicine as the soul,it can integrate the above information and clinical information,bedside real-time diagnosis and titration treatment,and evaluate the therapeutic effect so as to improve the outcome.CUS is a traditional technique which is applied as a new application method.The consensus of experts on critical ultrasonography in China released in 2016 put forward consensus suggestions on the concept,implementation and application of CUS.It should be further emphasized that the accurate and objective assessment and implementation of CUS requires the standardization of ultrasound image acquisition and the need to establish a CUS procedure.At the same time,the standardized training for CUS accepted by critical care medicine physicians requires the application of technical specifications,and the establishment of technical specifications is the basis for the quality control and continuous improvement of CUS.Chinese Critical Ultrasound Study Group and Critical Hemodynamic Therapy Collabration Group,based on the rich experience of clinical practice in critical care and research,combined with the essence of CUS,to learn the traditional ultrasonic essence,established the clinical application technical specifications of CUS,including in five parts:basic view and relevant indicators to obtain in CUS;basic norms for viscera organ assessment and special assessment;standardized processes and systematic inspection programs;examples of CUS applications;CUS training and the application of qualification certification.The establishment of applied technology standard is helpful for standardized training and clinical correct implementation.It is helpful for clinical evaluation and correct guidance treatment,and is also helpful for quality control and continuous improvement of CUS application.

5.
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care ; (6): 565-569, 2017.
Article in Chinese | WPRIM | ID: wpr-663036

ABSTRACT

Objective To investigate the effect of Simo decoction oral liquid on inflammatory in acute respiratory distress syndrome (ARDS) mouse serum and the bronchoalveolar lavage fluid (BALF) and to explore the mechanism.Methods Fifty BALB/c mice were divided into normal control group, ARDS model group, small, moderate and large dose Simo decoction oral liquid-treated groups (simplified as Simo groups) according to random number table method (n=10, in each group). The ARDS model mice were replicated by lipopolysaccharide (LPS) tracheal instillation, and the mice in normal control group were given the same amount of normal saline. Immediately after the success of modeling, the mice were gavaged with 1, 2, 4 times the equivalent dose Simo decoction oral liquid of 7.56 mL·kg-1·d-1 in small, moderate or large dose Simo groups respectively, and there was no intervention in the normal control group or ARDS model group. All the mice were sacrificed at 24 hours after the respective drug amount or normal saline was given in various groups. The lung samples were taken for histologic evaluation, and BALF and serum samples were analyzed for the tumor necrosis factor-α(TNF-α), interleukin (IL-1β, IL-6), and in the mean time the level of serum superoxide dismutase (SOD) was detected.Results The pathological observation of lung tissue showed: there was no obvious inflammatory exudation in lung tissue of mice in normal control group; the inflammatory exudation in lung tissue of mice was increased significantly, the level of TNF-α (ng/L: 1759±303 vs. 104±27, 2506±674 vs. 507±46), IL-1β(ng/L: 209±16 vs. 114±11, 7325±826 vs. 3513±498) and IL-6 (ng/L: 144±38 vs. 47±7, 126±38 vs. 15±7) in serum and BALF were significantly increased, and the content of SOD (kU/L: 40.26±2.54 vs. 50.68±3.75) in serum was significantly decreased in ARDS model group (allP < 0.05), indicating that animal model of ARDS was set up successfully. Compared with ARDS model group, in small, moderate and large dose Simo groups, the inflammation exudation in lung tissue of mouse was reduced, the levels of TNF-α, IL-1βand IL-6 in serum and BALF were reduced, and the content of SOD in serum was increased [serum: TNF-α(ng/L) was 1642±276, 1126±154, 817±102 vs. 1759±303, IL-1β(ng/L)was 198±12, 170±11, 141±13 vs. 209±16, IL-6 (ng/L) was 127±22, 82±16, 41±15 vs. 144±38, SOD (kU/L) was 42.11±1.64, 48.09±1.23 vs. 40.26±2.54; BALF: TNF-α(ng/L) was 2479±446, 1632±330, 1067±223 vs. 2506±674, IL-1β(ng/L): 6939±725, 5398±625, 4401±210 vs. 7325±826, IL-6 (ng/L): 106±30, 68±13, 34±10 vs. 126±38, allP < 0.05], showing the Simo decoction inhibiting the lung inflammation and the above levels of indexes inserum and BALF was in a dose-dependent manner, and the changes in large dose Simo group was the most significant 45.18±1.15, .Conclusions Simo decoction oral liquid can inhibit the inflammatory response of ARDS, reduce the oxidative stress and decrease the lung injury of mice with ARDS.

SELECTION OF CITATIONS
SEARCH DETAIL